Edward P. Gerstenfeld
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Edward P. Gerstenfeld has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Babak Nazer
Electrophysiology Section, Knight Cardiovascular Institute, Oregon Health and Sciences University, Portland, Oregon
6 shared publicationsSrikant Duggirala
From the Electrophysiology Section, Division of Cardiology, Department of Medicine, University of California San Francisco
4 shared publications- Yasuaki Tanaka
Cardiovascular Center, Yokosuka Kyosai Hospital, Yokosuka, Japan
3 shared publications Bieito Campos
Electrophysiology Section, Department of Cardiology, Hospital Universitari Arnau de Vilanova, Lleida, Spain
2 shared publicationsGevorg Stepanyan
Division of Cardiology, Department of Medicine, University of California, San Francisco, 500 Parnassus Avenue, MU, San Francisco, CA, 94143, USA
2 shared publicationsJeffrey Olgin
Section of Cardiac Electrophysiology, Department of Medicine, University of California, San Francisco, San Francisco, California
2 shared publications
Latest Publications
- 9 March 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (7) , 1071-1072
Cardiac autonomic neuromodulation: Can "kilohertz frequency" reduce arrhythmia frequency?
- 9 March 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (7) , 1071-1072
Cardiac autonomic neuromodulation: Can "kilohertz frequency" reduce arrhythmia frequency?
- 1 March 2017
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 10 (3) , e004760
Feasibility of Rapid Linear-Endocardial and Epicardial Ventricular Ablation Using an Irrigated Multipolar Radiofrequency Ablation Catheter
Background—: A common strategy for ablation of scar-based ventricular tachycardia is delivering multiple lesions in a linear pattern. Methods and Results—: We tested the efficacy of a novel linear irrigated multipolar ablation catheter capable of creating linear lesions with a single application. Healthy swine underwent endocardial and epicardial linear ablation using a novel linear irrigated ablation catheter; control animals underwent focal lesions in a linear pattern over 3.5 cm with an irrigated radiofrequency catheter. The linear catheter contained 7 irrigated electrodes spaced over 3.5 cm and could deliver ≤25 W to each electrode. Linear ablation required significantly less radiofrequency time than focal ablation (56±11 versus 497±110 seconds; P P 3 ; P =0.002). There was no difference between linear (n=22) and focal (n=7) endocardial line length or volume. Gaps (length 2.8±0.9 mm) were present in 53% of focal lines and 0% of linear ablation lines. No perforations, steam pops, or thrombus were noted. Conclusions—: Compared with sequential focal radiofrequency ablation in a linear pattern, an irrigated multipolar linear ablation catheter safely delivers contiguous endocardial or epicardial lesions without gaps in a single ablation. This catheter shows promise for decreasing ventricular tachycardia ablation procedure time and improving outcome.
- 1 March 2017
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 10 (3) , e004760
Feasibility of Rapid Linear-Endocardial and Epicardial Ventricular Ablation Using an Irrigated Multipolar Radiofrequency Ablation Catheter
Background—: A common strategy for ablation of scar-based ventricular tachycardia is delivering multiple lesions in a linear pattern. Methods and Results—: We tested the efficacy of a novel linear irrigated multipolar ablation catheter capable of creating linear lesions with a single application. Healthy swine underwent endocardial and epicardial linear ablation using a novel linear irrigated ablation catheter; control animals underwent focal lesions in a linear pattern over 3.5 cm with an irrigated radiofrequency catheter. The linear catheter contained 7 irrigated electrodes spaced over 3.5 cm and could deliver ≤25 W to each electrode. Linear ablation required significantly less radiofrequency time than focal ablation (56±11 versus 497±110 seconds; P P 3 ; P =0.002). There was no difference between linear (n=22) and focal (n=7) endocardial line length or volume. Gaps (length 2.8±0.9 mm) were present in 53% of focal lines and 0% of linear ablation lines. No perforations, steam pops, or thrombus were noted. Conclusions—: Compared with sequential focal radiofrequency ablation in a linear pattern, an irrigated multipolar linear ablation catheter safely delivers contiguous endocardial or epicardial lesions without gaps in a single ablation. This catheter shows promise for decreasing ventricular tachycardia ablation procedure time and improving outcome.
- 1 February 2016
- Published by Elsevier in Heart Rhythm
- Vol. 13 (2) , 547-554
Diffuse fibrosis leads to a decrease in unipolar voltage: Validation in a swine model of premature ventricular contraction–induced cardiomyopathy
- 1 February 2016
- Published by Elsevier in Heart Rhythm
- Vol. 13 (2) , 547-554
Diffuse fibrosis leads to a decrease in unipolar voltage: Validation in a swine model of premature ventricular contraction–induced cardiomyopathy
- 1 December 2015
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (6) , 1491-1497
Epicardial Catheter Ablation Using High-Intensity Ultrasound
Background—: Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, while sparing superficial structures. We developed and tested an epicardial HIU ablation catheter in a closed chest, in vivo swine model. Methods and Results—: The HIU catheter is an internally cooled, 14-French, side-facing catheter, integrated with A-mode ultrasound guidance. Swine underwent percutaneous subxyphoid epicardial access and ablation with HIU (n=10 swine) at 15, 20, and 30 W. Compared with irrigated radiofrequency lesions in control swine (n = 5), HIU demonstrated increased lesion depth (HIU 11.6±3.2 mm versus radiofrequency 4.7±1.6 mm; mean±SD) and epicardial sparing (HIU 2.9±2.1 mm versus radiofrequency 0.1±0.2 mm) at all HIU powers, and increased lesion volume at HIU 20 and 30 W ( P <0.0001 for all comparisons). HIU ablation over coronary arteries and surrounding epicardial fat resulted in deep lesions with normal angiographic flow. Histological disruption of coronary adventitia, but not media or intima, was noted in 44% of lesions. Conclusions—: Compared with radiofrequency, HIU ablation in vivo demonstrates significantly deeper and larger lesions with greater epicardial sparing in a dose-dependent manner. Further development of this catheter may lead to a promising alternative to epicardial radiofrequency ablation.
- 1 December 2015
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (6) , 1491-1497
Epicardial Catheter Ablation Using High-Intensity Ultrasound
Background—: Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, while sparing superficial structures. We developed and tested an epicardial HIU ablation catheter in a closed chest, in vivo swine model. Methods and Results—: The HIU catheter is an internally cooled, 14-French, side-facing catheter, integrated with A-mode ultrasound guidance. Swine underwent percutaneous subxyphoid epicardial access and ablation with HIU (n=10 swine) at 15, 20, and 30 W. Compared with irrigated radiofrequency lesions in control swine (n = 5), HIU demonstrated increased lesion depth (HIU 11.6±3.2 mm versus radiofrequency 4.7±1.6 mm; mean±SD) and epicardial sparing (HIU 2.9±2.1 mm versus radiofrequency 0.1±0.2 mm) at all HIU powers, and increased lesion volume at HIU 20 and 30 W ( P <0.0001 for all comparisons). HIU ablation over coronary arteries and surrounding epicardial fat resulted in deep lesions with normal angiographic flow. Histological disruption of coronary adventitia, but not media or intima, was noted in 44% of lesions. Conclusions—: Compared with radiofrequency, HIU ablation in vivo demonstrates significantly deeper and larger lesions with greater epicardial sparing in a dose-dependent manner. Further development of this catheter may lead to a promising alternative to epicardial radiofrequency ablation.
- 2 September 2015
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (11) , 1333-1342
Importance of Ventricular Tachycardia Induction and Mapping for Patients Referred for Epicardial Ablation
Many nonischemic cardiomyopathy (NICMP) patients referred for catheter ablation of ventricular tachycardia (VT) undergo an initial epicardial approach under general anesthesia (GA). However, GA may suppress inducibility and decrease tolerance of induced VT, leaving substrate modification as the sole ablation method. Determine the utility of a strategy of initial programmed electrical stimulation (PES) under light sedation in patients referred for epicardial ablation of VT. Of 68 NICMP patients referred for VT ablation, 25 were referred specifically for epicardial ablation. All patients underwent PES under conscious sedation, with conversion to GA and epicardial access only if VT morphology and/or endocardial mapping suggested an epicardial substrate. VT was induced with PES in 24 of 25 patients (mean age 52 years; 76% male; ejection fraction 38 ± 18%). VT was hemodynamically tolerated in 63% and unstable in 38% of patients. The noninducible/unstable VT patients underwent substrate modification based on voltage and pace mapping. Of the patients with stable VT, 73% were mapped and ablated endocardially (six right ventricle, three left ventricle, one left coronary cusp, one middle cardiac vein), and 33% were successfully ablated in areas of normal endocardial voltage. After ablation, the clinical VT was noninducible in all patients. After mean follow-up of 10 months, 80% were free of implantable cardioverter defibrillator shocks or sustained VT. An initial approach of PES and entrainment mapping under conscious sedation is critically important for patients with NICMP referred for epicardial ablation. Empiric ablation of endocardial/epicardial scar would have missed the clinical VT in 20% of patients.
- 2 September 2015
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (11) , 1333-1342
Importance of Ventricular Tachycardia Induction and Mapping for Patients Referred for Epicardial Ablation
Many nonischemic cardiomyopathy (NICMP) patients referred for catheter ablation of ventricular tachycardia (VT) undergo an initial epicardial approach under general anesthesia (GA). However, GA may suppress inducibility and decrease tolerance of induced VT, leaving substrate modification as the sole ablation method. Determine the utility of a strategy of initial programmed electrical stimulation (PES) under light sedation in patients referred for epicardial ablation of VT. Of 68 NICMP patients referred for VT ablation, 25 were referred specifically for epicardial ablation. All patients underwent PES under conscious sedation, with conversion to GA and epicardial access only if VT morphology and/or endocardial mapping suggested an epicardial substrate. VT was induced with PES in 24 of 25 patients (mean age 52 years; 76% male; ejection fraction 38 ± 18%). VT was hemodynamically tolerated in 63% and unstable in 38% of patients. The noninducible/unstable VT patients underwent substrate modification based on voltage and pace mapping. Of the patients with stable VT, 73% were mapped and ablated endocardially (six right ventricle, three left ventricle, one left coronary cusp, one middle cardiac vein), and 33% were successfully ablated in areas of normal endocardial voltage. After ablation, the clinical VT was noninducible in all patients. After mean follow-up of 10 months, 80% were free of implantable cardioverter defibrillator shocks or sustained VT. An initial approach of PES and entrainment mapping under conscious sedation is critically important for patients with NICMP referred for epicardial ablation. Empiric ablation of endocardial/epicardial scar would have missed the clinical VT in 20% of patients.
- 1 September 2015
- Published by Elsevier in Progress in Cardiovascular Diseases
- Vol. 58 (2) , 202-212
Atrial Fibrillation Ablation: Indications, Emerging Techniques, and Follow-Up
- 1 September 2015
- Published by Elsevier in Progress in Cardiovascular Diseases
- Vol. 58 (2) , 202-212
Atrial Fibrillation Ablation: Indications, Emerging Techniques, and Follow-Up
- 1 August 2015
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 1 (4) , 245-247
Should All Patients Be Started on Antiarrhythmic Drugs After Atrial Fibrillation Ablation?
- 1 August 2015
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 1 (4) , 245-247
Should All Patients Be Started on Antiarrhythmic Drugs After Atrial Fibrillation Ablation?
- 1 January 2015
- Published by Elsevier in Heart Rhythm
- Vol. 12 (1) , 144-154
Utility of high-resolution electroanatomic mapping of the left ventricle using a multispline basket catheter in a swine model of chronic myocardial infarction
- 1 January 2015
- Published by Elsevier in Heart Rhythm
- Vol. 12 (1) , 144-154
Utility of high-resolution electroanatomic mapping of the left ventricle using a multispline basket catheter in a swine model of chronic myocardial infarction
- 3 October 2014
- Published by Elsevier in Heart Rhythm
- Vol. 12 (1) , 95-103
Use of a novel fragmentation map to identify the substrate for ventricular tachycardia in postinfarction cardiomyopathy
- 3 October 2014
- Published by Elsevier in Heart Rhythm
- Vol. 12 (1) , 95-103
Use of a novel fragmentation map to identify the substrate for ventricular tachycardia in postinfarction cardiomyopathy