Giuseppe Pezzotti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Giuseppe Pezzotti has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Wenliang Zhu
Kyoto Institute of Technology, Ceramic Physics Laboratory, Research Institute of Nanoscience, Sakyo-ku, Matsugasaki, Kyoto 606-8585, Japan
3 shared publicationsS. M. F. Asmus
Ceramic Physics Laboratory & Research Institute for Nanoscience Kyoto Institute of Technology Sakyo-ku, Matsugasaki 606-8585 Kyoto, Japan
2 shared publicationsS. Sakakura
Ceramic Physics Laboratory & Research Institute for Nanoscience Kyoto Institute of Technology Sakyo-ku, Matsugasaki 606-8585 Kyoto, Japan
2 shared publicationsW. H. Müller
Technische Universit?t Berlin, Institut f?r Mechanik, Lehrstuhl f?r Kontinuumsmechanik und Materialtheorie, Einsteinufer 5, 10586 Berlin, Germany
2 shared publicationsKengo Yamamoto
Tokyo Medical University, Department of Orthopaedic Surgery, Shinjuku-ku, 6-7-1 Nishishinjuku, Tokyo 160-0023, Japan
1 shared publication- Keshu Wan
Southeast University
1 shared publication
Latest Publications
- Open Access
- 1 January 2007
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (1) , 014011-014011-14
Confocal Raman spectroscopic analysis of cross-linked ultra-high molecular weight polyethylene for application in artificial hip joints
Confocal spectroscopic techniques are applied to selected Raman bands to study the microscopic features of acetabular cups made of ultra-high molecular weight polyethylene (UHMWPE) before and after implantation in vivo. The micrometric lateral resolution of a laser beam focused on the polymeric surface (or subsurface) enables a highly resolved visualization of 2-D conformational population patterns, including crystalline, amorphous, orthorhombic phase fractions, and oxidation index. An optimized confocal probe configuration, aided by a computational deconvolution of the optical probe, allows minimization of the probe size along the in-depth direction and a nondestructive evaluation of microstructural properties along the material subsurface. Computational deconvolution is also attempted, based on an experimental assessment of the probe response function of the polyethylene Raman spectrum, according to a defocusing technique. A statistical set of high-resolution microstructural data are collected on a fully 3-D level on -ray irradiated UHMWPE acetabular cups both as-received from the maker and after retrieval from a human body. Microstructural properties reveal significant gradients along the immediate material subsurface and distinct differences are found due to the loading history in vivo, which cannot be revealed by conventional optical spectroscopy. The applicability of the confocal spectroscopic technique is valid beyond the particular retrieval cases examined in this study, and can be easily extended to evaluate in-vitro tested components or to quality control of new polyethylene brands. Confocal Raman spectroscopy may also contribute to rationalize the complex effects of -ray irradiation on the surface of medical grade UHMWPE for total joint replacement and, ultimately, to predict their actual lifetime in vivo.- 1 January 2007
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (1) , 014011-014011-14
Open AccessConfocal Raman spectroscopic analysis of cross-linked ultra-high molecular weight polyethylene for application in artificial hip joints
Confocal spectroscopic techniques are applied to selected Raman bands to study the microscopic features of acetabular cups made of ultra-high molecular weight polyethylene (UHMWPE) before and after implantation in vivo. The micrometric lateral resolution of a laser beam focused on the polymeric surface (or subsurface) enables a highly resolved visualization of 2-D conformational population patterns, including crystalline, amorphous, orthorhombic phase fractions, and oxidation index. An optimized confocal probe configuration, aided by a computational deconvolution of the optical probe, allows minimization of the probe size along the in-depth direction and a nondestructive evaluation of microstructural properties along the material subsurface. Computational deconvolution is also attempted, based on an experimental assessment of the probe response function of the polyethylene Raman spectrum, according to a defocusing technique. A statistical set of high-resolution microstructural data are collected on a fully 3-D level on -ray irradiated UHMWPE acetabular cups both as-received from the maker and after retrieval from a human body. Microstructural properties reveal significant gradients along the immediate material subsurface and distinct differences are found due to the loading history in vivo, which cannot be revealed by conventional optical spectroscopy. The applicability of the confocal spectroscopic technique is valid beyond the particular retrieval cases examined in this study, and can be easily extended to evaluate in-vitro tested components or to quality control of new polyethylene brands. Confocal Raman spectroscopy may also contribute to rationalize the complex effects of -ray irradiation on the surface of medical grade UHMWPE for total joint replacement and, ultimately, to predict their actual lifetime in vivo. - 20 December 2005
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 5 (1) , 349-350
Micromechanics of fracture in Partially Stabilized Zirconia (PSZ) studiedby in‐situ Raman spectroscopy
- 20 December 2005
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 5 (1) , 349-350
Micromechanics of fracture in Partially Stabilized Zirconia (PSZ) studiedby in‐situ Raman spectroscopy
- 15 December 2005
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 17 (1) , 181-190
Methods of piezo-spectroscopic calibration of thin-film materials: I. Ball-on-ring biaxial flexure
A ball-on-ring flexure jig has been developed for applying a controlled biaxial stress to thin-film materials and its reliability is validated by measuring the biaxial piezo-spectroscopic coefficients (namely the wavelength shift rate upon stress) of selected bands from the fluorescence or Raman spectrum of two technically important materials, silicon and sapphire films. Due to the small thickness of the investigated samples, measurement conditions had to be adjusted according to the transparency characteristics of the material for laser probe to gain meaningful stress information upon loading the plate. Two different procedures have been developed: (i) a surface scan along an arbitrary diameter of the flexure plate was found to be appropriate only for opaque materials, in which the penetration depth of the laser probe was negligible in comparison with the stress gradient developed along the sample thickness; and (ii) a 'through-focus' scan along the plate thickness (coupled with an analytical deconvolution of the optical probe) at a selected point of the sample was found to be the most reliable method for assessing highly transparent materials with an acceptable calculation time (i.e. by ignoring the stress distribution and probe function in the x–y plane). The workable defocus distance in the 'through-focus' scan method, which is available for very thin films and large probe sizes, was discussed accordingly. These calibration procedures may be useful in piezo-spectroscopic stress assessments of semiconductor materials for which bulk specimens may not be available.
- 15 December 2005
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 17 (1) , 181-190
Methods of piezo-spectroscopic calibration of thin-film materials: I. Ball-on-ring biaxial flexure
A ball-on-ring flexure jig has been developed for applying a controlled biaxial stress to thin-film materials and its reliability is validated by measuring the biaxial piezo-spectroscopic coefficients (namely the wavelength shift rate upon stress) of selected bands from the fluorescence or Raman spectrum of two technically important materials, silicon and sapphire films. Due to the small thickness of the investigated samples, measurement conditions had to be adjusted according to the transparency characteristics of the material for laser probe to gain meaningful stress information upon loading the plate. Two different procedures have been developed: (i) a surface scan along an arbitrary diameter of the flexure plate was found to be appropriate only for opaque materials, in which the penetration depth of the laser probe was negligible in comparison with the stress gradient developed along the sample thickness; and (ii) a 'through-focus' scan along the plate thickness (coupled with an analytical deconvolution of the optical probe) at a selected point of the sample was found to be the most reliable method for assessing highly transparent materials with an acceptable calculation time (i.e. by ignoring the stress distribution and probe function in the x–y plane). The workable defocus distance in the 'through-focus' scan method, which is available for very thin films and large probe sizes, was discussed accordingly. These calibration procedures may be useful in piezo-spectroscopic stress assessments of semiconductor materials for which bulk specimens may not be available.
- 1 August 2005
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 59 (8) , 1042-1048
Spatially Resolved Stress Analysis in Al 2 O 3 /3Y-TZP Multilayered Composite Using Confocal Fluorescence Spectroscopy
Fluorescence piezo-spectroscopy (PS) was applied to evaluate the residual stress fields stored in a multilayered Al 2 O 3 /3Y-TZP (3 mol % Y 2 O 3 -stabilized ZrO 2 ) composite using the chromophoric fluorescence spectra of Al 2 O 3 . The PS results were compared with a theoretical stress distribution in the laminate, calculated according to a repeating unit cell model. However, in practical fluorescence spectroscopy, each measurement point corresponded to a finite volume of material, within which the scattered light experienced fluorescence wavelengths characteristic of the local (weight-average) stress fields. Because of the finite volume of material probed in PS measurements, a comparison between the experimental and calculated values requires that the calculated stresses be convoluted according to the depth-response function of the probe. A pinhole aperture incorporated in the Raman microprobe was used to control the collection probe depth and to modulate the portion of the whole fluorescence emission reaching the detector. According to calibrations of the probe depth and probe response function, probe-convoluted stresses were obtained and a spatially resolved mapping of residual stresses could be obtained.
- 1 August 2005
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 59 (8) , 1042-1048
Spatially Resolved Stress Analysis in Al 2 O 3 /3Y-TZP Multilayered Composite Using Confocal Fluorescence Spectroscopy
Fluorescence piezo-spectroscopy (PS) was applied to evaluate the residual stress fields stored in a multilayered Al 2 O 3 /3Y-TZP (3 mol % Y 2 O 3 -stabilized ZrO 2 ) composite using the chromophoric fluorescence spectra of Al 2 O 3 . The PS results were compared with a theoretical stress distribution in the laminate, calculated according to a repeating unit cell model. However, in practical fluorescence spectroscopy, each measurement point corresponded to a finite volume of material, within which the scattered light experienced fluorescence wavelengths characteristic of the local (weight-average) stress fields. Because of the finite volume of material probed in PS measurements, a comparison between the experimental and calculated values requires that the calculated stresses be convoluted according to the depth-response function of the probe. A pinhole aperture incorporated in the Raman microprobe was used to control the collection probe depth and to modulate the portion of the whole fluorescence emission reaching the detector. According to calibrations of the probe depth and probe response function, probe-convoluted stresses were obtained and a spatially resolved mapping of residual stresses could be obtained.
- Open Access
- 1 December 2004
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 4 (1) , 726-727
Mikrobruchmechanik in einem Keramik-Metall-Verbundwerkstoff mit Hilfe der in-situ Fluoreszenzspektroskopie
- 1 December 2004
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 4 (1) , 726-727
Open AccessMikrobruchmechanik in einem Keramik-Metall-Verbundwerkstoff mit Hilfe der in-situ Fluoreszenzspektroskopie
- 1 October 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (3) , 577-590
Raman piezo-spectroscopic analysis of natural and synthetic biomaterials
Raman piezo-spectroscopy of bone, teeth, and artificial joints is reviewed with emphasis placed on confocal microprobe techniques. Characteristic spectra are presented and quantitative assessments of their phase structure and stress dependence are shown. Vibrational spectroscopy is used here to study the microscopic stress response of cortical bone to external stress (with or without internal damages), to define microscopic stresses across the dentine–enamel junction under increasing external compressive load, and to characterize interactions between prosthetic implants and biological environment. Confocal spectroscopy allows acquisition of spatially resolved spectra and stress imaging with high spatial resolution.
- 1 October 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (3) , 577-590
Raman piezo-spectroscopic analysis of natural and synthetic biomaterials
Raman piezo-spectroscopy of bone, teeth, and artificial joints is reviewed with emphasis placed on confocal microprobe techniques. Characteristic spectra are presented and quantitative assessments of their phase structure and stress dependence are shown. Vibrational spectroscopy is used here to study the microscopic stress response of cortical bone to external stress (with or without internal damages), to define microscopic stresses across the dentine–enamel junction under increasing external compressive load, and to characterize interactions between prosthetic implants and biological environment. Confocal spectroscopy allows acquisition of spatially resolved spectra and stress imaging with high spatial resolution.
- 1 December 2003
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 37 (23) , 2117-2129
Hydroxyapatite Toughened by Silver Inclusions
Three kinds of processing procedure, including conventional sintering, hot-isostatic pressing, and their combination, were explored to prepare hydroxyapatite-silver composites with high density and improved ceramic-metal interface properties. Optimizing the densification procedure, which allowed the desired fraction of Ag to remain within the apatite matrix after densification, has solved a problem related to the low wettability of Ag on hydroxyapatite. The major outcome of this study is that hot-isostatic pressing enables to reinforce the interface between hydroxyapatite and silver, thus improving the structural consistency of the prepared composite. Results are supported by investigations on microscopic fracture mechanisms. It is shown, that a toughening effect arose from the microscopic crack-bridging mechanism operated by the elasto-plastic stretching of unbroken Ag ligaments along the crack wake. A Raman piezo-spectroscopic technique enabled the in situ quantitative assessment of this bridging toughening mechanism.
- 1 December 2003
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 37 (23) , 2117-2129
Hydroxyapatite Toughened by Silver Inclusions
Three kinds of processing procedure, including conventional sintering, hot-isostatic pressing, and their combination, were explored to prepare hydroxyapatite-silver composites with high density and improved ceramic-metal interface properties. Optimizing the densification procedure, which allowed the desired fraction of Ag to remain within the apatite matrix after densification, has solved a problem related to the low wettability of Ag on hydroxyapatite. The major outcome of this study is that hot-isostatic pressing enables to reinforce the interface between hydroxyapatite and silver, thus improving the structural consistency of the prepared composite. Results are supported by investigations on microscopic fracture mechanisms. It is shown, that a toughening effect arose from the microscopic crack-bridging mechanism operated by the elasto-plastic stretching of unbroken Ag ligaments along the crack wake. A Raman piezo-spectroscopic technique enabled the in situ quantitative assessment of this bridging toughening mechanism.
- 12 March 2003
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 65A (2) , 229-236
Study of the toughening mechanisms in bone and biomimetic hydroxyapatite materials using Raman microprobe spectroscopy
A Raman microprobe spectroscopy characterization of microscopic fracture mechanisms is presented for a natural hydroxyapatite material (cortical bovine femur) and two synthetic hydroxyapatite‐based materials with biomimetic structures—a hydroxyapatite skeleton interpenetrated with a metallic (silver) or a polymeric (nylon‐6) phase. In both the natural and synthetic materials, a conspicuous amount of toughening arose from a microscopic crack‐bridging mechanism operated by elasto‐plastic stretching of unbroken second‐phase ligaments along the crack wake. This mechanism led to a rising R‐curve behavior. An additional micromechanism, responsible for stress relaxation at the crack tip, was recognized in the natural bone material and was partly mimicked in the hydroxyapatite/silver composite. This crack‐tip mechanism conspicuously enhanced the cortical bone material resistance to fracture initiation. A piezo‐spectroscopic technique, based on a microprobe measurement of 980 cm−1 Raman line of hydroxyapatite, enabled us to quantitatively assess in situ the microscopic stress fields developed during fracture both at the crack tip and along the crack wake. Using the Raman piezo‐spectroscopy technique, toughening mechanisms were assessed quantitatively and rationally related to the macroscopic fracture characteristics of hydroxyapatite‐based materials. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 229–236, 2003
- 12 March 2003
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 65A (2) , 229-236
Study of the toughening mechanisms in bone and biomimetic hydroxyapatite materials using Raman microprobe spectroscopy
A Raman microprobe spectroscopy characterization of microscopic fracture mechanisms is presented for a natural hydroxyapatite material (cortical bovine femur) and two synthetic hydroxyapatite‐based materials with biomimetic structures—a hydroxyapatite skeleton interpenetrated with a metallic (silver) or a polymeric (nylon‐6) phase. In both the natural and synthetic materials, a conspicuous amount of toughening arose from a microscopic crack‐bridging mechanism operated by elasto‐plastic stretching of unbroken second‐phase ligaments along the crack wake. This mechanism led to a rising R‐curve behavior. An additional micromechanism, responsible for stress relaxation at the crack tip, was recognized in the natural bone material and was partly mimicked in the hydroxyapatite/silver composite. This crack‐tip mechanism conspicuously enhanced the cortical bone material resistance to fracture initiation. A piezo‐spectroscopic technique, based on a microprobe measurement of 980 cm−1 Raman line of hydroxyapatite, enabled us to quantitatively assess in situ the microscopic stress fields developed during fracture both at the crack tip and along the crack wake. Using the Raman piezo‐spectroscopy technique, toughening mechanisms were assessed quantitatively and rationally related to the macroscopic fracture characteristics of hydroxyapatite‐based materials. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 229–236, 2003
- 1 January 2003
- Published by Springer Nature in Journal of Materials Science Letters
- Vol. 22 (2) , 139-141
Fracture analysis of synthetic vs. natural hydroxyapatite composites by Raman microprobe spectroscopy
- 1 January 2003
- Published by Springer Nature in Journal of Materials Science Letters
- Vol. 22 (2) , 139-141
Fracture analysis of synthetic vs. natural hydroxyapatite composites by Raman microprobe spectroscopy
- 9 September 2002
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 33 (9) , 709-714
Micromechanical analysis of silicon nitride: a comparative study by fracture mechanics and Raman microprobe spectroscopy
Raman microprobe spectroscopy was used to characterize in situ microstress fields which develop during fracture of a toughened silicon nitride (Si3N4) polycrystal. Maps of microscopic stress were collected in the neighborhood of a propagating crack both at zero and at critical loading conditions. Micromechanics results by Raman spectroscopy were analyzed and compared with conventional fracture mechanics assessments, such as the evaluation of rising R‐curve behavior and crack opening displacement. Outcomes of these assessments illustrate that, despite the approximations involved in the piezo‐spectroscopic equations used for calculating the microstress field from a local Raman shift, Raman microprobe spectroscopy is a viable method for semi‐quantitative investigations of microfracture mechanisms in advanced ceramic materials. Copyright © 2002 John Wiley & Sons, Ltd.
- 9 September 2002
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 33 (9) , 709-714
Micromechanical analysis of silicon nitride: a comparative study by fracture mechanics and Raman microprobe spectroscopy
Raman microprobe spectroscopy was used to characterize in situ microstress fields which develop during fracture of a toughened silicon nitride (Si3N4) polycrystal. Maps of microscopic stress were collected in the neighborhood of a propagating crack both at zero and at critical loading conditions. Micromechanics results by Raman spectroscopy were analyzed and compared with conventional fracture mechanics assessments, such as the evaluation of rising R‐curve behavior and crack opening displacement. Outcomes of these assessments illustrate that, despite the approximations involved in the piezo‐spectroscopic equations used for calculating the microstress field from a local Raman shift, Raman microprobe spectroscopy is a viable method for semi‐quantitative investigations of microfracture mechanisms in advanced ceramic materials. Copyright © 2002 John Wiley & Sons, Ltd.