Kenji Sakurai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kenji Sakurai has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Masaaki Harada
National Research Institute for Metals, 1-2-1 Sengen, Tsukuba, Ibaraki 305, Japan
2 shared publicationsShouji Uehara
Kohzu Seiki Co. Ltd, 2-27-37 Mishuku, Setagaya, Tokyo 154, Japan
1 shared publicationShunji Goto
JASRI, SPring-8, Kamigori, Ako-gun, Hyogo 678-12, Japan
1 shared publicationXiaomei Guo
National Research Institute for Metals, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047, Japan
1 shared publication
Latest Publications
- 4 January 1999
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 54 (1) , 29-39
K-line X-ray fluorescence analysis of high-Z elements
- 4 January 1999
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 54 (1) , 29-39
K-line X-ray fluorescence analysis of high-Z elements
- 4 January 1999
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 54 (1) , 99-107
Recent performance of laboratory-scale X-ray absorption fine structure instruments
- 4 January 1999
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 54 (1) , 99-107
Recent performance of laboratory-scale X-ray absorption fine structure instruments
- 1 May 1998
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 5 (3) , 554-556
A grazing-incidence reflectometer for BL-39XU at SPring-8
A new grazing-incidence reflectometer has been designed for the X-ray undulator beamline BL-39XU at SPring-8. It will be used for analytical applications, especially ultra-trace-level determination by total reflection X-ray fluorescence (TXRF), nanometer-scale surface topography by specular/non-specular X-ray reflection, and thin-film interface studies by combined measurements of X-ray fluorescence and X-ray reflection. The requirements for the instrument and the solutions in the present design are discussed. A prototype has been developed to test the feasibility of the design. It has been confirmed that the measurements planned at the beamline are achievable with this reflectometer.
- 1 May 1998
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 5 (3) , 554-556
A grazing-incidence reflectometer for BL-39XU at SPring-8
A new grazing-incidence reflectometer has been designed for the X-ray undulator beamline BL-39XU at SPring-8. It will be used for analytical applications, especially ultra-trace-level determination by total reflection X-ray fluorescence (TXRF), nanometer-scale surface topography by specular/non-specular X-ray reflection, and thin-film interface studies by combined measurements of X-ray fluorescence and X-ray reflection. The requirements for the instrument and the solutions in the present design are discussed. A prototype has been developed to test the feasibility of the design. It has been confirmed that the measurements planned at the beamline are achievable with this reflectometer.
- 1 February 1996
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 67 (2) , 615-616
Narrow pulse shaping for high-counting-rate x-ray measurements
- 1 February 1996
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 67 (2) , 615-616
Narrow pulse shaping for high-counting-rate x-ray measurements