HYHiroyuki Yoshida

Hiroyuki Yoshida

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hiroyuki Yoshida has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Computer-Aided diagnosis for CT colonography

    by Hiroyuki Yoshida, Abraham H. Dachman


  • CAD techniques, challenges, andcontroversies in computed tomographic colonography

    by H. Yoshida, A. H. Dachman

    Computer-aided diagnosis (CAD) for computed tomographic colonography (CTC) automatically detects the locations of suspicious polyps and masses on CTC and provides radiologists with a second opinion. CAD has the potential to increase radiologists’ diagnostic performance in the detection of polyps and masses and to decrease variability of the diagnostic accuracy among readers without significantly increasing the reading time. Technical developments have advanced CAD substantially during the past several years, and a fundamental scheme for the detection of polyps has been established. The most recent CAD systems based on this scheme produce a clinically acceptable high sensitivity and a low false-positive rate. However, CAD for CTC is still under active development, and the technology needs to be improved further. This report describes the expected benefits, the current fundamental scheme, the key techniques used for detection of polyps and masses on CTC, the current detection performance, as well as the pitfalls, challenges, controversies, and the future of CAD.


  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images

    by Hiroyuki Yoshida, David D Casalino, Bilgin Keserci, Abdulhakim Coskun, Omer Ozturk, Ahmet Savranlar

    The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesions were decomposed into subimages by wavelet packets. Multiscale texture features that quantify homogeneity of the echogenicity were calculated from these subimages and were combined by an artificial neural network (ANN). A subset of the multiscale features was selected that yielded the highest performance in the classification of lesions measured by the area under the receiver operating characteristic curve (Az). In an analysis of 193 ROIs consisting of 50 hemangiomas, 87 hepatocellular carcinomas and 56 metastases, the multiscale features yielded a high Az value of 0.92 in distinguishing benign from malignant lesions, 0.93 in distinguishing hemangiomas from HCCs and 0.94 in distinguishing hemangiomas from metastases. Our new multiscale texture analysis method can effectively differentiate malignant from benign lesions, and thus has the potential to increase the accuracy of diagnosis of focal liver lesions in ultrasound images.


  • Multiscale edge-guided wavelet snake model for delineation of pulmonary nodules in chest radiographs

    by Hiroyuki Yoshida

    A novel approach based on a multiscale edge-guided wavelet snake model is developed for deliniation of pulmonary nodules in digital chest radiographs. The approach is applied to the differentiation of nodules and false positives reported by our computer-aided diagnosis (CAD) scheme for detection of nodules. The wavelet snake is a deformable contour that is designed to identify the boundary of a round object. The shape of the snake is determined by a set of wavelet coefficients in a certain range of scales. Portions of the boundary of a nodule are first extracted by multiscale edge representation. Then the multiscale edges are fitted by deformation of the shape of the snake through a change in the wavelet coefficients by use of a gradient descent algorithm. The degree of overlap between the fitted snake and the multiscale edges is calculated as a measure for classification of nodules and false detections. A total of 242 regions of interest, consisting of 90 nodules and 152 false positives, reported by our existing CAD scheme are used for evaluation of our method by means of receiver operating characteristic (ROC) analysis. The false positives are difficult to distinguish from nodules, because they cannot be removed, even though various methods for false-positive elimination processes are employed in our CAD scheme. Our method based on the multiscale edge-guided snake model yields an area under the ROC curve of 0.74, which can eliminate 15% of false positives with the sacrifice of only one nodule. The result indicates that our method appears to be effective in the classification of nodules and false positives, even when difficult false positives are included. © 2003 SPIE and IS&T.


  • Computer-aided Diagnosis Scheme for Detection of Polyps at CT Colonography

    by Hiroyuki Yoshida, Janne Näppi, Peter MacEneaney, David T. Rubin, Abraham H. Dachman

    Colon cancer is one of the leading causes of cancer deaths in the United States. However, most colon cancers can be prevented if precursor colonic polyps are detected and removed. An advanced computer-aided diagnosis (CAD) scheme was developed for the automated detection of polyps at computed tomographic (CT) colonography. A region encompassing the colonic wall is extracted from an isotropic volume data set obtained by interpolating CT colonographic scans along the axial direction. Polyp candidates are detected with computation of three-dimensional (3D) geometric features that characterize polyps, followed by extraction of polyps with hysteresis thresholding and fuzzy clustering using these geometric features. The number of false-positive findings is reduced by extracting 3D texture features from polyp candidates and applying quadratic discriminant analysis to the candidates. This CAD scheme was applied in 71 patients who underwent CT colonography, 14 of whom had colonoscopically confirmed polyps (n = 21)...


  • Computerized Detection of Colonic Polyps at CT Colonography on the Basis of Volumetric Features: Pilot Study

    by Hiroyuki Yoshida, Yoshitaka Masutani, Peter MacEneaney, David T. Rubin, Abraham H. Dachman

    PURPOSE: To develop a computer-aided diagnosis (CAD) scheme for automated detection of colonic polyps on the basis of volumetric features and to assess its accuracy on the basis of colonoscopy, the standard. MATERIALS AND METHODS: Computed tomographic (CT) colonography was performed in patients with use of standard bowel cleansing, air insufflation, and helical scanning in supine and prone positions. The colon was extracted from volumetric data sets generated from transverse CT sections. Volumetric features characterizing polyps were computed at each point in the extracted colon. Polyps were detected by means of hysteresis thresholding and fuzzy clustering followed by a rule-based test on the basis of feature values. Locations of the detected polyps were compared with those detected at conventional colonoscopy. RESULTS: Forty-one cases were analyzed: nine cases with polyps and 32 without polyps. Each case with polyps had one polyp of clinically important size (six were 5–9 mm; three, 10 mm). Thus, there w...


  • Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps

    by H. Yoshida, J. Nappi

    We have developed a three-dimensional (3-D) computer-aided diagnosis scheme for automated detection of colonic polyps in computed tomography (CT) colonographic data sets, and assessed its performance based on colonoscopy as the gold standard. In this scheme, a thick region encompassing the entire colonic wall is extracted from an isotropic volume reconstructed from the CT images in CT colonography. Polyp candidates are detected by first computing of 3-D geometric features that characterize polyps, folds, and colonic walls at each voxel in the extracted colon, and then segmenting of connected components corresponding to suspicious regions by hysteresis thresholding based on these geometric features. We apply fuzzy clustering to these connected components to obtain the polyp candidates. False-positive (FP) detections are then reduced by computation of several 3-D volumetric features characterizing the internal structures of the polyp candidates, followed by the application of discriminant analysis to the feature space generated by these volumetric features. The locations of the polyps detected by our computerized method were compared to the gold standard of conventional colonoscopy. The performance was evaluated based on 43 clinical cases, including 12 polyps determined by colonoscopy. Our computerized scheme was shown to have the potential to detect polyps in CT colonography with a clinically acceptable high sensitivity and a low FP rate.