Shao‐Xiang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shao‐Xiang Zhang has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Pheng-Ann Heng
The Chinese University of Hong Kong, Shatin, Hong Kong
5 shared publications K. Li
Department of Anatomy, Third Military Medical University, Chongqing, People’s Republic of China
3 shared publicationsKai Li
Department of Anatomy, Third Military Medical University, Chongqing, People's Republic of China
3 shared publicationsL.-W. Tan
Department of Anatomy, Third Military Medical University, Chongqing, People’s Republic of China
3 shared publicationsM.-G. Qiu
Department of Anatomy, Third Military Medical University, Chongqing, People’s Republic of China
3 shared publicationsQ.-Y. Li
Department of Anatomy, Third Military Medical University, Chongqing, People’s Republic of China
3 shared publications
Latest Publications
- 1 July 2011
- Published by International College of Surgeons in International Surgery
- Vol. 96 (3) , 274-280
A Novel Technique for Three-Dimensional Reconstruction for Surgical Simulation Around the Craniocervical Junction Region
Performing surgeries on the craniocervical junction presents a technical challenge for operating surgeons. Three-dimensional (3D) reconstruction and surgical simulation have improved the efficacy and success rate of surgeries. The aim of this study was to create a 3D, digitized visible model of the craniocervical junction region to help realize accurate simulation of craniocervical surgery on a graphic workstation. Transverse sectional anatomy data for the study were chosen from the first Chinese visible human. Manual axial segmentation of the skull base, cervical spine, cerebellum, vertebral artery, internal carotid artery, sigmoid sinus, internal jugular vein, brain stem, and spinal cord were carried out by using Photoshop software. The segmented structures were reconstructed in 3 dimensions with surface and volume rendering to accurately display 3D models spatially. In contrast to conventional 3D reconstruction techniques that are based on computed tomography and magnetic resonance imaging Digital Imaging and Communications in Medicine (DICOM) inputs and provide mostly osseous details, this technique can help to illustrate the surrounding soft tissue structure and provide a realistic surgical simulation. The reconstructed 3D model was successfully used in simulating complex procedures in the virtual environment, including the transoral approach, bone drillings, and clivus resection.
- 1 July 2011
- Published by International College of Surgeons in International Surgery
- Vol. 96 (3) , 274-280
A Novel Technique for Three-Dimensional Reconstruction for Surgical Simulation Around the Craniocervical Junction Region
Performing surgeries on the craniocervical junction presents a technical challenge for operating surgeons. Three-dimensional (3D) reconstruction and surgical simulation have improved the efficacy and success rate of surgeries. The aim of this study was to create a 3D, digitized visible model of the craniocervical junction region to help realize accurate simulation of craniocervical surgery on a graphic workstation. Transverse sectional anatomy data for the study were chosen from the first Chinese visible human. Manual axial segmentation of the skull base, cervical spine, cerebellum, vertebral artery, internal carotid artery, sigmoid sinus, internal jugular vein, brain stem, and spinal cord were carried out by using Photoshop software. The segmented structures were reconstructed in 3 dimensions with surface and volume rendering to accurately display 3D models spatially. In contrast to conventional 3D reconstruction techniques that are based on computed tomography and magnetic resonance imaging Digital Imaging and Communications in Medicine (DICOM) inputs and provide mostly osseous details, this technique can help to illustrate the surrounding soft tissue structure and provide a realistic surgical simulation. The reconstructed 3D model was successfully used in simulating complex procedures in the virtual environment, including the transoral approach, bone drillings, and clivus resection.
- 22 October 2008
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 31 (2) , 129-138
A comparative study of thin-layer cross-sectional anatomic morphology and CT images of the basal cistern and its application in acute craniocerebral traumas
Aim To compare the cross-sectional morphologic features of successive thin-layers and CT images of the basal cistern and its application in the diagnosis and management of acute craniocerebral traumas. Materials and methods Successive thin-layer cross-sectional images of the basal cistern were retrieved from the second Chinese visible human (CVH) data set and observed. A total of 40 healthy volunteers were subjected to 64-slice spiral CT scan of the head, and CT images of the basal cistern were compared with CVH images. A total of 413 patients with acute craniocerebral traumas were subjected to 64-slice spiral CT scan of the head, CT image changes of the basal cistern were observed. Results Thin-layer cross-sectional images retrieved from the CVH data set clearly displayed the sectional anatomic morphology, morphologic change pattern and important adjacent structures of the basal cistern. The quadrigeminal cistern was pateriform or sellaeform; the suprasellar cistern was hexagonal or pentagonal star-shaped; the ambient cistern encircled both sides of the brainstem like an arc band. CT images of the quadrigeminal and ambient cisterns were similar with their CVH images; however, the morphology of the suprasellar cistern changed substantially. In 413 patients with acute craniocerebral traumas, the basal cistern may be normal, or presented with narrowing, obliteration, shift, hematocele, and pneumatosis. Narrowing or obliteration of the basal cistern occurred mostly at the side of dominant intracranial lesions, and frequently occurred in patients with diffuse axonal injury or combination of SDH + CONT + ICH. Conclusions Thin-layer cross-sectional images of the basal cistern retrieved from the CVH data set correspond satisfactorily to CT images of the basal cistern. Comparison of the two types of images can provide a sectional anatomic basis for the image identification of acute craniocerebral traumas. A careful observation on the initial CT images of the basal cistern for anatomic morphologic changes will help diagnose acute craniocerebral traumas early, improve the management, and appropriately predict the prognosis of the condition.
- 22 October 2008
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 31 (2) , 129-138
A comparative study of thin-layer cross-sectional anatomic morphology and CT images of the basal cistern and its application in acute craniocerebral traumas
Aim To compare the cross-sectional morphologic features of successive thin-layers and CT images of the basal cistern and its application in the diagnosis and management of acute craniocerebral traumas. Materials and methods Successive thin-layer cross-sectional images of the basal cistern were retrieved from the second Chinese visible human (CVH) data set and observed. A total of 40 healthy volunteers were subjected to 64-slice spiral CT scan of the head, and CT images of the basal cistern were compared with CVH images. A total of 413 patients with acute craniocerebral traumas were subjected to 64-slice spiral CT scan of the head, CT image changes of the basal cistern were observed. Results Thin-layer cross-sectional images retrieved from the CVH data set clearly displayed the sectional anatomic morphology, morphologic change pattern and important adjacent structures of the basal cistern. The quadrigeminal cistern was pateriform or sellaeform; the suprasellar cistern was hexagonal or pentagonal star-shaped; the ambient cistern encircled both sides of the brainstem like an arc band. CT images of the quadrigeminal and ambient cisterns were similar with their CVH images; however, the morphology of the suprasellar cistern changed substantially. In 413 patients with acute craniocerebral traumas, the basal cistern may be normal, or presented with narrowing, obliteration, shift, hematocele, and pneumatosis. Narrowing or obliteration of the basal cistern occurred mostly at the side of dominant intracranial lesions, and frequently occurred in patients with diffuse axonal injury or combination of SDH + CONT + ICH. Conclusions Thin-layer cross-sectional images of the basal cistern retrieved from the CVH data set correspond satisfactorily to CT images of the basal cistern. Comparison of the two types of images can provide a sectional anatomic basis for the image identification of acute craniocerebral traumas. A careful observation on the initial CT images of the basal cistern for anatomic morphologic changes will help diagnose acute craniocerebral traumas early, improve the management, and appropriately predict the prognosis of the condition.
- 27 February 2006
- Published by Wiley in Clinical Anatomy
- Vol. 19 (3) , 204-215
Chinese visible human project
Research on the digital visible human is of great significance and has considerable application value. The US visible human project created the first digital image dataset of a complete human (one male and one female) in 1995. To promote worldwide application‐oriented visible human research, additional visible human datasets, representative of different populations of the world, are needed. The Chinese visible human (CVH) male (created in October 2002) and female (created in February 2003) Project achieved greater integrity of images, better blood vessel identification, and were free of organic disease. The most noteworthy technical advance of the Chinese visible human project (CVHP) was the construction of a low temperature laboratory, which prevented loss of small structures (including teeth, nasal conchae, and articular cartilage) from the milling surface. Thus, better integrity of images was achieved. To date, we have acquired five CVH datasets and volume rendered them for visualization on a PC. 3D reconstruction of some organs and structures has been completed and work to segment a complete dataset is under way. Although there is still a long way to go to make the visible human meet the application‐oriented needs in various fields, progress is being made toward acquiring new datasets, performing segmentation, and setting up a platform of computer‐assisted medicine. Here, we review the history and highlights of the CVHP and foresee its future development as well. Clin. Anat. 19:204–215, 2006.
- 27 February 2006
- Published by Wiley in Clinical Anatomy
- Vol. 19 (3) , 204-215
Chinese visible human project
Research on the digital visible human is of great significance and has considerable application value. The US visible human project created the first digital image dataset of a complete human (one male and one female) in 1995. To promote worldwide application‐oriented visible human research, additional visible human datasets, representative of different populations of the world, are needed. The Chinese visible human (CVH) male (created in October 2002) and female (created in February 2003) Project achieved greater integrity of images, better blood vessel identification, and were free of organic disease. The most noteworthy technical advance of the Chinese visible human project (CVHP) was the construction of a low temperature laboratory, which prevented loss of small structures (including teeth, nasal conchae, and articular cartilage) from the milling surface. Thus, better integrity of images was achieved. To date, we have acquired five CVH datasets and volume rendered them for visualization on a PC. 3D reconstruction of some organs and structures has been completed and work to segment a complete dataset is under way. Although there is still a long way to go to make the visible human meet the application‐oriented needs in various fields, progress is being made toward acquiring new datasets, performing segmentation, and setting up a platform of computer‐assisted medicine. Here, we review the history and highlights of the CVHP and foresee its future development as well. Clin. Anat. 19:204–215, 2006.
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005 (1094687X) , 4168-4170
Chinese Visible Human Project: Dataset Acquisition and Its Primary Applications
The research on digital visible human is of great significance and application value. The US Visible Human Project (VHP) created the first digital image data set of a complete human (one male and one female) in 1995. To promote a worldwide application-oriented VHR, more visible human data sets representative of different populations of the world are in demand. The Chinese Visible Human (CVH) male (created in Oct. 2002) and female (created in Feb. 2003) project achieved greater integrity of images, easier blood vessel identification, and were free of organic lesion. The most noteworthy technical advance of CVH Project was the construction of a low temperature laboratory, which contributed to the prevention of small structures (including teeth, concha nasalis, and articular cartilage) from falling off out of the milling surface. Thus, better integrity of images can be ensured. So far, we have achieved an acquisition of five CVH data sets and the corresponding volume visualization on PC. The 3D reconstruction of some organs or structures has been finished. The work of segmentation on a complete data set is still on-going
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005 (1094687X) , 4168-4170
Chinese Visible Human Project: Dataset Acquisition and Its Primary Applications
The research on digital visible human is of great significance and application value. The US Visible Human Project (VHP) created the first digital image data set of a complete human (one male and one female) in 1995. To promote a worldwide application-oriented VHR, more visible human data sets representative of different populations of the world are in demand. The Chinese Visible Human (CVH) male (created in Oct. 2002) and female (created in Feb. 2003) project achieved greater integrity of images, easier blood vessel identification, and were free of organic lesion. The most noteworthy technical advance of CVH Project was the construction of a low temperature laboratory, which contributed to the prevention of small structures (including teeth, concha nasalis, and articular cartilage) from falling off out of the milling surface. Thus, better integrity of images can be ensured. So far, we have achieved an acquisition of five CVH data sets and the corresponding volume visualization on PC. The 3D reconstruction of some organs or structures has been finished. The work of segmentation on a complete data set is still on-going
- 9 December 2004
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 27 (2) , 113-118
Thin sectional anatomy, three-dimensional reconstruction and visualization of the heart from the Chinese Visible Human
The research aimed to provide sectional anatomic and three-dimensional (3D) virtual anatomic bases for imaging diagnosis and surgical operation by the use of data from the heart of the first Chinese digitized Visible Human. Data from the series of thin sections of the heart were analyzed and input into an SGI workstation, and 3D reconstruction and virtualization of the heart were performed. Each image of sectional anatomy was clear and the 3D structures of the heart were reconstructed in their entirety. All reconstructed structures can be displayed by multiple structural and color modes, individually or jointly, and can be rotated continuously in any plane. The model of the virtual heart clearly showed fine structures of the heart in random orientation. The dataset of the sectional anatomy provides a fine and integrated morphologic base for imaging diagnosis. The 3D reconstructed images clearly show the internal and entire structures of the heart.
- 9 December 2004
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 27 (2) , 113-118
Thin sectional anatomy, three-dimensional reconstruction and visualization of the heart from the Chinese Visible Human
The research aimed to provide sectional anatomic and three-dimensional (3D) virtual anatomic bases for imaging diagnosis and surgical operation by the use of data from the heart of the first Chinese digitized Visible Human. Data from the series of thin sections of the heart were analyzed and input into an SGI workstation, and 3D reconstruction and virtualization of the heart were performed. Each image of sectional anatomy was clear and the 3D structures of the heart were reconstructed in their entirety. All reconstructed structures can be displayed by multiple structural and color modes, individually or jointly, and can be rotated continuously in any plane. The model of the virtual heart clearly showed fine structures of the heart in random orientation. The dataset of the sectional anatomy provides a fine and integrated morphologic base for imaging diagnosis. The 3D reconstructed images clearly show the internal and entire structures of the heart.
- 5 August 2004
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 26 (5) , 411-416
The pre-styloid compartment of the parapharyngeal space: a three-dimensional digitized model based on the Chinese Visible Human
- 5 August 2004
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 26 (5) , 411-416
The pre-styloid compartment of the parapharyngeal space: a three-dimensional digitized model based on the Chinese Visible Human
- Open Access
- 25 February 2004
- Published by Wiley in Journal of Anatomy
- Vol. 204 (3) , 165-173
The Chinese Visible Human (CVH) datasets incorporate technical and imaging advances on earlier digital humans
We report the availability of a digitized Chinese male and a digitzed Chinese female typical of the population and with no obvious abnormalities. The embalming and milling procedures incorporate three technical improvements over earlier digitized cadavers. Vascular perfusion with coloured gelatin was performed to facilitate blood vessel identification. Embalmed cadavers were embedded in gelatin and cryosectioned whole so as to avoid section loss resulting from cutting the body into smaller pieces. Milling performed at −25 °C prevented small structures (e.g. teeth, concha nasalis and articular cartilage) from falling off from the milling surface. The male image set (.tiff images each of 36 Mb) has a section resolution of 3072 × 2048 pixels (∼170 µm, the accompanying magnetic resonance imaging and computer tomography data have a resolution of 512 × 512, i.e. ∼440 µm). The Chinese Visible Human male and female datasets are available at http://www.chinesevisiblehuman.com. (The male is 90.65 Gb and female 131.04 Gb). MPEG videos of direct records of real‐time volume rendering are at: http://www.cse.cuhk.edu.hk/~crc
- 25 February 2004
- Published by Wiley in Journal of Anatomy
- Vol. 204 (3) , 165-173
Open AccessThe Chinese Visible Human (CVH) datasets incorporate technical and imaging advances on earlier digital humans
We report the availability of a digitized Chinese male and a digitzed Chinese female typical of the population and with no obvious abnormalities. The embalming and milling procedures incorporate three technical improvements over earlier digitized cadavers. Vascular perfusion with coloured gelatin was performed to facilitate blood vessel identification. Embalmed cadavers were embedded in gelatin and cryosectioned whole so as to avoid section loss resulting from cutting the body into smaller pieces. Milling performed at −25 °C prevented small structures (e.g. teeth, concha nasalis and articular cartilage) from falling off from the milling surface. The male image set (.tiff images each of 36 Mb) has a section resolution of 3072 × 2048 pixels (∼170 µm, the accompanying magnetic resonance imaging and computer tomography data have a resolution of 512 × 512, i.e. ∼440 µm). The Chinese Visible Human male and female datasets are available at http://www.chinesevisiblehuman.com. (The male is 90.65 Gb and female 131.04 Gb). MPEG videos of direct records of real‐time volume rendering are at: http://www.cse.cuhk.edu.hk/~crc
- Open Access
- 12 November 2003
- Published by Wiley in The Anatomical Record Part B: The New Anatomist
- Vol. 275B (1) , 190-195
Creation of the Chinese visible human data set
The United States Visible Human Project (VHP) created a digital image data set of complete human male (data acquisition finished in November 1994) and female (data acquisition finished in December 1995) cadavers in magnetic resonance imaging (MRI), computed tomography (CT), and anatomical (anatomic serial section) modes. VHP aroused worldwide enthusiasm for Visible Human Research (VHR), and the data set is being used in a variety of research and educational domains. The Visible Korean Human (VKH) male was produced in March 2001. To accelerate worldwide VHR and to promote virtual anatomy as a revolutionary break with conventional anatomy, more visible human data sets representative of different populations of the world are in demand. The Chinese Visible Human (CVH) male (created in October 2002) and female (created in February 2003) project achieved greater integrity of images, easier blood vessel identification, and were free of organic lesion (unlike the other visible human projects). We performed data acquisition, three‐dimensional (3D) reconstruction, and visualization with improved technology to create CVH male and female. CVH is the first volumetric data representing a complete normal adult human male and female of an Asian population. This article presents the history of Chinese Visible Human cadavers and the methods and technology used to produce the data set. Anat Rec (Part B: New Anat) 275B:190–195, 2003.
- 12 November 2003
- Published by Wiley in The Anatomical Record Part B: The New Anatomist
- Vol. 275B (1) , 190-195
Open AccessCreation of the Chinese visible human data set
The United States Visible Human Project (VHP) created a digital image data set of complete human male (data acquisition finished in November 1994) and female (data acquisition finished in December 1995) cadavers in magnetic resonance imaging (MRI), computed tomography (CT), and anatomical (anatomic serial section) modes. VHP aroused worldwide enthusiasm for Visible Human Research (VHR), and the data set is being used in a variety of research and educational domains. The Visible Korean Human (VKH) male was produced in March 2001. To accelerate worldwide VHR and to promote virtual anatomy as a revolutionary break with conventional anatomy, more visible human data sets representative of different populations of the world are in demand. The Chinese Visible Human (CVH) male (created in October 2002) and female (created in February 2003) project achieved greater integrity of images, easier blood vessel identification, and were free of organic lesion (unlike the other visible human projects). We performed data acquisition, three‐dimensional (3D) reconstruction, and visualization with improved technology to create CVH male and female. CVH is the first volumetric data representing a complete normal adult human male and female of an Asian population. This article presents the history of Chinese Visible Human cadavers and the methods and technology used to produce the data set. Anat Rec (Part B: New Anat) 275B:190–195, 2003.
- 22 October 2003
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 26 (2) , 149-152
Visualization of the temporal bone of the Chinese Visible Human
- 22 October 2003
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 26 (2) , 149-152
Visualization of the temporal bone of the Chinese Visible Human
- 1 December 1992
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 196-198, 908-911
Edge plasma phenomena of the low density plasma to high density transition in the HL-1 tokamak
- 1 December 1992
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 196-198, 908-911
Edge plasma phenomena of the low density plasma to high density transition in the HL-1 tokamak