JSJohn F. Seely

John F. Seely

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John F. Seely has a total of 129 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gamma ray spectra from targets irradiated by picosecond lasers

    by J.F. Seely, C.I. Szabo, Uri Feldman, Hui Chen, L.T. Hudson, A. Henins


  • Characterization of zone plate properties using monochromatic synchrotron radiation in the 2 to 20 nm wavelength range

    by John Seely, Benjawan Kjornrattanawanich, Leonid Goray, Yan Feng, James Bremer

    A zone plate composed of Mo zones having 4 mm outermost zone diameter, 100 nm outermost zone width, and supported on a silicon nitride membrane was characterized using monochromatic synchrotron radiation in the 2 to 20 nm wavelength range. The zero and first order efficiencies were measured and compared to ab initio calculations that account for the optical properties of the materials, the width and shape of the zones, and multiple-layer thin-film effects. It is shown that the thicknesses of the Mo zones and the membrane and the ratio of the zone width to zone period can be independently determined from the measured diffraction efficiencies in the zero and first orders and that the computational code can be used to reliably design zone plates that are optimized for applications such as solar irradiance monitors in the extreme ultraviolet region.


  • Energetic electron propagation in solid targets driven by the intense electric fields of femtosecond laser pulses

    by J. F. Seely, C. I. Szabo, P. Audebert, E. Brambrink

    An analytical model is used to interpret experimental data on the propagation of energetic electrons perpendicular to and parallel to the propagation direction of intense femtosecond laser pulses that are incident on solid targets. The pulses with ≈1020 W/cm2 intensity are incident normal onto a gadolinium or tungsten wire embedded in an aluminum substrate, and MeV electrons generated in the focal spot propagate along the laser direction into the irradiated wire. Electrons also propagate laterally from the focal spot through the aluminum substrate and into a dysprosium or hafnium spectator wire at a distance up to 1 mm from the irradiated wire. The ratio of the K shell emission from the spectator and irradiated wires is a measure of the numbers and energies of the MeV electrons propagating parallel to and perpendicular to the intense oscillating electric field of the laser pulse. It is found that the angular distribution of electrons from the focal spot is highly non-isotropic, and approximately twice as many electrons are driven by the electric field toward the spectator wire as into the irradiated wire. This quantitative result is consistent with the qualitative experimental observation that the oscillating electric field of an intense femtosecond laser pulse, when interacting with a heavy metal target, preferentially drives energetic electrons in the electric field direction as compared to perpendicular to the field.


  • Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range

    by Csilla I. Szabo, Uri Feldman, Stephen Seltzer, Lawrence T. Hudson, Michelle O’brien, Hye-Sook Park, John F. Seely

    Two quartz (10–11) crystals were cylindrically bent to a 25.4 cm radius of curvature and were mounted in identical Cauchois-type transmission spectrometers, and the crystal diffraction efficiencies were measured to 5% absolute accuracy using narrow bandwidth x-ray source fluences in the 20 to 80 keV energy range. The measured integrated reflectivity values were compared to calculations performed using a computational model that accounts for the diffraction geometry of the bent transmission crystal. These crystal calibrations enable the accurate measurement of absolute hard x-ray emission levels from laser-produced plasmas and other laboratory sources.


  • Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facility

    by J. F. Seely, C. I. Szabo, U. Feldman, L. T. Hudson, A. Henins, P. Audebert, E. Brambrink

    The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.


  • Spatial resolution of a hard x-ray CCD detector

    by John F. Seely, Nino R. Pereira, Bruce V. Weber, Joseph W. Schumer, John P. Apruzese, Lawrence T. Hudson, Csilla I. Szabo, Craig N. Boyer, Scott Skirlo

    The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70keV energy range. The detector had 20μm pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer’s Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95μm (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.


  • Lateral propagation of MeV electrons generated by femtosecond laser irradiation

    by J. F. Seely, C. I. Szabo, P. Audebert, E. Brambrink, E. Tabakhoff, L. T. Hudson

    The propagation of MeV electrons generated by intense (≈1020 W/cm2) femtosecond laser irradiation, in the lateral direction perpendicular to the incident laser beam, was studied using targets consisting of irradiated metal wires and neighboring spectator wires embedded in electrically conductive (aluminum) or resistive (Teflon) substrates. The K shell spectra in the energy range 40–60 keV from wires of Gd, Dy, Hf, and W were recorded by a transmission crystal spectrometer. The spectra were produced by 1s electron ionization in the irradiated wire and by energetic electron propagation through the substrate material to the spectator wire of a different metal. The electron range and energy were determined from the relative K shell emissions from the irradiated and spectator wires separated by varying substrate lateral distances of up to 1 mm. It was found that electron propagation through Teflon was inhibited, compared to aluminum, implying a relatively weak return current and incomplete space-charge neutralization. The energetic electron propagation in the direction parallel to the electric field of the laser beam was larger than perpendicular to the electric field. Energetic electron production was lower when directly irradiating aluminum or Teflon compared to irradiating the heavy metal wires. These experiments are important for the determination of the energetic electron production mechanism and for understanding lateral electron propagation that can be detrimental to fast-ignition fusion and hard x-ray backlighter radiography.


  • Radiometry and metrology of a phase zone plate measured by extreme ultraviolet synchrotron radiation

    by John F. Seely, Benjawan Kjornrattanawanich, James C. Bremer, Michael Kowalski, Yan Feng

    The diffraction efficiency, focal length, and other radiometric and metrology properties of a phase zone plate were measured by using monochromatic synchrotron radiation in the 7–18.5 nm wavelength range. The zone plate was composed of molybdenum zones having a 4 mm outer diameter and 70 nm nominal thickness and supported on a 100 nm thick silicon nitride membrane. The diffraction efficiency was enhanced by the phase shift of the radiation passing through the zones. The measured first-order efficiency was in good agreement with the calculated efficiency. The properties of the zone plate, particularly the small variation of the efficiency with off-axis angle, make it suitable for use in a radiometer to accurately measure the absolutely calibrated extreme ultraviolet emission from the Sun.


  • X-ray modulation transfer functions of photostimulable phosphor image plates and scanners

    by John F. Seely, Glenn E. Holland, Lawrence T. Hudson, Albert Henins

    The modulation transfer functions of two types of photostimulable phosphor image plates were determined in the 10 keV to 50 keV x-ray energy range using a resolution test pattern with up to 10 line pairs per mm (LP/mm) and a wavelength dispersive x-ray spectrometer. Techniques were developed for correcting for the partial transmittance of the high energy x rays through the lead bars of the resolution test pattern, and the modulation transfer function (MTF) was determined from the measured change in contrast with LP/mm values. The MTF was convolved with the slit function of the image plate scanner, and the resulting point spread functions (PSFs) were in good agreement with the observed shapes and widths of x-ray spectral lines and with the PSF derived from edge spread functions. The shapes and the full width at half-maximum (FWHM) values of the PSF curves of the Fuji Superior Resolution (SR) and Fuji Maximum Sensitivity (MS) image plate detectors, consisting of the image plate and the scanner, determined by the three methods gave consistent results: The SR PSF is Gaussian with 0.13 mm FWHM, and the MS PSF is Lorentzian with 0.19 mm FWHM. These techniques result in the accurate determination of the spatial resolution achievable using image plate and scanner combinations and enable the optimization of spatial resolution for x-ray spectroscopy and radiography.


  • Enhanced x-ray resolving power achieved behind the focal circles of Cauchois spectrometers

    by John F. Seely, Lawrence T. Hudson, Glenn E. Holland, Albert Henins

    Maintaining high resolving power is a primary challenge in hard x-ray spectroscopy of newly developed bright and transient x-ray sources such as laser-produced plasmas. To address this challenge, the line widths in x-ray spectra with energies in the 17 keV to 70 keV range were recorded by positioning the detectors on and behind the focal circles of Cauchois type transmission-crystal spectrometers. To analyze and understand the observed line widths, we developed a geometrical model that accounts for source broadening and various instrumental broadening mechanisms. The x-ray sources were laboratory Mo or W electron-bombarded anodes, and the spectra were recorded on photostimulable phosphor image plates. For these relatively small x-ray sources, it was found that when the detector was placed on or near the focal circle, the line widths were dominated by the effective spatial resolution of the detector. When the detector was positioned beyond the focal circle, the line widths were determined primarily by source-size broadening. Moreover, the separation between the spectral lines increased with distance behind the focal circle faster than the line widths, resulting in increased resolving power with distance. Contributions to line broadenings caused by the crystal thickness, crystal rocking curve width, geometrical aberrations, and natural widths of the x-ray transitions were in all cases smaller than detector and source broadening, but were significant for some spectrometer geometries. The various contributions to the line widths, calculated using simple analytical expressions, were in good agreement with the measured line widths for a variety of spectrometer and source conditions. These modeling and experimental results enable the design of hard x-ray spectrometers that are optimized for high resolving power and for the measurement of the x-ray source size from the line widths recorded behind the focal circle.