M. Bitter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
M. Bitter has a total of 633 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth W Hill
Princeton Plasma Physics Laboratory
44 shared publications S. von Goeler
Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543
31 shared publicationsH. Hsuan
21 shared publications- Peter Beiersdorfer
Physics Division, Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
17 shared publications B. Grek
Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543
13 shared publicationsM.G. Bell
13 shared publications
Latest Publications
- 26 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E333
A multi-cone x-ray imaging Bragg crystal spectrometer
This article describes a new x-ray imaging Bragg crystal spectrometer, which—in combination with a streak camera or a gated strip detector—can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. These unique imaging properties are obtained by bending the x-ray diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.
- 26 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E333
A multi-cone x-ray imaging Bragg crystal spectrometer
This article describes a new x-ray imaging Bragg crystal spectrometer, which—in combination with a streak camera or a gated strip detector—can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. These unique imaging properties are obtained by bending the x-ray diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.
- 3 August 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10) , 10E527
A new scheme for stigmatic x-ray imaging with large magnification
This paper describes a new x-ray scheme for stigmatic imaging. The scheme consists of one convex spherically bent crystal and one concave spherically bent crystal. The radii of curvature and Bragg reflecting lattice planes of the two crystals are properly matched to eliminate the astigmatism, so that the conditions for stigmatic imaging are met for a particular wavelength. The magnification is adjustable and solely a function of the two Bragg angles or angles of incidence. Although the choice of Bragg angles is constrained by the availability of crystals, this is not a severe limitation for the imaging of plasmas, since a particular wavelength can be selected from the bremsstrahlung continuum. The working principle of this imaging scheme has been verified with visible light. Further tests with x rays are planned for the near future.
- 3 August 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10) , 10E527
A new scheme for stigmatic x-ray imaging with large magnification
This paper describes a new x-ray scheme for stigmatic imaging. The scheme consists of one convex spherically bent crystal and one concave spherically bent crystal. The radii of curvature and Bragg reflecting lattice planes of the two crystals are properly matched to eliminate the astigmatism, so that the conditions for stigmatic imaging are met for a particular wavelength. The magnification is adjustable and solely a function of the two Bragg angles or angles of incidence. Although the choice of Bragg angles is constrained by the availability of crystals, this is not a severe limitation for the imaging of plasmas, since a particular wavelength can be selected from the bremsstrahlung continuum. The working principle of this imaging scheme has been verified with visible light. Further tests with x rays are planned for the near future.
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10E328
Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device
A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like and will provide ion temperature profiles with spatial and temporal resolutions of and , respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10E328
Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device
A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like and will provide ion temperature profiles with spatial and temporal resolutions of and , respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.- 26 August 2010
- Published by Office of Scientific and Technical Information (OSTI)
SXR Continuum Radiation Transmitted Through Metallic Filters: An Analytical Approach To Fast Electron Temperature Measurements
A new set of analytic formulae describes the transmission of soft X-ray (SXR) continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler, Rev. Sci. Instrum., 20, 599, (1999)]. The new analytic formulae can improve the interpretation of the experimental results and thus contribute in obtaining fast teperature measurements in between intermittent Thomson Scattering data.
- 26 August 2010
- Published by Office of Scientific and Technical Information (OSTI)
SXR Continuum Radiation Transmitted Through Metallic Filters: An Analytical Approach To Fast Electron Temperature Measurements
A new set of analytic formulae describes the transmission of soft X-ray (SXR) continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler, Rev. Sci. Instrum., 20, 599, (1999)]. The new analytic formulae can improve the interpretation of the experimental results and thus contribute in obtaining fast teperature measurements in between intermittent Thomson Scattering data.
- 1 June 2010
- Published by Office of Scientific and Technical Information (OSTI)
Imaging with Spherically Bent Crystals or Reflectors
This paper consists of two parts: Part I describes the working principle of a recently developed x-ray imaging crystal spectrometer, where the astigmatism of spherically bent crystals is being used with advantage to record spatially resolved spectra of highly charged ions for Doppler measurements of the ion-temperature and toroidal plasmarotation- velocity profiles in tokamak plasmas. This type of spectrometer was thoroughly tested on NSTX and Alcator C-Mod, and its concept was recently adopted for the design of the ITER crystal spectrometers. Part II describes imaging schemes, where the astigmatism has been eliminated by the use of matched pairs of spherically bent crystals or reflectors. These imaging schemes are applicable over a wide range of the electromagnetic radiation, which includes microwaves, visible light, EUV radiation, and x-rays. Potential applications with EUV radiation and x-rays are the diagnosis of laserproduced plasmas, imaging of biological samples with synchrotron radiation, and lithography.
- 1 June 2010
- Published by Office of Scientific and Technical Information (OSTI)
Imaging with Spherically Bent Crystals or Reflectors
This paper consists of two parts: Part I describes the working principle of a recently developed x-ray imaging crystal spectrometer, where the astigmatism of spherically bent crystals is being used with advantage to record spatially resolved spectra of highly charged ions for Doppler measurements of the ion-temperature and toroidal plasmarotation- velocity profiles in tokamak plasmas. This type of spectrometer was thoroughly tested on NSTX and Alcator C-Mod, and its concept was recently adopted for the design of the ITER crystal spectrometers. Part II describes imaging schemes, where the astigmatism has been eliminated by the use of matched pairs of spherically bent crystals or reflectors. These imaging schemes are applicable over a wide range of the electromagnetic radiation, which includes microwaves, visible light, EUV radiation, and x-rays. Potential applications with EUV radiation and x-rays are the diagnosis of laserproduced plasmas, imaging of biological samples with synchrotron radiation, and lithography.
- 19 May 2010
- Published by Office of Scientific and Technical Information (OSTI)
Design Parameters and Objectives of a High-Resolution X-ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)
A high-resolution X-ray imaging crystal spectrometer, whose instrumental concept was thoroughly tested on NSTX and Alcator C-Mod, is presently being designed for LHD. The instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of 1 cm and > 10 ms which are obtained by a tomographic inversion of the spectral data, using the stellarator equilibrium reconstruction codes, STELLOPT and PIES. Since the spectrometer will be equipped with radiation hardened, high count rate, PILATUS detectors,, it is expected to be operational for all experimental conditions on LHD, which include plasmas of high density and plasmas with auxiliary RF and neutral beam heating. The special design features required by the magnetic field structure at LHD will be described.
- 19 May 2010
- Published by Office of Scientific and Technical Information (OSTI)
Design Parameters and Objectives of a High-Resolution X-ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)
A high-resolution X-ray imaging crystal spectrometer, whose instrumental concept was thoroughly tested on NSTX and Alcator C-Mod, is presently being designed for LHD. The instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of 1 cm and > 10 ms which are obtained by a tomographic inversion of the spectral data, using the stellarator equilibrium reconstruction codes, STELLOPT and PIES. Since the spectrometer will be equipped with radiation hardened, high count rate, PILATUS detectors,, it is expected to be operational for all experimental conditions on LHD, which include plasmas of high density and plasmas with auxiliary RF and neutral beam heating. The special design features required by the magnetic field structure at LHD will be described.
- 20 November 2009
- Published by Office of Scientific and Technical Information (OSTI)
Lower Hybrid Heating and Current Drive on the Alcator C-Mod Tokamak
On the Alcator C-Mod tokamak, lower hybrid current drive (LHCD) is being used to modify the current profile with the aim of obtaining advanced tokamak (AT) performance in plasmas with parameters similar to those that would be required on ITER. To date, power levels in excess of 1 MW at a frequency of 4.6 GHz have been coupled into a variety of plasmas. Experiments have established that LHCD on C-Mod behaves globally as predicted by theory. Bulk current drive efficiencies, n20IlhR/Plh ~ 0.25, inferred from magnetics and MSE are in line with theory. Quantitative comparisons between local measurements, MSE, ECE and hard x-ray bremsstrahlung, and theory/simulation using the GENRAY, TORIC-LH CQL3D and TSC-LSC codes have been performed. These comparisons have demonstrated the off-axis localization of the current drive, its magnitude and location dependence on the launched n|| spectrum, and the use of LHCD during the current ramp to save volt-seconds and delay the peaking of the current profile. Broadening of the x-ray emission profile during ICRF heating indicates that the current drive location can be controlled by the electron temperature, as expected. In addition, an alteration in the plasma toroidal rotation profile during LHCD has been observed with a significantmore » rotation in the counter current direction. Notably, the rotation is accompanied by peaking of the density and temperature profiles on a current diffusion time scale inside of the half radius where the LH absorption is taking place.« less
- 20 November 2009
- Published by Office of Scientific and Technical Information (OSTI)
Lower Hybrid Heating and Current Drive on the Alcator C-Mod Tokamak
On the Alcator C-Mod tokamak, lower hybrid current drive (LHCD) is being used to modify the current profile with the aim of obtaining advanced tokamak (AT) performance in plasmas with parameters similar to those that would be required on ITER. To date, power levels in excess of 1 MW at a frequency of 4.6 GHz have been coupled into a variety of plasmas. Experiments have established that LHCD on C-Mod behaves globally as predicted by theory. Bulk current drive efficiencies, n20IlhR/Plh ~ 0.25, inferred from magnetics and MSE are in line with theory. Quantitative comparisons between local measurements, MSE, ECE and hard x-ray bremsstrahlung, and theory/simulation using the GENRAY, TORIC-LH CQL3D and TSC-LSC codes have been performed. These comparisons have demonstrated the off-axis localization of the current drive, its magnitude and location dependence on the launched n|| spectrum, and the use of LHCD during the current ramp to save volt-seconds and delay the peaking of the current profile. Broadening of the x-ray emission profile during ICRF heating indicates that the current drive location can be controlled by the electron temperature, as expected. In addition, an alteration in the plasma toroidal rotation profile during LHCD has been observed with a significantmore » rotation in the counter current direction. Notably, the rotation is accompanied by peaking of the density and temperature profiles on a current diffusion time scale inside of the half radius where the LH absorption is taking place.« less
- 24 March 2009
- Published by Office of Scientific and Technical Information (OSTI)
A Spatially Resolving X-ray Crystal Spectrometer for Measurement of Ion-temperature and Rotation-velocity Profiles on the AlcatorC-Mod Tokamak
A new spatially resolving x-ray crystal spectrometer capable of measuring continuous spatial profiles of high resolution spectra (λ/dλ > 6000) of He-like and H-like Ar Kα lines with good spatial (~1 cm) and temporal (~10 ms) resolutions has been installed on the Alcator C-Mod tokamak. Two spherically bent crystals image the spectra onto four two-dimensional Pilatus II pixel detectors. Tomographic inversion enables inference of local line emissivity, ion temperature (Ti), and toroidal plasma rotation velocity (vφ) from the line Doppler widths and shifts. The data analysis techniqu
- 24 March 2009
- Published by Office of Scientific and Technical Information (OSTI)
A Spatially Resolving X-ray Crystal Spectrometer for Measurement of Ion-temperature and Rotation-velocity Profiles on the AlcatorC-Mod Tokamak
A new spatially resolving x-ray crystal spectrometer capable of measuring continuous spatial profiles of high resolution spectra (λ/dλ > 6000) of He-like and H-like Ar Kα lines with good spatial (~1 cm) and temporal (~10 ms) resolutions has been installed on the Alcator C-Mod tokamak. Two spherically bent crystals image the spectra onto four two-dimensional Pilatus II pixel detectors. Tomographic inversion enables inference of local line emissivity, ion temperature (Ti), and toroidal plasma rotation velocity (vφ) from the line Doppler widths and shifts. The data analysis techniqu
- 1 January 2009
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 17 (2) , 153-160
Non-astigmatic imaging with matched pairs of spherically bent crystals or reflectors
This paper defines the exact conditions for the application of a previously proposed, general, non-astigmatic, imaging scheme, consisting of a matched pair of spherically bent crystals or reflectors, to x rays. These conditions lead to two specific experimental arrangements, of which one can provide large magnifications. Potential applications include the x-ray diagnosis of laser-produced plasmas and x-ray imaging of, e. g., biological samples, using the highly monochromatic radiation at synchrotron light sources. The results obtained for x rays are, however, valid for a wide spectrum of the electromagnetic radiation so that, for instance, an application of one of the imaging schemes to lithography in the EUV wavelength range should also be possible, if the spherically bent crystals are replaced by appropriate spherical reflectors. Also described is the design of an x-ray crystal spectrometer, which meets the here defined, necessary requirements for the observation of the x-ray spectra of helium-like argon.
- 1 January 2009
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 17 (2) , 153-160
Non-astigmatic imaging with matched pairs of spherically bent crystals or reflectors
This paper defines the exact conditions for the application of a previously proposed, general, non-astigmatic, imaging scheme, consisting of a matched pair of spherically bent crystals or reflectors, to x rays. These conditions lead to two specific experimental arrangements, of which one can provide large magnifications. Potential applications include the x-ray diagnosis of laser-produced plasmas and x-ray imaging of, e. g., biological samples, using the highly monochromatic radiation at synchrotron light sources. The results obtained for x rays are, however, valid for a wide spectrum of the electromagnetic radiation so that, for instance, an application of one of the imaging schemes to lithography in the EUV wavelength range should also be possible, if the spherically bent crystals are replaced by appropriate spherical reflectors. Also described is the design of an x-ray crystal spectrometer, which meets the here defined, necessary requirements for the observation of the x-ray spectra of helium-like argon.
- 17 March 2008
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 988 (1) , 155
Passive Spectroscopy Bolometers, Grating- And X-ray Imaging Crystal Spectrometers
This tutorial gives a brief introduction into passive spectroscopy and describes the working principles of bolometers, a high‐resolution grating spectrometer, and a novel X‐ray imaging crystal spectrometer, which is also of particular interest for profile measurements of the ion temperature and plasma rotation velocity on ITER and future burning plasma experiments.
- 17 March 2008
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 988 (1) , 155
Passive Spectroscopy Bolometers, Grating- And X-ray Imaging Crystal Spectrometers
This tutorial gives a brief introduction into passive spectroscopy and describes the working principles of bolometers, a high‐resolution grating spectrometer, and a novel X‐ray imaging crystal spectrometer, which is also of particular interest for profile measurements of the ion temperature and plasma rotation velocity on ITER and future burning plasma experiments.