Jhon Paul Smith-Pardo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jhon Paul Smith-Pardo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Cristian D. Gonzalez
Universidad de los Andes
2 shared publications- Juan Carlos Reyes
Universidad de los Andes
2 shared publications Juan D. Sandoval
Universidad de los Andes
2 shared publications- Esteban Marcillo-Delgado
Graduate Student, Dept. of Civil and Environmental Engineering, Universidad de Los Andes, Bogotá 111711, Colombia
1 shared publication Francisco A. Galvis
Stanford University
1 shared publication- Francisco A. Galvis
Research Associate and Instructor, Dept. of Civil and Environmental Engineering, Universidad de los Andes, Bogotá, Colombia
1 shared publication
Latest Publications
- Open Access
- 18 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 8004
Visualization of Distributed Plasticity in Concrete Piles Using OpenSeesPy
Lumped plasticity models available in commercial software offer a limited resolution of damage distribution along structural members. This study presents an open-source workflow that combines force-based fiber elements in OpenSeesPy with automated 3D post-processing for visualizing distributed plasticity in reinforced concrete piles. A 60 cm diameter pile subjected to monotonic lateral loading is analyzed using both SAP2000’s default plastic hinges and OpenSeesPy fiber sections (Concrete02/Steel02). Although the fiber model incurs a runtime approximately 2.5 times greater, it captures the gradual spread of yielding and deterioration with improved fidelity. The presented workflow includes Python routines for interactive stress–strain visualization, facilitating the identification of critical sections and verification of strain limits. This approach offers a computationally feasible alternative for performance-based analysis with enhanced insight into member-level behavior. Because the entire workflow—from model definition through post-processing—is fully scripted in Python, any change to geometry, materials, or loading can be re-run in seconds, dramatically reducing the time taken to execute sensitivity analyses.
- 18 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 8004
Open AccessVisualization of Distributed Plasticity in Concrete Piles Using OpenSeesPy
Lumped plasticity models available in commercial software offer a limited resolution of damage distribution along structural members. This study presents an open-source workflow that combines force-based fiber elements in OpenSeesPy with automated 3D post-processing for visualizing distributed plasticity in reinforced concrete piles. A 60 cm diameter pile subjected to monotonic lateral loading is analyzed using both SAP2000’s default plastic hinges and OpenSeesPy fiber sections (Concrete02/Steel02). Although the fiber model incurs a runtime approximately 2.5 times greater, it captures the gradual spread of yielding and deterioration with improved fidelity. The presented workflow includes Python routines for interactive stress–strain visualization, facilitating the identification of critical sections and verification of strain limits. This approach offers a computationally feasible alternative for performance-based analysis with enhanced insight into member-level behavior. Because the entire workflow—from model definition through post-processing—is fully scripted in Python, any change to geometry, materials, or loading can be re-run in seconds, dramatically reducing the time taken to execute sensitivity analyses.
- 4 September 2023
- Published by Springer Nature
- p. 296-308
Experimental Assessment of Three Simple Techniques for the Seismic Retrofitting of Heritage Earthen Structures
- 4 September 2023
- Published by Springer Nature
- p. 296-308
Experimental Assessment of Three Simple Techniques for the Seismic Retrofitting of Heritage Earthen Structures
- 4 April 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (7) , 4193-4215
In-plane seismic behavior of full-scale earthen walls with openings retrofitted with timber elements and vertical tensors
- 4 April 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 17 (7) , 4193-4215
In-plane seismic behavior of full-scale earthen walls with openings retrofitted with timber elements and vertical tensors
- 1 August 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (8)
Assessment of the Effective Seismic Mass for Low-Rise Framed Shear Buildings Supporting Nearly Permanent Live Loads
This paper presents the development of a lumped-parameter model of multistory framed shear buildings supporting rigid blocks with the possibility to slide. After favorably comparing with results from finite-element analyses and shake table tests, the model was used to assess design provisions in regard to the treatment of live load as seismic weight. It was found that using the minimum live load percentage in current design standards may lead to unconservative drift estimates for buildings supporting heavy and nearly permanent live load objects and structures that are (1) designed for higher values, (2) located in regions of low-to-moderate seismic risk, or (3) base isolated. Results from a parametric study led to a design expression that allows determining the portion of the expected live load that is effective as seismic weight on the structure as a function of the object/floor interface’s friction coefficient and the maximum floor acceleration of the building alone. The adequacy of the design expression was confirmed through three-dimensional finite-element analyses of two- and four-story buildings supporting live load objects that could slide.- 1 August 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (8)
Assessment of the Effective Seismic Mass for Low-Rise Framed Shear Buildings Supporting Nearly Permanent Live Loads
This paper presents the development of a lumped-parameter model of multistory framed shear buildings supporting rigid blocks with the possibility to slide. After favorably comparing with results from finite-element analyses and shake table tests, the model was used to assess design provisions in regard to the treatment of live load as seismic weight. It was found that using the minimum live load percentage in current design standards may lead to unconservative drift estimates for buildings supporting heavy and nearly permanent live load objects and structures that are (1) designed for higher values, (2) located in regions of low-to-moderate seismic risk, or (3) base isolated. Results from a parametric study led to a design expression that allows determining the portion of the expected live load that is effective as seismic weight on the structure as a function of the object/floor interface’s friction coefficient and the maximum floor acceleration of the building alone. The adequacy of the design expression was confirmed through three-dimensional finite-element analyses of two- and four-story buildings supporting live load objects that could slide.- 1 July 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 23 (7)
Rectangular Footing Dimensions to Develop the Plastic Moment Capacity of RC Bridge Columns
This technical note presents charts that allow bridge engineers to quickly estimate the minimum footing dimensions, as controlled by the nominal (or ultimate) bearing capacity of the supporting soil, to develop the biaxial plastic moment capacity of corresponding columns. The design aids are applicable to rectangular, circular, and oval reinforced concrete (RC) columns with cross-sectional dimensions of up to 2.44 m (8 ft), longitudinal reinforcement ratios from 1 to 2%, transverse reinforcement ratios from 0.4 to 1.2%, concrete compressive strengths ( ) from 28 (4) to 42 MPa (6 ksi), and axial load levels between 0.05 and 0.2 .- 1 July 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 23 (7)
Rectangular Footing Dimensions to Develop the Plastic Moment Capacity of RC Bridge Columns
This technical note presents charts that allow bridge engineers to quickly estimate the minimum footing dimensions, as controlled by the nominal (or ultimate) bearing capacity of the supporting soil, to develop the biaxial plastic moment capacity of corresponding columns. The design aids are applicable to rectangular, circular, and oval reinforced concrete (RC) columns with cross-sectional dimensions of up to 2.44 m (8 ft), longitudinal reinforcement ratios from 1 to 2%, transverse reinforcement ratios from 0.4 to 1.2%, concrete compressive strengths ( ) from 28 (4) to 42 MPa (6 ksi), and axial load levels between 0.05 and 0.2 .- 12 August 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1235-1244
Post-Earthquake Repair and Improvements, San Vicente, Chile
The magnitude 8.8 earthquake of February 2010 in Chile dealt a heavy blow to the 600-meter (2,000-ft) wharf structure at Berths 1, 2, and 3 of the San Vicente Terminal Internacional in the Biobio region of Chile. Earthquake-induced liquefaction and lateral spreading in the upland fill and wharf slope resulted in permanent wharf lateral deflections in excess of 600 mm (24 in), along with associated damage to concrete piling and pile-to-cap connections. This paper presents the post-earthquake repair and rehabilitation program for the wharf structure. The proposed rehabilitation strategy consisted of two phases: first, a structural assessment of the post-earthquake conditions with recommendations for short-term repairs and restrictions on operating criteria, followed by a structural retrofit program designed to stiffen the existing structure and provide a new lateral-force resisting system. An innovative approach to the seismic retrofit was used, which incorporates a combination of new plumb piles behind the wharf with ground improvement to ensure ample lateral strength and ductility capacity of the structure. The wharf retrofit also included a new apron structure in front of the wharf, designed to improve the local stability of existing slender piling (impacted by P-delta effects), with the added benefit of providing support for future crane rail installation and increased dredge depth. Finally, a 200-meter (656-ft) finger pier extension was included in the program, bringing the structurally retrofitted 4-berth system to a total combined 800 meters in length, designed to the most current seismic design standards.
- 12 August 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1235-1244
Post-Earthquake Repair and Improvements, San Vicente, Chile
The magnitude 8.8 earthquake of February 2010 in Chile dealt a heavy blow to the 600-meter (2,000-ft) wharf structure at Berths 1, 2, and 3 of the San Vicente Terminal Internacional in the Biobio region of Chile. Earthquake-induced liquefaction and lateral spreading in the upland fill and wharf slope resulted in permanent wharf lateral deflections in excess of 600 mm (24 in), along with associated damage to concrete piling and pile-to-cap connections. This paper presents the post-earthquake repair and rehabilitation program for the wharf structure. The proposed rehabilitation strategy consisted of two phases: first, a structural assessment of the post-earthquake conditions with recommendations for short-term repairs and restrictions on operating criteria, followed by a structural retrofit program designed to stiffen the existing structure and provide a new lateral-force resisting system. An innovative approach to the seismic retrofit was used, which incorporates a combination of new plumb piles behind the wharf with ground improvement to ensure ample lateral strength and ductility capacity of the structure. The wharf retrofit also included a new apron structure in front of the wharf, designed to improve the local stability of existing slender piling (impacted by P-delta effects), with the added benefit of providing support for future crane rail installation and increased dredge depth. Finally, a 200-meter (656-ft) finger pier extension was included in the program, bringing the structurally retrofitted 4-berth system to a total combined 800 meters in length, designed to the most current seismic design standards.