Sven Beholz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sven Beholz has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Wolfgang Konertz
11 shared publicationsMichael Kessler
Department of Cardiovascular Surgery, Charité-University, Berlin Berlin, Germany
4 shared publications- Wolfgang Konertz
Department of Cardiovascular Surgery, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
4 shared publications - Herko Grubitzsch
Heart and Diabetes Centre Mecklenburg-Vorpommern, Clinic of Cardiothoracic and Vascular Surgery, Karlsburg, Germany
2 shared publications Liling Zheng
Department of Cardiovascular Surgery, Charité-University, Berlin Berlin, Germany
2 shared publicationsMartin Rusche
Department of Cardiovascular Surgery, Charité-University, Berlin Berlin, Germany
2 shared publications
Latest Publications
- 1 January 2009
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 56 (S 01) , V193
Routine implantation of stentless pericardial aortic valves: Clinical and early hemodynamic results in 662 patients
Objectives: The implantation of stentless porcine aortic valves may be technical demanding due to the stiffness of the prosthesic aortic wall. To investigate stentless pericardial prostheses for aortic valve replacement in the clinical routine. Methods: Patients requiring isolated or combined biological aortic valve replacement were included. Two bovine pericardial prostheses were implanted: the Pericarbon Freedom stentless valve using two suture lines at the annulus and for subcoronary fixation and, as a modification since 2004, the Freedom Solo valve using a unique supraannular implantation technique with a single continuous suture line. Results: From 2001 to 2008 in total 662 patients operated on by all members of the surgical staff were included; 413 received a Freedom valve and 249 a Solo valve, respectively. Mean age was 75±8 years, 354 were females. 362 (55%) patients underwent isolated valve replacement, in 300 patients concomitant procedures were performed. 65 (9.8%) were reoperations, primary or prosthesis endocarditis was the indication for surgery in 75 (11.3%) patients. Mean crossclamp time was 70±31 minutes in all patients and 55±25 minutes in isolated primary valve replacement. Mortality was 5.3% due to non valve related reasons. Conclusion: Stentless pericardial aortic valve prostheses allow safe and reliable aortic valve replacement in a routine fashion with excellent hemodynamic results and low mortality.
- 1 January 2009
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 56 (S 01) , V193
Routine implantation of stentless pericardial aortic valves: Clinical and early hemodynamic results in 662 patients
Objectives: The implantation of stentless porcine aortic valves may be technical demanding due to the stiffness of the prosthesic aortic wall. To investigate stentless pericardial prostheses for aortic valve replacement in the clinical routine. Methods: Patients requiring isolated or combined biological aortic valve replacement were included. Two bovine pericardial prostheses were implanted: the Pericarbon Freedom stentless valve using two suture lines at the annulus and for subcoronary fixation and, as a modification since 2004, the Freedom Solo valve using a unique supraannular implantation technique with a single continuous suture line. Results: From 2001 to 2008 in total 662 patients operated on by all members of the surgical staff were included; 413 received a Freedom valve and 249 a Solo valve, respectively. Mean age was 75±8 years, 354 were females. 362 (55%) patients underwent isolated valve replacement, in 300 patients concomitant procedures were performed. 65 (9.8%) were reoperations, primary or prosthesis endocarditis was the indication for surgery in 75 (11.3%) patients. Mean crossclamp time was 70±31 minutes in all patients and 55±25 minutes in isolated primary valve replacement. Mortality was 5.3% due to non valve related reasons. Conclusion: Stentless pericardial aortic valve prostheses allow safe and reliable aortic valve replacement in a routine fashion with excellent hemodynamic results and low mortality.
- Open Access
- 29 April 2008
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 3 (1) , 21
Concomitant ablation of atrial fibrillation in octogenarians: an observational study
Cardiac surgery is increasingly required in octogenarians. These patients frequently present atrial fibrillation (AF), a significant factor for stroke and premature death. During the last decade, AF ablation has become an effective procedure in cardiac surgery. Because the results of concomitant AF ablation in octogenarians undergoing cardiac surgery are still not clear, we evaluated the outcome in these patients.
- 29 April 2008
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 3 (1) , 21
Open AccessConcomitant ablation of atrial fibrillation in octogenarians: an observational study
Cardiac surgery is increasingly required in octogenarians. These patients frequently present atrial fibrillation (AF), a significant factor for stroke and premature death. During the last decade, AF ablation has become an effective procedure in cardiac surgery. Because the results of concomitant AF ablation in octogenarians undergoing cardiac surgery are still not clear, we evaluated the outcome in these patients.
- 1 January 2007
- Vol. 16 (1) , 49
The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.
The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacement (AVR) between 2001 and 2004. The Freedom SOLO valve was implanted in 30 patients using a supra-annular, subcoronary technique with one continuous subcoronary suture line (group FS). For comparison, the Pericarbon Freedom valve was implanted in 30 patients using an interrupted suture (group PFI), and in 30 patients using a continuous suture line at the inflow site (group PFC). Patient hemodynamics at discharge were investigated by monitoring echocardiographic peak and mean gradients, and regurgitation. The mean extracorporeal circulation time (75.5+/-22.7 min in FS; 83.7+/-21.0 min in PFC versus 110.9+/-31.4 min in PFI) and cross-clamp time (56.0+/-18.6 min in FS; 62.2+/-16.2 min in PFC versus 87.7 +/-25.4 min in PFI) were significantly shorter with the continuous implantation techniques. Hemodynamics were most favorable for the Freedom SOLO valve as compared to either implantation technique of the Pericarbon Freedom valve (mean gradient 7.4+/-4.6 mmHg in FS versus 10.6+/-6.0 mmHg in PFC and 11.0+/-5.7 mmHg in PFI). There were no paravalvular leakages or transvalvular regurgitations. The Freedom SOLO stentless valve is easy to implant and demonstrates superior early postoperative hemodynamics. Due to the reduced cross-clamp time, it also offers an attractive option in isolated and combined AVR.
- 1 January 2007
- Vol. 16 (1) , 49
The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.
The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacement (AVR) between 2001 and 2004. The Freedom SOLO valve was implanted in 30 patients using a supra-annular, subcoronary technique with one continuous subcoronary suture line (group FS). For comparison, the Pericarbon Freedom valve was implanted in 30 patients using an interrupted suture (group PFI), and in 30 patients using a continuous suture line at the inflow site (group PFC). Patient hemodynamics at discharge were investigated by monitoring echocardiographic peak and mean gradients, and regurgitation. The mean extracorporeal circulation time (75.5+/-22.7 min in FS; 83.7+/-21.0 min in PFC versus 110.9+/-31.4 min in PFI) and cross-clamp time (56.0+/-18.6 min in FS; 62.2+/-16.2 min in PFC versus 87.7 +/-25.4 min in PFI) were significantly shorter with the continuous implantation techniques. Hemodynamics were most favorable for the Freedom SOLO valve as compared to either implantation technique of the Pericarbon Freedom valve (mean gradient 7.4+/-4.6 mmHg in FS versus 10.6+/-6.0 mmHg in PFC and 11.0+/-5.7 mmHg in PFI). There were no paravalvular leakages or transvalvular regurgitations. The Freedom SOLO stentless valve is easy to implant and demonstrates superior early postoperative hemodynamics. Due to the reduced cross-clamp time, it also offers an attractive option in isolated and combined AVR.
- 1 January 2007
- Vol. 16 (1) , 91-2
Avoiding early partial valve thrombosis of the Pericarbon Freedom stentless valve.
Pericardial stentless valve prostheses have shown excellent results in aortic valve replacement. However, due to flexibility of the prosthetic material, immobilization and subsequent partial valve thrombosis may occur in case of non-symmetric sinuses of Valsalva. This report details an implantation technique designed to prevent stress on the non-coronary cusp of pericardial stentless prostheses, thereby avoiding this problem.
- 1 January 2007
- Vol. 16 (1) , 91-2
Avoiding early partial valve thrombosis of the Pericarbon Freedom stentless valve.
Pericardial stentless valve prostheses have shown excellent results in aortic valve replacement. However, due to flexibility of the prosthetic material, immobilization and subsequent partial valve thrombosis may occur in case of non-symmetric sinuses of Valsalva. This report details an implantation technique designed to prevent stress on the non-coronary cusp of pericardial stentless prostheses, thereby avoiding this problem.
- 1 May 2006
- Vol. 15 (3) , 429-32
Operative technique and early hemodynamic results with the Freedom Solo valve.
Stentless aortic valve prostheses usually require two separate suture lines. The Freedom Solo valve (Sorin Group, Saluggia, Italy), by using a minimized implantation technique, requires only a single running suture line of 4-0 polypropylene. Herein are reported the surgical experience and early hemodynamic results obtained with this new valve. Following annular decalcification, the Freedom Solo prosthesis was implanted in the supraannular aortic position in the sinuses of Valsalva of 82 patients (52 females, 30 males; mean age 76.6 +/- 7.0 years). Echocardiography was performed to monitor gradients and regurgitation. The logistic EuroSCORE was 12.8 +/- 9.9. Isolated aortic valve replacement was performed in 48 patients; concomitant procedures included coronary artery bypass grafting, mitral procedures, subvalvular myectomy, and atrial ablation. The mean valve size implanted was 26.4 +/- 2.1 mm, and cross-clamp time was 39.0 +/- 7.0 min in primary isolated valve replacement. Non-valve-related 30-day mortality was 3.6%. At discharge, hemodynamic parameters were favorable, with low peak (16.2 +/- 8.0 mmHg) and mean (8.3 +/- 4.5 mmHg) gradients, and without paravalvular leakage and only minimal regurgitation (grade < I degrees) in 10 patients. Supraannular implantation of the Freedom Solo stentless valve is safe and reliable, using a single suture line. The valve provides excellent hemodynamics at hospital discharge, without paravalvular leakage. The reduced cross-clamp time represents an attractive surgical alternative in elderly patients.
- 1 May 2006
- Vol. 15 (3) , 429-32
Operative technique and early hemodynamic results with the Freedom Solo valve.
Stentless aortic valve prostheses usually require two separate suture lines. The Freedom Solo valve (Sorin Group, Saluggia, Italy), by using a minimized implantation technique, requires only a single running suture line of 4-0 polypropylene. Herein are reported the surgical experience and early hemodynamic results obtained with this new valve. Following annular decalcification, the Freedom Solo prosthesis was implanted in the supraannular aortic position in the sinuses of Valsalva of 82 patients (52 females, 30 males; mean age 76.6 +/- 7.0 years). Echocardiography was performed to monitor gradients and regurgitation. The logistic EuroSCORE was 12.8 +/- 9.9. Isolated aortic valve replacement was performed in 48 patients; concomitant procedures included coronary artery bypass grafting, mitral procedures, subvalvular myectomy, and atrial ablation. The mean valve size implanted was 26.4 +/- 2.1 mm, and cross-clamp time was 39.0 +/- 7.0 min in primary isolated valve replacement. Non-valve-related 30-day mortality was 3.6%. At discharge, hemodynamic parameters were favorable, with low peak (16.2 +/- 8.0 mmHg) and mean (8.3 +/- 4.5 mmHg) gradients, and without paravalvular leakage and only minimal regurgitation (grade < I degrees) in 10 patients. Supraannular implantation of the Freedom Solo stentless valve is safe and reliable, using a single suture line. The valve provides excellent hemodynamics at hospital discharge, without paravalvular leakage. The reduced cross-clamp time represents an attractive surgical alternative in elderly patients.
- 1 April 2006
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 14 (2) , 128-133
Continuous Suture Technique for Freedom Stentless Valve: Reduced Crossclamp Time
The Pericarbon Freedom stentless valve has shown excellent hemodynamics. A continuous suture technique at the inflow site may reduce cardiopulmonary bypass and crossclamp times and affect postoperative hemodynamics. In a prospective case-matched study, interrupted and continuous suture line techniques were used in 68 and 71 patients, respectively. Isolated valve replacement was performed in 70.4% of the continuous suture group and 67.6% of the interrupted suture group. Hemodynamic data were obtained by echocardiography (mean and peak gradients, regurgitation) at discharge and after 1 year. Overall mortality was 5.0% and due to non-valve-related causes. Bypass and crossclamp times were shorter by 22.4 and 20.6 min, respectively, in the continuous suture group. The suture technique at the inflow site did not result in significant differences in the mean (11.8 ± 6.3 vs. 12.5 ± 6.2 mm Hg) or peak gradients (21.0 ± 9.6 vs. 22.0 ± 10.9 mm Hg), or degree of regurgitation. Follow-up showed a further decrease in the gradients.
- 1 April 2006
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 14 (2) , 128-133
Continuous Suture Technique for Freedom Stentless Valve: Reduced Crossclamp Time
The Pericarbon Freedom stentless valve has shown excellent hemodynamics. A continuous suture technique at the inflow site may reduce cardiopulmonary bypass and crossclamp times and affect postoperative hemodynamics. In a prospective case-matched study, interrupted and continuous suture line techniques were used in 68 and 71 patients, respectively. Isolated valve replacement was performed in 70.4% of the continuous suture group and 67.6% of the interrupted suture group. Hemodynamic data were obtained by echocardiography (mean and peak gradients, regurgitation) at discharge and after 1 year. Overall mortality was 5.0% and due to non-valve-related causes. Bypass and crossclamp times were shorter by 22.4 and 20.6 min, respectively, in the continuous suture group. The suture technique at the inflow site did not result in significant differences in the mean (11.8 ± 6.3 vs. 12.5 ± 6.2 mm Hg) or peak gradients (21.0 ± 9.6 vs. 22.0 ± 10.9 mm Hg), or degree of regurgitation. Follow-up showed a further decrease in the gradients.
- 9 February 2006
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 54 (S 1) , PP_36
The Sorin Freedom Solo Valve: Early experience with a supraannular implantion technique of a new pericardial stentless valve
Objectives: To report on the experience with a supraannular implantation technique and early hemodynamic results of the new Freedom Solo valve (Sorin Group, Saluggia, Italy). Methods: After annular decalcification the prosthesis was implanted in a supraannular aortic position in the sinuses of valsalva using a single running suture line of polypropylene 4–0. Echocardiography was performed to observe gradients and regurgitation. Results: In 69 patients age was 77.7±6.7 years, 20 patients were male. Logistic EuroSCORE was 13.4±10.7. Isolated aortic valve replacement was performed in 40 patients; concomittant procedures covered CABG, mitral procedures, subvalvular myectomy and atrial ablations. Valve size was 26.1±2.2mm, crossclamp time 40.6±8.1 minutes in isolated valve replacement. 30 day mortality was 2.9% due to one myocardial infarction and one mesenteric infarction. Hemodynamics at discharge were favoreable with low peak and mean gradients and without paravalvular leakages and only minimal regurgitation (Conclusions: The supraannular implantation technique of the new Freedom Solo stentless valve is safe and reliable using a single suture line. The valve provides excellent hemodynamics at discharge without paravalvular leakages.
- 9 February 2006
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 54 (S 1) , PP_36
The Sorin Freedom Solo Valve: Early experience with a supraannular implantion technique of a new pericardial stentless valve
Objectives: To report on the experience with a supraannular implantation technique and early hemodynamic results of the new Freedom Solo valve (Sorin Group, Saluggia, Italy). Methods: After annular decalcification the prosthesis was implanted in a supraannular aortic position in the sinuses of valsalva using a single running suture line of polypropylene 4–0. Echocardiography was performed to observe gradients and regurgitation. Results: In 69 patients age was 77.7±6.7 years, 20 patients were male. Logistic EuroSCORE was 13.4±10.7. Isolated aortic valve replacement was performed in 40 patients; concomittant procedures covered CABG, mitral procedures, subvalvular myectomy and atrial ablations. Valve size was 26.1±2.2mm, crossclamp time 40.6±8.1 minutes in isolated valve replacement. 30 day mortality was 2.9% due to one myocardial infarction and one mesenteric infarction. Hemodynamics at discharge were favoreable with low peak and mean gradients and without paravalvular leakages and only minimal regurgitation (Conclusions: The supraannular implantation technique of the new Freedom Solo stentless valve is safe and reliable using a single suture line. The valve provides excellent hemodynamics at discharge without paravalvular leakages.
- 1 February 2006
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 14 (1) , 10-13
Low-Prime System Minimizes Transfusions and Hemodilution in Coronary Bypass
Standard heart-lung machines lead to substantial hemodilution with associated impaired organ function and increased need for blood transfusions. The aim of this study was to evaluate the effect of the new PRECiSe low prime volume system on perioperative myocardial damage, hemodilution, and transfusions. In a case-matched prospective study, 40 patients undergoing coronary artery bypass surgery using PRECiSe were compared with 40 patients on a standard heart-lung machine. In the PRECiSe group, the prime volume was significantly reduced, resulting in less hemodilution and transfusion requirements during and after extracorporeal circulation: only 10% of patients needed transfusions vs. 35% in the control group, with an average transfusion need of 0.16 vs. 1.25 units. There were no significant differences in perioperative cardiac-specific enzymes. The PRECiSe system was considered safe and effective for coronary artery bypass surgery.
- 1 February 2006
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 14 (1) , 10-13
Low-Prime System Minimizes Transfusions and Hemodilution in Coronary Bypass
Standard heart-lung machines lead to substantial hemodilution with associated impaired organ function and increased need for blood transfusions. The aim of this study was to evaluate the effect of the new PRECiSe low prime volume system on perioperative myocardial damage, hemodilution, and transfusions. In a case-matched prospective study, 40 patients undergoing coronary artery bypass surgery using PRECiSe were compared with 40 patients on a standard heart-lung machine. In the PRECiSe group, the prime volume was significantly reduced, resulting in less hemodilution and transfusion requirements during and after extracorporeal circulation: only 10% of patients needed transfusions vs. 35% in the control group, with an average transfusion need of 0.16 vs. 1.25 units. There were no significant differences in perioperative cardiac-specific enzymes. The PRECiSe system was considered safe and effective for coronary artery bypass surgery.
- 1 January 2006
- Vol. 100 (3) , 197-201
[Customer satisfaction with a quality management system according to DIN EN ISO 9001:2000: Increase in the satisfaction of cooperating clinics].
The evaluation of customers' satisfaction is elementary for any quality management system. In our university cardiac surgery unit that has been certified according to DIN EN ISO 9001:2000 the influence of repeated evaluation of the referring physicians' satisfaction conducted in the course of three consecutive years on structures and processes in the scope of the quality management system was examined. Customers' satisfaction with the possibility of access to the department could be increased by targeted interventions. Further interventions in the field of documentation led to a measurable increase in satisfaction with postoperative communication. Repeated annual evaluation of the satisfaction of referring physicians has proved to be a valuable tool in the process of continuous quality improvement.
- 1 January 2006
- Vol. 100 (3) , 197-201
[Customer satisfaction with a quality management system according to DIN EN ISO 9001:2000: Increase in the satisfaction of cooperating clinics].
The evaluation of customers' satisfaction is elementary for any quality management system. In our university cardiac surgery unit that has been certified according to DIN EN ISO 9001:2000 the influence of repeated evaluation of the referring physicians' satisfaction conducted in the course of three consecutive years on structures and processes in the scope of the quality management system was examined. Customers' satisfaction with the possibility of access to the department could be increased by targeted interventions. Further interventions in the field of documentation led to a measurable increase in satisfaction with postoperative communication. Repeated annual evaluation of the satisfaction of referring physicians has proved to be a valuable tool in the process of continuous quality improvement.
- 1 December 2005
- Published by IMR Press in The Heart Surgery Forum
- Vol. 8 (6) , E409-E411
Recommendations for the Implantation of the Pericarbon Freedom Stentless Valve
Based on our experience of 1000 subcoronary implants of the Sorin Pericarbon Freedom stentless valve, we give recommendations for the exact implantation technique. This article illustrates basic issues in the implantation technique with respect to continuous and interrupted suture to enable beginners and experienced surgeons to avoid some of the pitfalls. Additional remarks about sizing and early intraoperative echocardiographic findings complete this technical overview.
- 1 December 2005
- Published by IMR Press in The Heart Surgery Forum
- Vol. 8 (6) , E409-E411
Recommendations for the Implantation of the Pericarbon Freedom Stentless Valve
Based on our experience of 1000 subcoronary implants of the Sorin Pericarbon Freedom stentless valve, we give recommendations for the exact implantation technique. This article illustrates basic issues in the implantation technique with respect to continuous and interrupted suture to enable beginners and experienced surgeons to avoid some of the pitfalls. Additional remarks about sizing and early intraoperative echocardiographic findings complete this technical overview.