SWShing Wai Wong

Shing Wai Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shing Wai Wong has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing Cognitive Ergonomics in Robotic Surgery—A Narrative Review

    by Avni Agarwal, Zhen Hao Ang, Shing Wai Wong

    Robotic-assisted surgery (RAS) has transformed minimally invasive procedures by improving physical ergonomics, surgical field visualisation and instrument manipulation. However, RAS introduces unique cognitive load for the surgeon. Cognitive ergonomics aims to enhance the mental resources to optimise the interactions between surgeons and their environment, thereby improving the wellbeing and performance of surgeons and patient outcomes. Current evidence highlights that RAS redistributes, rather than eliminates, ergonomic burden from the physical to the mental domain. Subjective measurement tools remain the most widely used; however, physiological measures offer continuous and real-time data regarding cognitive workload fluctuations during surgery. Strategies to improve cognitive ergonomics include surgeon-level strategies, interface and system design alterations, operating room workflow optimisation, incorporation of artificial intelligence, and training and education. This narrative review summarises the current evidence regarding the mental demands associated with RAS, cognitive workload measures, the consequences of poor cognition, and emerging strategies to improve cognitive ergonomics in RAS.

  • Open Access

    Advanced Flexible Robotic Systems for the Early Diagnosis and Treatment of Cancer and Cardiovascular Diseases

    by Hermione Truong, Chi Cong Nguyen, Hannah Thuy Truong, Kefan Zhu, Adrienne Ji, James Davies, Emanuele Nicotra, Bibhu Sharma, Jingjing Wan, Patrick Pruscino, et al.

    Cardiovascular diseases including arrhythmias, structural heart defects, and vascular disorders and cancer remain leading causes of death worldwide. The complex anatomy and submillimeter scale of many vessels and luminal organs pose major challenges for diagnosis and treatment. Recent advances in flexible surgical robotics have transformed minimally invasive interventions by introducing compliant, steerable systems capable of precise navigation through natural orifices or percutaneous endovascular entry. These robots can reach previously inaccessible regions, enabling more accurate diagnosis and targeted therapy while reducing patient trauma compared to conventional rigid tools. However, flexible robotic designs must be carefully engineered to meet the unique requirements of each application, from navigating tortuous vasculature to delivering localized therapies. This review summarizes recent progress in flexible surgical robotics, focusing on innovations in actuation mechanisms, bio‐integrated sensing and electronics, AI‐assisted navigation and control, and friction‐reduction strategies that enhance dexterity, safety, and clinical outcomes. By critically analyzing current technologies and their limitations in cardiovascular and oncological contexts, the review identifies emerging opportunities and design challenges. It concludes with a discussion of future directions toward more intelligent, miniaturized, and clinically adaptable flexible robotic systems for precision medicine.

  • Open Access

    Surgical education reimagined: the convergence of learning theories and artificial intelligence

    by Frances Lee, Shing Wai Wong

    The integration of artificial intelligence (AI) into surgical education is transforming the way surgical skills and knowledge are developed. This article e


  • Vision & the Ageing Surgeon: A Review

    by Lloyd R. Kopecny, Ashish Agar, Shing Wai Wong

    Populations in the developed world are ageing and their surgeons are no exception. Accurate vision is essential for the surgeon to operate effectively, yet optimal vision has an expiry date in advancing age. This review examines the effects of ageing on the eye with particular focus on the visual changes of significance to senior surgeons who currently account for 20%–25% of the surgeon workforce. The major age‐related diseases of the eye, which include cataracts, glaucoma, age‐related macular degeneration and diabetic retinopathy, are surmised; together with physiologic ocular changes that accompany normal ageing, including loss of accommodation (presbyopia), reduced pupil size (senile miosis), reduced contrast sensitivity, and impaired binocular vision, amongst others. The aforementioned conditions may impair operative visualisation in the elderly surgeon and potentially impact surgical performance. Strategies and available technologies that support operative visualisation—particularly magnification aids, illumination systems and fluorescent dyes in surgery—are appraised with consideration to the senior surgeon who may be affected by the aforementioned visual changes associated with ageing. To inform minimum standards of visual function for safe surgical practice, future prospective studies are needed which report on individual surgeon‐related measures of visual function together with postoperative outcomes. This vein of future research will allow for an evidence‐based evaluation of proposed safety measures for which the data are currently lacking, thereby providing clarity regarding whether requisite age‐based visual assessments improve surgical outcomes, and if so, at what age and frequency should such evaluations take place.


  • Open Access

    Management of the Malignant Rectal Polyp—A Narrative Review

    by Zhen Hao Ang, Shing Wai Wong

    Purpose: The aim of this review is to provide a contemporary update on the current management approaches and options with specific considerations in malignant rectal polyps. Methods: A literature review was carried out in PubMed, Embase and Cochrane databases using the keywords “malignant” and “polyp*”. Only publications in English language were included. Results: Histopathological features including margins, depth of invasion, tumour grade, LVI and tumour budding determines the risk of lymph node metastasis in malignant polyps. Rectal malignant polyps should be considered differently compared to their colonic counterpart. A low threshold should be considered for utilising transrectal excision to fully excise the polyp and to assess the margins. The rates of complete pathological response associated with total neoadjuvant therapy as well as the advent of “watch and wait” adds to the complexity of managing malignant rectal polyps. Conclusions: The management of malignant colorectal polyps lies in risk-stratifying patients who will benefit from an oncological resection.


  • Open Access

    Effect of forearm compression sleeve on muscle fatigue during robotic surgery: a randomized controlled study

    by Shing Wai Wong, Allan Parkes, Ranah Lim, Mark Muhlmann, Richard Savdie, Philip Crowe

    Shing Wai Wong, Allan Parkes, Ranah Lim, Mark Muhlmann, Richard Savdie, Philip Crowe. Journal of Minimally Invasive Surgery 2025;28:11-8. https://doi.org/10.7602/jmis.2025.28.1.11


  • Open Access

    Enhancers and disruptors of effective communication during robot-assisted surgery: A multispecialty observation study

    by Shing Wai Wong, Kyaw Lin Htike, Surya Krishnan, Juman Farjo, Richard Savdie, Andrew Richards, Mark Muhlmann, Allan Parkes, Philip Crowe

    Background: The introduction of robotic surgery has challenged effective communication because of the separation of thesurgeon. The aim of this study was to investigate factors that may enhance or disrupt effective communication during roboticsurgery. Methods: An observational study of 32 robotic cases involving seven surgeons at Prince of Wales Private Hospitalwas conducted between February 2024 and July 2024. The primary measure were the frequency of enhancing or disruptingcommunication flow influencers. Welch's two-tailed unpaired t test was used to compare the following variables: surgeon,team familiarity, and hour-block of surgery. Results: The mean number of hourly communication enhancers was 3.7 ± 1.5for the principal investigator (PI) surgeon and 5.7 ± 3.1 for the other surgeons (P = 0.02), respectively. The mean number ofhourly communication disrupters was 2.0 ± 1.1 for the PI surgeon and 2.3 ± 1.8 for the other surgeons (P = 0.63),respectively. The statistically significant difference in communication enhancers between surgeons was confounded by theoperation duration and was abolished when only the first two hours of surgery were compared. The mean number of hourlycommunication enhancers was 4.15 ± 1.92 for the less familiar team and 5.81 ± 3.30 for the familiar team (P = 0.09),respectively, while the mean number of hourly communication disruptors was 2.00 ± 1.20 for the less familiar team and 2.42± 1.95 for the familiar team (P = 0.47). With regard to the hour-block of robotic console surgery time, analysis of varianceshowed statistical differences in the mean number of communication enhancers and disruptors, with P < 0.001 and P =0.004, respectively. Conclusion: The statistically significant reduction in the number of enhancing communication techniqueuses based on operation duration may be reflective of increased cognitive fatigue.

  • Open Access

    Enhancing ergonomics in robotic surgery—a review

    by Shing Wai Wong, Zhen Hao Ang, Philip Crowe

    The field of ergonomics is composed of three main domains: physical, cognitive, and organisational. The ergonomic advantages of robotic surgery (RS) have been well described in many studies. The majority of published studies on ergonomics and RS have not investigated interventions which may enhance the known ergonomic advantages or overcome the ergonomic disadvantages. This review will report on interventions during RS which can reduce visual fatigue, reduce musculoskeletal pain, enhance manipulation of robotic instruments (including avoidance of robotic arm clashes), offer haptic feedback, improve robotic skills to improve efficiency, improve cognition, and overcome workflow disruptions. Downgaze positioning, regular screen breaks, eye relaxation exercises, refractive error correction, lubricating eye drops use, and blink efficiency are interventions which have been used to reduce visual fatigue. Ergonomic training to encourage more frequent use of the clutch controller, taking microbreaks with targeted stretching, and resistance strengthening training are some interventions which can help reduce musculoskeletal pain. The manipulation benefits can be enhanced by optimal port placement and avoidance of external clashes. Addition of haptic feedback can improve precision and reduce grasping forces. Robotic surgical simulator training, coaching/proctoring, and video review are some methods which can enhance robotic skills and shorten the learning curve. Cognitive training can improve skills during the stages of motor learning. Organisational interventions can overcome workflow disruptions related to surgeon separation and reduced situation awareness.


  • Open Access

    A Review on the Form and Complexity of Human–Robot Interaction in the Evolution of Autonomous Surgery

    by Tangyou Liu, Jiaole Wang, Shing Wong, Andrew Razjigaev, Susann Beier, Shuhua Peng, Thanh Nho Do, Shuang Song, Dewei Chu, Chun Hui Wang, et al.

    As robotics and intelligence increasingly integrate into surgery, the pivotal role of human–robot interaction (HRI) in surgical procedures and outcomes becomes evident. However, debate rages over whether increasing robot autonomy will result in less human involvement. Some scholars assert that autonomy will reduce human participation, whereas others contend it will result in more complex interactions. To reveal the role of HRI in the evolution of autonomous surgery, this review systematically explores the HRI of robotic surgery with various levels of autonomy. The HRI is examined from both robotic science and clinical practice perspectives, incorporating relevant case studies. Two key components, intention detection and situation awareness, are especially concerned with a brief description of the interfaces and control strategies they rely on. Additional insights are drawn from analogous technologies in aviation, industrial robotics, and autonomous vehicles. The analysis suggests that HRI complexity tends to increase as the robot transitions from no autonomy to conditional autonomy and is predicted to subsequently decrease with a substantial shift in the interaction form when moving toward full autonomy. It is concluded by highlighting challenges from technical and clinical perspectives and delineating research trends in this rapidly evolving field.