Bernd Trathnigg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bernd Trathnigg has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Imran Malik
H.E.J. Research Institute of Chemistry, International Center for Chemical and Biological Sciences (ICCBS), University of Karachi, Karachi 75270, Pakistan
6 shared publications Hasnat Ahmed
Institute of Chemistry, Karl-Franzens-University, Central Polymer Laboratory/Molecular Characteristics (CePol/MC), Graz, Austria
5 shared publicationsNguyen Viet Cuong
Institute of Chemistry, Karl-Franzens-University, Central Polymer Laboratory/Molecular Characteristics (CePol/MC), Graz, Austria. Fax: +43-3163809840
3 shared publicationsAlexei Gorbunov
Institute for Highly Pure Biopreparations, Pudozhskaya 7, 197110 St.Petersburg, Russia
2 shared publicationsNguyen V. Cuong
Institute of Chemistry, Karl-Franzens-University, Central Polymer Laboratory/Molecular Characteristics, Graz, Austria
2 shared publicationsOtto Jamelnik
2 shared publications
Latest Publications
- 1 February 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1329, 98-106
Discrimination of block structures in liquid adsorption chromatography of polymers. Simulation and experiment
- 1 February 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1329, 98-106
Discrimination of block structures in liquid adsorption chromatography of polymers. Simulation and experiment
- 30 December 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (8) , 2577-2586
Analysis of polyethyleneoxide macromonomers by liquid chromatography along the critical adsorption line
Polyoxyethylene macromonomers are analyzed by one-dimensional liquid chromatography under different conditions, depending on the required information. These samples may contain polyethylene glycol (PEG) and the corresponding di(meth)acrylate besides the desired mono(meth)acrylate. The molar mass distribution (MMD) of the PEG and the monoester can be obtained by liquid adsorption chromatography (LAC) on a reversed-phase column in acetone–water with a gradient from 10% to 20% acetone. The MMD of the diesters can be obtained with isocratic elution by liquid chromatography at critical conditions (LCCC) on a reversed-phase column in 31% acetone, or using size-exclusion conditions for PEG and LAC conditions for the end groups, which is the case in 40–55% acetone. The absolute amount of the series with different functionality can be obtained by LCCC in ternary mobile phases consisting of acetone, methanol, and water along the critical adsorption line. Under such conditions, all series elute as narrow peaks (regardless their MMD), which can easily be integrated and quantified.
- 30 December 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (8) , 2577-2586
Analysis of polyethyleneoxide macromonomers by liquid chromatography along the critical adsorption line
Polyoxyethylene macromonomers are analyzed by one-dimensional liquid chromatography under different conditions, depending on the required information. These samples may contain polyethylene glycol (PEG) and the corresponding di(meth)acrylate besides the desired mono(meth)acrylate. The molar mass distribution (MMD) of the PEG and the monoester can be obtained by liquid adsorption chromatography (LAC) on a reversed-phase column in acetone–water with a gradient from 10% to 20% acetone. The MMD of the diesters can be obtained with isocratic elution by liquid chromatography at critical conditions (LCCC) on a reversed-phase column in 31% acetone, or using size-exclusion conditions for PEG and LAC conditions for the end groups, which is the case in 40–55% acetone. The absolute amount of the series with different functionality can be obtained by LCCC in ternary mobile phases consisting of acetone, methanol, and water along the critical adsorption line. Under such conditions, all series elute as narrow peaks (regardless their MMD), which can easily be integrated and quantified.
- 1 December 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (8) , 2531-2537
Characterization of polyoxyethylenes according to the number of hydroxy end groups by hydrophilic interaction chromatography at critical conditions for polyethylene glycol
Polyoxyethylenes with different functionality and architecture can be separated according to the number of terminal hydroxy groups on polar stationary phases in acetone water mobile phases containing 90–97% acetone. The best results were obtained on a HILIC column. Typical samples, which can be analyzed by this technique, are polyethylene glycols, their mono- and dialkyl ethers, macromonomers, the fatty esters of PEG, and ethoxylated glycerol.
- 1 December 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (8) , 2531-2537
Characterization of polyoxyethylenes according to the number of hydroxy end groups by hydrophilic interaction chromatography at critical conditions for polyethylene glycol
Polyoxyethylenes with different functionality and architecture can be separated according to the number of terminal hydroxy groups on polar stationary phases in acetone water mobile phases containing 90–97% acetone. The best results were obtained on a HILIC column. Typical samples, which can be analyzed by this technique, are polyethylene glycols, their mono- and dialkyl ethers, macromonomers, the fatty esters of PEG, and ethoxylated glycerol.
- 8 July 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (4) , 1535-1545
Separation of all oligomers in polyethylene glycols and their monomethyl ethers by one-dimensional liquid chromatography
Different polymer homologous series having the same repeat unit, but different end groups, can be separated by one-dimensional LAC according to the number of repeat units and functionality, if a favorable combination of the interaction parameters of the repeat unit and the end groups can be found. As an example, polyethylene glycol (PEG) can be determined in PEG monomethyl ethers. The molar mass distribution of the minor component in such samples can be determined even at concentrations of a few percent. LAC of PEG-MME 350 containing different amounts of PEG 600 and the pure samples on the Synergi MAX RP column in 12.15 wt-% acetone at 25°C. Detection: RI
- 8 July 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (4) , 1535-1545
Separation of all oligomers in polyethylene glycols and their monomethyl ethers by one-dimensional liquid chromatography
Different polymer homologous series having the same repeat unit, but different end groups, can be separated by one-dimensional LAC according to the number of repeat units and functionality, if a favorable combination of the interaction parameters of the repeat unit and the end groups can be found. As an example, polyethylene glycol (PEG) can be determined in PEG monomethyl ethers. The molar mass distribution of the minor component in such samples can be determined even at concentrations of a few percent. LAC of PEG-MME 350 containing different amounts of PEG 600 and the pure samples on the Synergi MAX RP column in 12.15 wt-% acetone at 25°C. Detection: RI
- 8 July 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (14) , 2052-2059
Liquid chromatography at critical conditions in ternary mobile phases: Gradient elution along the critical line
In ternary mobile phases consisting of acetone, methanol, and water, the retention of PEG on reversed‐phase columns is independent on molar mass at certain compositions of the mobile phase. Along this critical adsorption line, the retention of polypropylene glycol varies quite strongly, which can be utilized in the separation of block copolymers. Gradient elution along the critical line allows a baseline separation of all oligomers in polypropylene glycol up to approximately 25 propylene oxide units. The same resolution can be achieved in the separation of ethylene oxide‐propylene oxide block copolymers, regardless of the length of the ethylene oxide block.
- 8 July 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (14) , 2052-2059
Liquid chromatography at critical conditions in ternary mobile phases: Gradient elution along the critical line
In ternary mobile phases consisting of acetone, methanol, and water, the retention of PEG on reversed‐phase columns is independent on molar mass at certain compositions of the mobile phase. Along this critical adsorption line, the retention of polypropylene glycol varies quite strongly, which can be utilized in the separation of block copolymers. Gradient elution along the critical line allows a baseline separation of all oligomers in polypropylene glycol up to approximately 25 propylene oxide units. The same resolution can be achieved in the separation of ethylene oxide‐propylene oxide block copolymers, regardless of the length of the ethylene oxide block.
- 9 June 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (4) , 1523-1534
Quantification in the analysis of polyethylene glycols and their monomethyl ethers by liquid adsorption chromatography with different detectors
It is shown that the molar mass distribution of polyethylene glycols (PEGs) and their monomethyl ethers can be determined by liquid adsorption chromatography (LAC) on reversed phases using isocratic or gradient elution. In gradient LAC, the evaporative light scattering detector (ELSD) has to be used, which is, however, problematic with respect to quantification. The response factors of the individual oligomers depend strongly on the operating conditions, molar mass, and sample size. These problems do not arise with density and refractive index detection, which can, however, only be applied with isocratic elution. A comparison of the results obtained with these three detectors showed that calibration of the ELSD has to be performed very carefully. Molar mass distribution of PEG 600, as obtained by LAC with different detectors
- 9 June 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 399 (4) , 1523-1534
Quantification in the analysis of polyethylene glycols and their monomethyl ethers by liquid adsorption chromatography with different detectors
It is shown that the molar mass distribution of polyethylene glycols (PEGs) and their monomethyl ethers can be determined by liquid adsorption chromatography (LAC) on reversed phases using isocratic or gradient elution. In gradient LAC, the evaporative light scattering detector (ELSD) has to be used, which is, however, problematic with respect to quantification. The response factors of the individual oligomers depend strongly on the operating conditions, molar mass, and sample size. These problems do not arise with density and refractive index detection, which can, however, only be applied with isocratic elution. A comparison of the results obtained with these three detectors showed that calibration of the ELSD has to be performed very carefully. Molar mass distribution of PEG 600, as obtained by LAC with different detectors
- 16 April 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (8) , 1052-1057
Retention of functional polymers in liquid adsorption chromatography: Effect of the end groups in PEGs and their methyl ethers in different mobile phases
It is shown that the end group parameter, which describes the influence of the end group on retention, can be determined in RP chromatography from two chromatograms of a nonfunctional and a monofunctional sample, if a sufficient number of peaks with the same number of repeat units in each sample can be reasonably resolved and identified. The same procedure can also be applied for pairs of di‐ and monofunctional polymers. End group parameters have been determined in three different mobile phases: acetonitrile–water, acetone–water and methanol–water of different compositions. The temperature dependence of the interaction parameter of the repeat unit and the end group parameter has been found to be different, which allows a fine‐tuning of retention.
- 16 April 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (8) , 1052-1057
Retention of functional polymers in liquid adsorption chromatography: Effect of the end groups in PEGs and their methyl ethers in different mobile phases
It is shown that the end group parameter, which describes the influence of the end group on retention, can be determined in RP chromatography from two chromatograms of a nonfunctional and a monofunctional sample, if a sufficient number of peaks with the same number of repeat units in each sample can be reasonably resolved and identified. The same procedure can also be applied for pairs of di‐ and monofunctional polymers. End group parameters have been determined in three different mobile phases: acetonitrile–water, acetone–water and methanol–water of different compositions. The temperature dependence of the interaction parameter of the repeat unit and the end group parameter has been found to be different, which allows a fine‐tuning of retention.
- 16 April 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (8) , 1064-1071
Adsorption interaction parameter of polyethers in ternary mobile phases: The critical adsorption line
It is shown that in LC of polymers, the interaction parameter in ternary mobile phases can be described by a plane, which is determined by the dependencies in binary mobile phases. Instead of a critical adsorption point, critical conditions are observed along a straight line of composition between the two critical points in binary mobile phases. Consequently, a separation of block copolymers under critical conditions for one block by an adsorption mechanism for the other block can be achieved in ternary mobile phases of different compositions, which allows an adjustment of the retention of the adsorbing block.
- 16 April 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (8) , 1064-1071
Adsorption interaction parameter of polyethers in ternary mobile phases: The critical adsorption line
It is shown that in LC of polymers, the interaction parameter in ternary mobile phases can be described by a plane, which is determined by the dependencies in binary mobile phases. Instead of a critical adsorption point, critical conditions are observed along a straight line of composition between the two critical points in binary mobile phases. Consequently, a separation of block copolymers under critical conditions for one block by an adsorption mechanism for the other block can be achieved in ternary mobile phases of different compositions, which allows an adjustment of the retention of the adsorbing block.
- 5 March 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (4-5) , 464-474
Determination of thermodynamic parameters in reversed phase chromatography for polyethylene glycols and their methyl ethers in different mobile phases
The thermodynamic parameters (entropy and enthalpy change) and their increment per repeat unit have been determined in RP chromatography of PEG and its mono‐ and dimethyl ethers in different mobile phases. The different approaches for their determination and the problems related to the characteristic volumes (void volume, interstitial volume, pore volume) of the column are discussed. Very different dependences or the thermodynamic parameters were observed in aqueous mobile phases containing ACN, acetone, or methanol as organic modifier. In the first two mobile phases a linear dependence on the number of repeat units n is found, and the additional entropy and enthalpy changes per repeat unit are positive. In methanol–water, the enthalpy change is negative with a non‐linear dependence on n, and the entropy change is independent on n and close to zero. The contribution of the end groups is almost the same in the first two mobile phases, but much smaller in methanol–water.
- 5 March 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (4-5) , 464-474
Determination of thermodynamic parameters in reversed phase chromatography for polyethylene glycols and their methyl ethers in different mobile phases
The thermodynamic parameters (entropy and enthalpy change) and their increment per repeat unit have been determined in RP chromatography of PEG and its mono‐ and dimethyl ethers in different mobile phases. The different approaches for their determination and the problems related to the characteristic volumes (void volume, interstitial volume, pore volume) of the column are discussed. Very different dependences or the thermodynamic parameters were observed in aqueous mobile phases containing ACN, acetone, or methanol as organic modifier. In the first two mobile phases a linear dependence on the number of repeat units n is found, and the additional entropy and enthalpy changes per repeat unit are positive. In methanol–water, the enthalpy change is negative with a non‐linear dependence on n, and the entropy change is independent on n and close to zero. The contribution of the end groups is almost the same in the first two mobile phases, but much smaller in methanol–water.
- 27 August 2009
- Published by Wiley in Journal of Separation Science
- Vol. 32 (17) , 2857-2863
A data base for polymer chromatography: Temperature dependence of interaction parameters in liquid adsorption chromatography
The temperature dependence of retention behaviour of polyethylene glycol (PEG) and its mono‐ and dimethyl ethers was studied on various RP columns in different mobile phases. The accessible volumes and the interaction parameters were determined from slope and intercept in a plot of the elution volumes of the oligomers of a polymer homologous series as a function of the difference of the elution volumes of consecutive oligomers. A quite different dependence of the interaction parameters was observed in the different mobile phases. While in methanol–water the interaction parameter decreases with increasing temperature, the opposite effect is observed in acetonitrile (ACN)–water. In acetone–water, the temperature dependence is almost negligible.
- 27 August 2009
- Published by Wiley in Journal of Separation Science
- Vol. 32 (17) , 2857-2863
A data base for polymer chromatography: Temperature dependence of interaction parameters in liquid adsorption chromatography
The temperature dependence of retention behaviour of polyethylene glycol (PEG) and its mono‐ and dimethyl ethers was studied on various RP columns in different mobile phases. The accessible volumes and the interaction parameters were determined from slope and intercept in a plot of the elution volumes of the oligomers of a polymer homologous series as a function of the difference of the elution volumes of consecutive oligomers. A quite different dependence of the interaction parameters was observed in the different mobile phases. While in methanol–water the interaction parameter decreases with increasing temperature, the opposite effect is observed in acetonitrile (ACN)–water. In acetone–water, the temperature dependence is almost negligible.