NPNarinder S. Paul

Narinder S. Paul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Narinder S. Paul has a total of 91 co-authors. Here are the top co-authors by number of shared publications:

  • Ali Ursani

    University Health Network, Ontario, Canada

    4 shared publications
  • Hany Kashani

    All authors: Department of Medical Imaging, Toronto General Hospital, University Health Network, 585 University Ave, NCSB-1C562, Toronto, ON M5G 2N2, Canada

    3 shared publications
  • Heidi C. Roberts

    Joint Department of Medical Imaging, University Health Network/Mt. Sinai Hospital, Women's College Hospital, Toronto, Canada

    3 shared publications
  • Taebong Chung

    Department of Medical Imaging

    3 shared publications
  • Andre Pereira

    Department of Medical Imaging, University Health Network, Toronto, ON, Canada

    2 shared publications
  • Demetris Patsios

    Department of Medical Imaging, University Health Network, Toronto, ON, Canada

    2 shared publications

Latest Publications

  • Can MRT Practice Advance 3D Printing?

    by Vahid Anwari, Ashley Lai, Shailaja Sajja, Ali Ursani, Karina Rego, Narinder S. Paul


  • Safety and Efficacy of Modified Preoperative Lung Nodule Microcoil Localization Without Pleural Marking

    by Lan-Chau T. Md Kha, Kate Hanneman, Laura Donahoe, Taebong Chung, Andrew F. Md Pierre, Kazuhiro Yasufuku, Shafique Md Keshavjee, John R. Mayo, Narinder S. Paul, Elsie T. Nguyen

    Purpose: The purpose of this pilot study was to evaluate the safety and efficacy of preoperative computed tomography (CT)-guided percutaneous microcoil lung nodule localization without pleural marking compared with the established technique with pleural marking. Materials and Methods: Sixty-three consecutive patients (66.7% female, mean age 61.6±11.4 y) with 64 lung nodules resected between October 2008 and January 2014 were retrospectively evaluated. Of the nodules, 29.7% (n=19) had microcoil deployment with pleural marking (control group) and 70.3% (n=45) had microcoil deployment without pleural marking (pilot group). Clinical, pathologic, and imaging characteristics, radiation dose, CT procedure and operating room time, and complete resection and complication rates were compared between the pilot and control groups. Results: There was no significant difference in nodule size (P=0.552) or distance from the pleural surface (P=0.222) between the pilot and control groups. However, mean procedure duration (53.6±18.3 vs. 72.8±25.3 min, P=0.001) and total effective radiation dose (5.1±2.6 vs. 7.1±4.9 mSv, P=0.039) were significantly lower in the pilot group compared with the control group. CT procedure–related complications (P=0.483) [including pneumothoraces (P=0.769) and pulmonary hemorrhage (P=1.000)], operating room time (P=0.926), complete resection rates (P=0.520), intraoperative complications (P=0.549), and postoperative complications (P=1.000) were similar between the pilot and control groups. Conclusions: Preoperative CT-guided lung nodule microcoil localization performed without visceral pleural marking appears to decrease the CT procedure time and radiation dose while maintaining equivalent complete resection rates and procedural and surgical complications, when compared with microcoil localization performed with pleural marking.


  • Image Quality and Radiation Dose of Pulmonary CT Angiography Performed Using 100 and 120 kVp

    by Randy Fanous, Hany Kashani, Laura Jimenez, Grainne Murphy, Narinder S. Paul

    OBJECTIVE. The objective of our study was to compare image quality and radiation dose of pulmonary CT angiography (CTA) performed in the same patient cohort using tube potentials of 100 and 120 kVp. MATERIALS AND METHODS. The study group for this retrospective study was 32 patients (22 women, 10 men) with a mean age of 57 years (age range, 28-83 years; body weight < 100 kg). Patients underwent pulmonary CTA studies performed using 120 and 100 kVp while other scanning parameters were kept constant. Two observers measured image signal and image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and SNR dose and CNR dose. Two additional observers performed qualitative image quality analysis using a 5-point grading scale (5 = excellent). RESULTS. The reduction in tube potential caused image signal to increase by 29% (p < 0.0001), image noise to increase by 68% (p < 0.0001), CNR dose to decrease by 0.8% (p = 0.91) and SNR to decrease by 24% (p = 0.0002) and CNR by 20% (p = 0.0019). Radiation...


  • The Influence of Chest Wall Tissue Composition in Determining Image Noise During Cardiac CT

    by Narinder S. Paul, Hany Kashani, Devang Odedra, Ali Ursani, Chris Ray, Patrik Rogalla

    OBJECTIVE. The purpose of this article is to determine the influence of chest wall composition on image quality in cardiac CT. MATERIALS AND METHODS. A retrospective study of 100 consecutive patients referred for CT coronary artery calcium assessment was performed. Image noise (Hounsfield units) was measured by prescribing a region of interest in the descending thoracic aorta. Image noise was correlated with conventional patient biometric parameters, including body weight, body mass index (BMI), and anteroposterior and lateral thoracic diameters, and with novel patient biometric parameters, including total chest wall soft tissue, chest wall fat, and chest wall muscle and bone. The linear correlation coefficient was used to indicate the strength of the association. RESULTS. A strong correlation was noted between BMI and image noise in men (r = 0.66), but the strongest relationships were observed in larger women (BMI ≥ 25), who had more chest wall fat than muscle and very strong correlations between image n...


  • Radiation dose threshold for coronary artery calcium score with MDCT: How low can you go?

    by Tom D. Newton, Hatem Mehrez, Kelly Wong, Ravi Menezes, Bernd J. Wintersperger, Andrew Crean, Elsie Nguyen, Narinder Paul

    Objectives To evaluate the lowest radiation exposure threshold at which coronary calcium scoring (CCS) remains accurate. Methods A prospective study of 43 consecutive eligible patients referred for CCS underwent imaging in accordance with the manufacturer’s recommended protocol. Dedicated software was used to generate 8 series of images simulating tube currents ranging from 20 to 300 mA. These images were randomised and read in blinded fashion to determine the lowest tube current at which the CCS remained accurate. The minimum mA was correlated with 6 different patients’ biometric parameters: bodyweight, body mass index, AP and lateral thoracic diameters, average thoracic diameter and the scout attenuation coefficient (SAC). The 95% confidence interval for each parameter was used to calculate tube current threshold levels and hence stratified CCS protocols were derived. Results Spearman’s correlation coefficients of the minimum tube current for the 6 parameters were: 0.66, 0.63, 0.65, 0.74, 0.77 and 0.86 respectively (p < 0.001). SAC offered the largest potential reduction in mean effective dose from 1.86 mSv to 0.88 mSv. Conclusion CCS with at least 50% reduction in radiation exposure and below 1 mSv is feasible if CT scout projections are utilised effectively.


  • Direct Quantification of Breast Dose During Coronary CT Angiography and Evaluation of Dose Reduction Strategies

    by Sobhi Abadi, Hatem Mehrez, Ali Ursani, Mark Parker, Narinder Paul

    OBJECTIVE. The purpose of this study was to quantify the absorbed radiation dose received by the adult female breast during coronary CT angiography (CTA) and to evaluate the effectiveness of various dose reduction strategies.MATERIALS AND METHODS. An adult female thoracic anthropomorphic phantom was scanned using eight different clinical coronary CTA protocols that varied in detector configuration (320 × 0.5 mm or 64 × 0.5 mm), x-ray tube activation (full R-R, 65% R-R, or 70–80% R-R), use of tube current modulation, and use of breast shields. Direct dosimetry measurements were performed using Gafchromic film to determine the absorbed breast dose.RESULTS. Retrospective helical data acquisition using a 64-detector array and a full cardiac cycle without dose modulation or breast shielding is associated with an average absorbed breast dose of 82.9 mGy. Optimization of coronary CTA technique using a 320-detector array and a 70–80% cardiac phase reduces the absorbed breast dose by 78.9% to 17.5 mGy, whereas bre...


  • Quantification of arterial plaque and lumen density with MDCT

    by Narinder S. Paul, Joerg Blobel, Hany Kashani, Murray Rice, Ali Ursani

    Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT).Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5–5.0 mm in diameter with known CT attenuation nominal values ranging 50–800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0–5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function to demonstrate the relation between measured CT numbers and object diameters.Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in‐plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm.Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically generate a true assessment of measured CT number (HU) corresponding to plaque physical density . This is a significant development for the accurate, noninvasive classification of noncalcified arterial plaque.


  • Lung cancer screening using low-dose computed tomography in at-risk individuals: The Toronto experience

    by Ravi J. Menezes, Heidi C. Roberts, Narinder S. Paul, Maureen McGregor, Tae Bong Chung, Demetris Patsios, Gordon Weisbrod, Stephen Herman, Andre Pereira, Alexander McGregor, et al.


  • The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT

    by N S Paul, J Blobel, E Prezelj, P Burey, A Ursani, R J Menezes, H Kashani, J H Siewerdsen

    Increased pixel noise and streak artifact reduce CT image quality and limit the potential for radiation dose reduction during CT of the thoracic inlet. We propose to quantify the pixel noise of mediastinal structures in the thoracic inlet, during low-dose (LDCT) and ultralow-dose (uLDCT) thoracic CT, and assess the utility of new software (quantum denoising system and BOOST3D) in addressing these limitations. Twelve patients had LDCT (120 kV, 25 mAs) and uLDCT (120 kV, 10 mAs) images reconstructed initially using standard mediastinal and lung filters followed by the quantum denoising system (QDS) to reduce pixel noise and BOOST3D (B3D) software to correct photon starvation noise as follows: group 1 no QDS, no B3D; group 2 B3D alone; group 3 QDS alone and group 4 both QDS and B3D. Nine regions of interest (ROIs) were replicated on mediastinal anatomy in the thoracic inlet, for each patient resulting in 3456 data points to calculate pixel noise and attenuation. QDS reduced pixel noise by 18.4% (lung images) and 15.8% (mediastinal images) at 25 mAs. B3D reduced pixel noise by approximately 8% in the posterior thorax and in combination there was a 35.5% reduction in effective radiation dose (E) for LDCT (1.63-1.05 mSv) in lung images and 32.2% (1.55-1.05 mSv) in mediastinal images. The same combination produced 20.7% reduction (0.53-0.42 mSv) in E for uLDCT, for lung images and 17.3% (0.51-0.42) for mediastinal images. This quantitative analysis of image quality confirms the utility of dedicated processing software in targeting image noise and streak artifact in thoracic LDCT and uLDCT images taken in the thoracic inlet. This processing software potentiates substantial reductions in radiation dose during thoracic LDCT and uLDCT.