Malte Rieken
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Malte Rieken has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Nicole Ebinger Mundorff
Department of Urology, University Hospital Basel, Spitalstrasse 21, 4031 Basel, Switzerland
2 shared publicationsStephen Wyler
Department of Urology, University Hospital Basel, Spitalstrasse 21, 4031 Basel, Switzerland
2 shared publicationsA. Bachmann
Universitätsspital Basel
1 shared publicationAlexander Bachmann
University Hospital Basel
1 shared publication- Alexander Bachmann
Department of Urology, University Hospital Basel, Basel, Switzerland
1 shared publication C. Gratzke
Campus Großhadern, Klinikum der Universität München, Ludwig-Maximilians-Universität München
1 shared publication
Latest Publications
- 28 September 2013
- Published by Springer Nature in World Journal of Urology
- Vol. 32 (4) , 881-890
Innovations in diagnostic imaging of localized prostate cancer
In recent years, various imaging modalities have been developed to improve diagnosis, staging, and localization of early-stage prostate cancer (PCa). A MEDLINE literature search of the time frame between 01/2007 and 06/2013 was performed on imaging of localized PCa. Conventional transrectal ultrasound (TRUS) is mainly used to guide prostate biopsy. Contrast-enhanced ultrasound is based on the assumption that PCa tissue is hypervascularized and might be better identified after intravenous injection of a microbubble contrast agent. However, results on its additional value for cancer detection are controversial. Computer-based analysis of the transrectal ultrasound signal (C-TRUS) appears to detect cancer in a high rate of patients with previous biopsies. Real-time elastography seems to have higher sensitivity, specificity, and positive predictive value than conventional TRUS. However, the method still awaits prospective validation. The same is true for prostate histoscanning, an ultrasound-based method for tissue characterization. Currently, multiparametric MRI provides improved tissue visualization of the prostate, which may be helpful in the diagnosis and targeting of prostate lesions. However, most published series are small and suffer from variations in indication, methodology, quality, interpretation, and reporting. Among ultrasound-based techniques, real-time elastography and C-TRUS seem the most promising techniques. Multiparametric MRI appears to have advantages over conventional T2-weighted MRI in the detection of PCa. Despite these promising results, currently, no recommendation for the routine use of these novel imaging techniques can be made. Prospective studies defining the value of various imaging modalities are urgently needed.
- 28 September 2013
- Published by Springer Nature in World Journal of Urology
- Vol. 32 (4) , 881-890
Innovations in diagnostic imaging of localized prostate cancer
In recent years, various imaging modalities have been developed to improve diagnosis, staging, and localization of early-stage prostate cancer (PCa). A MEDLINE literature search of the time frame between 01/2007 and 06/2013 was performed on imaging of localized PCa. Conventional transrectal ultrasound (TRUS) is mainly used to guide prostate biopsy. Contrast-enhanced ultrasound is based on the assumption that PCa tissue is hypervascularized and might be better identified after intravenous injection of a microbubble contrast agent. However, results on its additional value for cancer detection are controversial. Computer-based analysis of the transrectal ultrasound signal (C-TRUS) appears to detect cancer in a high rate of patients with previous biopsies. Real-time elastography seems to have higher sensitivity, specificity, and positive predictive value than conventional TRUS. However, the method still awaits prospective validation. The same is true for prostate histoscanning, an ultrasound-based method for tissue characterization. Currently, multiparametric MRI provides improved tissue visualization of the prostate, which may be helpful in the diagnosis and targeting of prostate lesions. However, most published series are small and suffer from variations in indication, methodology, quality, interpretation, and reporting. Among ultrasound-based techniques, real-time elastography and C-TRUS seem the most promising techniques. Multiparametric MRI appears to have advantages over conventional T2-weighted MRI in the detection of PCa. Despite these promising results, currently, no recommendation for the routine use of these novel imaging techniques can be made. Prospective studies defining the value of various imaging modalities are urgently needed.
- 23 February 2013
- Published by Springer Nature in Der Urologe
- Vol. 52 (3) , 339-344
Laservaporisation der Prostata
- 23 February 2013
- Published by Springer Nature in Der Urologe
- Vol. 52 (3) , 339-344
Laservaporisation der Prostata
- 31 December 2012
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 45 (1) , 28-33
The effect of increased maximum power output on perioperative and early postoperative outcome in photoselective vaporization of the prostate
Preclinical studies suggest an increased vaporization rate and speed of the 532 nm 180-W XPS GreenLight laser (180-W) compared with the 120-W HPS GreenLight laser (120-W) and the 80-W PV GreenLight laser (80-W). To test the clinical relevance of this observation we analyzed intraoperative data and early postoperative results after photoselective vaporization of the prostate (PVP) with the 180-W, 120-W, and 80-W laser. A retrospective pair-to-pair comparison was performed including 80 consecutive patients who underwent PVP for the treatment of benign prostate enlargement with the 180-W, 120-W, and 80-W laser. The groups matched concerning age, prostate volume, PSA-value, and preoperative catheterization. Primary study outcome measurement was PSA-value reduction at 3 months; intraoperative data, perioperative complications, and early postoperative functional course were secondary study outcome measurements. Energy application per case (kJ), preoperative prostate volume (kJ/ml) operating time (kJ/minute), and lasing time (kJ/minute) was significantly higher with the 180-W laser. Prevalence of impaired visibility due to bleeding was comparable between the 180-W and the 120-W laser but significantly lower with 80-W. Duration of hospitalization was shorter with the 180-W laser compared to the former laser systems. During the postoperative course of 3 months voiding parameters and micturition symptoms significantly improved in all groups, the incidence of postoperative dysuria was comparable. Postoperative PSA-value reduction was significantly higher after treatment with the 180-W laser. With the 180-W laser, higher energy application and higher speed of tissue vaporization leads to increased tissue vaporization compared to the former 120-W and 80-W laser systems. Clinical efficacy and perioperative safety are maintained with the higher powered laser.
- 31 December 2012
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 45 (1) , 28-33
The effect of increased maximum power output on perioperative and early postoperative outcome in photoselective vaporization of the prostate
Preclinical studies suggest an increased vaporization rate and speed of the 532 nm 180-W XPS GreenLight laser (180-W) compared with the 120-W HPS GreenLight laser (120-W) and the 80-W PV GreenLight laser (80-W). To test the clinical relevance of this observation we analyzed intraoperative data and early postoperative results after photoselective vaporization of the prostate (PVP) with the 180-W, 120-W, and 80-W laser. A retrospective pair-to-pair comparison was performed including 80 consecutive patients who underwent PVP for the treatment of benign prostate enlargement with the 180-W, 120-W, and 80-W laser. The groups matched concerning age, prostate volume, PSA-value, and preoperative catheterization. Primary study outcome measurement was PSA-value reduction at 3 months; intraoperative data, perioperative complications, and early postoperative functional course were secondary study outcome measurements. Energy application per case (kJ), preoperative prostate volume (kJ/ml) operating time (kJ/minute), and lasing time (kJ/minute) was significantly higher with the 180-W laser. Prevalence of impaired visibility due to bleeding was comparable between the 180-W and the 120-W laser but significantly lower with 80-W. Duration of hospitalization was shorter with the 180-W laser compared to the former laser systems. During the postoperative course of 3 months voiding parameters and micturition symptoms significantly improved in all groups, the incidence of postoperative dysuria was comparable. Postoperative PSA-value reduction was significantly higher after treatment with the 180-W laser. With the 180-W laser, higher energy application and higher speed of tissue vaporization leads to increased tissue vaporization compared to the former 120-W and 80-W laser systems. Clinical efficacy and perioperative safety are maintained with the higher powered laser.
- 6 January 2010
- Published by Springer Nature in World Journal of Urology
- Vol. 28 (1) , 53-62
Complications of laser prostatectomy: a review of recent data
Laser techniques for the treatment of bladder outlet obstruction (BOO) due to benign prostate enlargement (BPE) have emerged as an alternative to transurethral resection of the prostate (TURP) and open prostatectomy (OP). A Medline search over the past 4 years was performed to assess the safety, intra- and postoperative morbidity of various laser techniques. Data on holmium laser enucleation of the prostate (HoLEP) show the highest grade of evidence with two meta-analyses available and prove the low intra- and postoperative morbidity with reproducible long-term results. Photoselective vaporization of the prostate (PVP) with the Greenlightlaser (potassium titanyl phosphate, KTP or lithium borate, LBO) is characterized by excellent haemostatic properties in patients with or without oral anticoagulation. Long-term results show a reoperation rate comparable with TURP; however, there is a lack of randomized trials. Various types of diode lasers with different wavelengths are available for laser vaporization; despite their favourable haemostatic properties, a higher invasion depth seems to result in necrosis of the tissue leading to a higher rate of reoperation. Thulium-laser resection of the prostate shows promising intra- and postoperative morbidity, but data are limited and initial results need to be confirmed in large-scale trials. In summary, HoLEP- and KTP-, or LBO-laser vaporization of the prostate are the most mature techniques of laser prostatectomy and treatment alternatives to TURP and OP, whereas the clinical value and durability of procedures with diode laser systems and the thulium laser need to be confirmed in high-quality prospective RCTs.
- 6 January 2010
- Published by Springer Nature in World Journal of Urology
- Vol. 28 (1) , 53-62
Complications of laser prostatectomy: a review of recent data
Laser techniques for the treatment of bladder outlet obstruction (BOO) due to benign prostate enlargement (BPE) have emerged as an alternative to transurethral resection of the prostate (TURP) and open prostatectomy (OP). A Medline search over the past 4 years was performed to assess the safety, intra- and postoperative morbidity of various laser techniques. Data on holmium laser enucleation of the prostate (HoLEP) show the highest grade of evidence with two meta-analyses available and prove the low intra- and postoperative morbidity with reproducible long-term results. Photoselective vaporization of the prostate (PVP) with the Greenlightlaser (potassium titanyl phosphate, KTP or lithium borate, LBO) is characterized by excellent haemostatic properties in patients with or without oral anticoagulation. Long-term results show a reoperation rate comparable with TURP; however, there is a lack of randomized trials. Various types of diode lasers with different wavelengths are available for laser vaporization; despite their favourable haemostatic properties, a higher invasion depth seems to result in necrosis of the tissue leading to a higher rate of reoperation. Thulium-laser resection of the prostate shows promising intra- and postoperative morbidity, but data are limited and initial results need to be confirmed in large-scale trials. In summary, HoLEP- and KTP-, or LBO-laser vaporization of the prostate are the most mature techniques of laser prostatectomy and treatment alternatives to TURP and OP, whereas the clinical value and durability of procedures with diode laser systems and the thulium laser need to be confirmed in high-quality prospective RCTs.