Jürgen Schmidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jürgen Schmidt has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
A. Beune
Technische Universiteit Eindhoven, Eindhoven, The Netherlands
2 shared publicationsRalf Diener
BASF AG, Inorganic Chemicals Europe, Ludwigshafen, Germany
2 shared publicationsW. Peschel
Valves and Fittings, Metal Processing, GTF/TB-G316, BASF SE, Ludwigshafen, Deutschland
2 shared publicationsAxel Schönbucher
Campus Essen, Universität Duisburg-Essen
1 shared publication- Dalibor Jerinić
Institute for Fluid Mechanics, Hamburg University of Technology, Eissendorfer Strasse 38, D-21073 Hamburg, Germany
1 shared publication Francis Stoessel
Swissi Process Safety GmbH, Schwarzwaldallee 215, CH‐4002 Basel, Switzerland
1 shared publication
Latest Publications
- 4 April 2012
- Published by Wiley
- p. 69-94
Sizing and Operation of High‐Pressure Safety Valves
- 7 July 2011
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 83 (8) , 1188-1199
Safety Devices and Disposal Systems for Multipurpose Plants. Part 2 – Disposal Systems
- 7 July 2011
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 83 (8) , 1188-1199
Safety Devices and Disposal Systems for Multipurpose Plants. Part 2 – Disposal Systems
- 7 July 2011
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 83 (8) , 1173-1187
Safety Devices and Disposal Systems for Multipurpose Plants. Part 1 – Safety Concept and Layer of Protection
- 7 July 2011
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 83 (8) , 1173-1187
Safety Devices and Disposal Systems for Multipurpose Plants. Part 1 – Safety Concept and Layer of Protection
- 29 April 2011
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 83 (6) , 796-812
Sizing of Safety Valves for Multi‐Purpose Plants according to ISO 4126‐10
Mehrzweckanlagen werden oft mit Sicherheitsventilen oder Berstscheiben abgesichert. Bei Produktwechseln muss regelmäßig überprüft werden, ob die Sicherheitseinrichtung für neue Produkte ausreichend groß bemessen ist. Die Auslegung kann jedoch sehr aufwendig sein. Deshalb werden energiespezifische Entlastungsflächen für ca. 60 typische Lösungsmittel bestimmt. Bei der Berechnung mit der HNE‐DS‐Methode, wie in ISO 4126‐10 empfohlen, wurde die Entlastung von Dampf/Flüssigkeits‐Gemischen berücksichtigt. Die Ergebnisse erlauben eine schnelle Bestimmung der erforderlichen Entlastungsfläche, wenn der Energieeintrag in den Reaktor bekannt ist. Es ergeben sich signifikant kleinere Entlastungsflächen als nach dem amerikanischem Regelwerk API 520.
- 29 April 2011
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 83 (6) , 796-812
Sizing of Safety Valves for Multi‐Purpose Plants according to ISO 4126‐10
Mehrzweckanlagen werden oft mit Sicherheitsventilen oder Berstscheiben abgesichert. Bei Produktwechseln muss regelmäßig überprüft werden, ob die Sicherheitseinrichtung für neue Produkte ausreichend groß bemessen ist. Die Auslegung kann jedoch sehr aufwendig sein. Deshalb werden energiespezifische Entlastungsflächen für ca. 60 typische Lösungsmittel bestimmt. Bei der Berechnung mit der HNE‐DS‐Methode, wie in ISO 4126‐10 empfohlen, wurde die Entlastung von Dampf/Flüssigkeits‐Gemischen berücksichtigt. Die Ergebnisse erlauben eine schnelle Bestimmung der erforderlichen Entlastungsfläche, wenn der Energieeintrag in den Reaktor bekannt ist. Es ergeben sich signifikant kleinere Entlastungsflächen als nach dem amerikanischem Regelwerk API 520.
- 1 May 2009
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 73 (2) , 105-117
Experimentelle und theoretische Untersuchungen zu Hochdruck-Sicherheitsventilen – Auslegung und Design unterstützt durch numerische Rechenmethoden (CFD)
- 1 May 2009
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 73 (2) , 105-117
Experimentelle und theoretische Untersuchungen zu Hochdruck-Sicherheitsventilen – Auslegung und Design unterstützt durch numerische Rechenmethoden (CFD)
- 21 March 2009
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 73 (1) , 1-2
Sicherheitstechnik im Wandel?
- 21 March 2009
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 73 (1) , 1-2
Sicherheitstechnik im Wandel?
- 29 January 2009
- Published by Wiley in Chemical Engineering & Technology
- Vol. 32 (2) , 252-262
Experimental and theoretical studies on high pressure safety valves: sizing and design supported by numerical calculations (CFD)
High‐pressure safety valves with set pressures of more than 200 bar are required in industry, e.g. for polyethylene and synthesis gas applications. They are presently sized according to ISO 4126‐1. Only equations for ideal gases are presented there, and there are no indications as to how the real gas factor and the adiabatic exponent for real gases are to be calculated. For this reason, an equation for the critical mass flow rate of a real gas through a nozzle was derived and compared with the model according to EN‐ISO 4126‐1 and with experimental data. It is recommended that the current ISO‐standard be supplemented by the nozzle flow model for real gases. The first numerical calculations (ANSYS‐CFX) show that the discharge coefficient for a high pressure safety valve measured at moderate pressures can be extrapolated to very high pressures if it is used in conjunction with the nozzle flow model for real gases. However, this numerical result must yet be validated for further valve types by experiment. For this purpose, BASF has set up a high pressure valve test facility in Ludwigshafen.
- 29 January 2009
- Published by Wiley in Chemical Engineering & Technology
- Vol. 32 (2) , 252-262
Experimental and theoretical studies on high pressure safety valves: sizing and design supported by numerical calculations (CFD)
High‐pressure safety valves with set pressures of more than 200 bar are required in industry, e.g. for polyethylene and synthesis gas applications. They are presently sized according to ISO 4126‐1. Only equations for ideal gases are presented there, and there are no indications as to how the real gas factor and the adiabatic exponent for real gases are to be calculated. For this reason, an equation for the critical mass flow rate of a real gas through a nozzle was derived and compared with the model according to EN‐ISO 4126‐1 and with experimental data. It is recommended that the current ISO‐standard be supplemented by the nozzle flow model for real gases. The first numerical calculations (ANSYS‐CFX) show that the discharge coefficient for a high pressure safety valve measured at moderate pressures can be extrapolated to very high pressures if it is used in conjunction with the nozzle flow model for real gases. However, this numerical result must yet be validated for further valve types by experiment. For this purpose, BASF has set up a high pressure valve test facility in Ludwigshafen.
- 28 January 2009
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 81 (1-2) , 79-95
Auslegung von Schutzeinrichtungen für wärmeübertragende Apparate
- 28 January 2009
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 81 (1-2) , 79-95
Auslegung von Schutzeinrichtungen für wärmeübertragende Apparate
- 1 March 2008
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 264 (1-2) , 253-258
Measurement of the triethylene glycol solubility in supercritical methane at pressures up to 9MPa
- 1 March 2008
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 264 (1-2) , 253-258
Measurement of the triethylene glycol solubility in supercritical methane at pressures up to 9MPa