Haleem J. Issaq
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Haleem J. Issaq has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Timothy D. Veenstra
Laboratory of Proteomics and Analytical Technologies, Advanced Technology Program, SAIC‐Frederick, Inc., NCI‐Frederick, Frederick, MD, USA
5 shared publicationsStephen D. Fox
Laboratory of Proteomics and Analytical Technologies, Advanced Technology Program, SAIC‐Frederick, Inc., NCI‐Frederick, Frederick, MD, USA
2 shared publicationsKing C. Chan
Laboratory of Proteomics and Analytical Technologies, Advanced Technology Program, SAIC‐Frederick, Inc., NCI‐Frederick, Frederick, MD, USA
1 shared publication- King Chan
Frederick National Laboratory for Cancer Research 8 Protein Characterization Laboratory, Cancer Research Technology Program , Frederick, Maryland
1 shared publication Que N. Van
Laboratory of Proteomics and Analytical Technologies, Advanced Technology Program, SAIC-Frederick, Inc, NCI-Frederick, MD 21702, USA
1 shared publicationRoni T. Falk
Epidemiology and Biostatistics Program, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD, USA
1 shared publication
Latest Publications
- 21 November 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (24) , 3484-3492
Global proteomics and metabolomics in cancer biomarker discovery
Chromatography and electrophoresis have been used for the last half‐century to separate small and large molecules. Advances in MS instrumentation and techniques for sample introduction into the mass analyzer (i.e. matrix‐assisted laser desorption/ionization and electrospray ionization), chromatography in all its formats and modes and two‐dimensional gel electrophoresis, including two‐dimensional difference gel electrophoresis, enabled the separation of complex biological mixtures, such as the proteome and the metabolome, in a biological sample. These advances have made it possible to identify compounds that can be used to discriminate between two samples taken from healthy and diseased individuals. The objective is to find proteins or metabolites that can be used as a clinical test for the early diagnosis, prognosis and monitoring of the disease and the outcome of therapy. In this manuscript, we present an overview of what has been achieved in the search for biomarkers, with emphasis on cancer, using separation science and MS.
- 21 November 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (24) , 3484-3492
Global proteomics and metabolomics in cancer biomarker discovery
Chromatography and electrophoresis have been used for the last half‐century to separate small and large molecules. Advances in MS instrumentation and techniques for sample introduction into the mass analyzer (i.e. matrix‐assisted laser desorption/ionization and electrospray ionization), chromatography in all its formats and modes and two‐dimensional gel electrophoresis, including two‐dimensional difference gel electrophoresis, enabled the separation of complex biological mixtures, such as the proteome and the metabolome, in a biological sample. These advances have made it possible to identify compounds that can be used to discriminate between two samples taken from healthy and diseased individuals. The objective is to find proteins or metabolites that can be used as a clinical test for the early diagnosis, prognosis and monitoring of the disease and the outcome of therapy. In this manuscript, we present an overview of what has been achieved in the search for biomarkers, with emphasis on cancer, using separation science and MS.
- 19 October 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (24) , 3619-3621
Is sarcosine a biomarker for prostate cancer?
Sarcosine was suggested in a letter to Nature in 2009 as a biomarker for prostate cancer. This communication reviews what has been accomplished to date to determine whether sarcosine is or is not a biomarker for prostate cancer that can replace prostate‐specific antigen tests.
- 19 October 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (24) , 3619-3621
Is sarcosine a biomarker for prostate cancer?
Sarcosine was suggested in a letter to Nature in 2009 as a biomarker for prostate cancer. This communication reviews what has been accomplished to date to determine whether sarcosine is or is not a biomarker for prostate cancer that can replace prostate‐specific antigen tests.
- 20 April 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (11) , 1268-1274
Quantitation of free and total bisphenol A in human urine using liquid chromatography‐tandem mass spectrometry
Bisphenol A (BPA) is employed in the synthesis of polycarbonate plastics and epoxy resins and is widely used in consumer products including as a coating for the inside of almost all food and beverage containers and thermal‐imaging paper. Bisphenol A is considered to have important health implications because it possesses weak estrogenic activity and can leach from storage containers resulting in its consumption by both humans and animals. It is metabolized in the body and excreted into urine as a glucuronide derivative. In this report, we present an accurate, selective, sensitive, and reproducible high‐performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method for the quantitation of BPA in human urine, which is not prone to exogenous contamination. BPA‐glucuronide is hydrolyzed enzymatically, extracted with toluene, derivatized with dansyl chloride, and the BPA‐(dansyl)2 derivative is analyzed using reversed‐phase HPLC/MS/MS. Calibration was linear to 50 ng/mL with a limit of quantitation of 50 pg/mL and a limit of detection of 5 pg/mL.
- 20 April 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (11) , 1268-1274
Quantitation of free and total bisphenol A in human urine using liquid chromatography‐tandem mass spectrometry
Bisphenol A (BPA) is employed in the synthesis of polycarbonate plastics and epoxy resins and is widely used in consumer products including as a coating for the inside of almost all food and beverage containers and thermal‐imaging paper. Bisphenol A is considered to have important health implications because it possesses weak estrogenic activity and can leach from storage containers resulting in its consumption by both humans and animals. It is metabolized in the body and excreted into urine as a glucuronide derivative. In this report, we present an accurate, selective, sensitive, and reproducible high‐performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method for the quantitation of BPA in human urine, which is not prone to exogenous contamination. BPA‐glucuronide is hydrolyzed enzymatically, extracted with toluene, derivatized with dansyl chloride, and the BPA‐(dansyl)2 derivative is analyzed using reversed‐phase HPLC/MS/MS. Calibration was linear to 50 ng/mL with a limit of quantitation of 50 pg/mL and a limit of detection of 5 pg/mL.
- 30 March 2011
- Published by Wiley in Electrophoresis
- Vol. 32 (9) , 967-975
Cancer biomarker discovery: Opportunities and pitfalls in analytical methods
Many diseases result in specific and characteristic changes in the chemical and biochemical profiles of biological fluids and tissues prior to development of clinical symptoms. These changes are often useful diagnostic and prognostic biomarkers. Identifying biomarkers that can be used for the early detection of cancer will result in more efficient treatments, reduction in suffering, and lower mortality rates. An ideal screening test should be non‐invasive with high sensitivity and specificity. Proteomic and metabolomic analyses of biological samples can reveal changes in abundance levels of metabolites and proteins that when validated and confirmed through clinical trials can function as clinical tests for early detection, diagnosis, monitoring disease progression, and predicting therapeutic response. While the past decade has seen great advancements in proteomics and metabolomics research producing potential biomarkers for cancer, most of the identified biomarkers have failed to replace existing clinical tests. To become a clinically approved test, a potential biomarker should be confirmed and validated using hundreds of specimens and should be reproducible, specific, and sensitive. A search of the scientific and medical literature indicates that many studies report the discovery of potential biomarkers without proper validation and/or they do not meet the above criteria. In this manuscript, we will discuss the successes and the pitfalls of biomarker research and comment on study and experimental design, which in most cases is lacking, resulting in suboptimal biomarkers.
- 30 March 2011
- Published by Wiley in Electrophoresis
- Vol. 32 (9) , 967-975
Cancer biomarker discovery: Opportunities and pitfalls in analytical methods
Many diseases result in specific and characteristic changes in the chemical and biochemical profiles of biological fluids and tissues prior to development of clinical symptoms. These changes are often useful diagnostic and prognostic biomarkers. Identifying biomarkers that can be used for the early detection of cancer will result in more efficient treatments, reduction in suffering, and lower mortality rates. An ideal screening test should be non‐invasive with high sensitivity and specificity. Proteomic and metabolomic analyses of biological samples can reveal changes in abundance levels of metabolites and proteins that when validated and confirmed through clinical trials can function as clinical tests for early detection, diagnosis, monitoring disease progression, and predicting therapeutic response. While the past decade has seen great advancements in proteomics and metabolomics research producing potential biomarkers for cancer, most of the identified biomarkers have failed to replace existing clinical tests. To become a clinically approved test, a potential biomarker should be confirmed and validated using hundreds of specimens and should be reproducible, specific, and sensitive. A search of the scientific and medical literature indicates that many studies report the discovery of potential biomarkers without proper validation and/or they do not meet the above criteria. In this manuscript, we will discuss the successes and the pitfalls of biomarker research and comment on study and experimental design, which in most cases is lacking, resulting in suboptimal biomarkers.
- 14 February 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (6) , 2394-2396
Comparison of Fluorescence, Laser-Induced Fluorescence, and Ultraviolet Absorbance Detection for Measuring HPLC Fractionated Protein/Peptide Mixtures
Proteomics is the study of all proteins in a biological sample. High-pressure liquid chromatography coupled online with mass spectrometry (HPLC/MS) is currently the method of choice for proteomic analysis. Proteins are extracted, separated at the protein or peptide level (after enzymatic digestion), and fractions are analyzed by HPLC/MS. Detection during off-line fractionation is generally conducted using UV−vis, which is not sensitive enough to distinguish fractions having the largest concentration of proteins/peptides and should not be combined prior to HPLC/MS. To overcome this deficiency, we utilize fluorescence or UV-laser induced fluorescence (UV-LIF) detection for measuring proteins/peptides during the off-line fractionation. Fluorescence detection allows low-abundance proteins/peptides that contain aromatic amino acids to be measured. In this study, peptide/protein samples fractionated using ion-exchange chromatography were detected using UV absorbance, fluorescence, and UV-LIF. The results indicated that fluorescence and UV-LIF were able to detect the lower abundance proteins/peptides to give a more representative chromatogram, allowing the analyst to decide which fractions should be combined prior to HPLC/tandem mass spectrometry (MS/MS) analysis.
- 14 February 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (6) , 2394-2396
Comparison of Fluorescence, Laser-Induced Fluorescence, and Ultraviolet Absorbance Detection for Measuring HPLC Fractionated Protein/Peptide Mixtures
Proteomics is the study of all proteins in a biological sample. High-pressure liquid chromatography coupled online with mass spectrometry (HPLC/MS) is currently the method of choice for proteomic analysis. Proteins are extracted, separated at the protein or peptide level (after enzymatic digestion), and fractions are analyzed by HPLC/MS. Detection during off-line fractionation is generally conducted using UV−vis, which is not sensitive enough to distinguish fractions having the largest concentration of proteins/peptides and should not be combined prior to HPLC/MS. To overcome this deficiency, we utilize fluorescence or UV-laser induced fluorescence (UV-LIF) detection for measuring proteins/peptides during the off-line fractionation. Fluorescence detection allows low-abundance proteins/peptides that contain aromatic amino acids to be measured. In this study, peptide/protein samples fractionated using ion-exchange chromatography were detected using UV absorbance, fluorescence, and UV-LIF. The results indicated that fluorescence and UV-LIF were able to detect the lower abundance proteins/peptides to give a more representative chromatogram, allowing the analyst to decide which fractions should be combined prior to HPLC/tandem mass spectrometry (MS/MS) analysis.
- 9 November 2010
- Published by Springer Nature in Current Urology Reports
- Vol. 12 (1) , 34-40
Metabolic Profiling for the Detection of Bladder Cancer
The development and progression of many human diseases often result in changes in gene expression and protein and metabolite concentrations. Changes at the protein and metabolite level often are detectable in biological fluids and tissues before the appearance of clinical symptoms, rendering them useful diagnostic and prognostic biomarkers. As with many conditions, the discovery of a sensitive and specific urinary biomarker for bladder cancer would save lives and reduce the suffering due to this condition. A number of potential urinary protein biomarkers for bladder cancer have been identified, but they lack the sensitivity and specificity required to replace cystoscopy and histopathology. We discuss the use of mass spectrometry and nuclear magnetic resonance spectroscopy for the detection of metabolites in biological samples, comment on their advantages and limitations, and discuss recently published work in urine metabolic profiling for bladder cancer detection.
- 9 November 2010
- Published by Springer Nature in Current Urology Reports
- Vol. 12 (1) , 34-40
Metabolic Profiling for the Detection of Bladder Cancer
The development and progression of many human diseases often result in changes in gene expression and protein and metabolite concentrations. Changes at the protein and metabolite level often are detectable in biological fluids and tissues before the appearance of clinical symptoms, rendering them useful diagnostic and prognostic biomarkers. As with many conditions, the discovery of a sensitive and specific urinary biomarker for bladder cancer would save lives and reduce the suffering due to this condition. A number of potential urinary protein biomarkers for bladder cancer have been identified, but they lack the sensitivity and specificity required to replace cystoscopy and histopathology. We discuss the use of mass spectrometry and nuclear magnetic resonance spectroscopy for the detection of metabolites in biological samples, comment on their advantages and limitations, and discuss recently published work in urine metabolic profiling for bladder cancer detection.