Javad Tavakoli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Javad Tavakoli has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Arthur Kney
Civil and Environmental Engineering , Easton, PA, USA
1 shared publicationCatriona M. Duncanson
Department of Biology,1 Department of Chemical Engineering, Lafayette College, Easton, Pennsylvania 18042,2 Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente (CEPIS), Lima 100, Peru3
1 shared publicationDaniel J. Connolly
Department of Biology,1 Department of Chemical Engineering, Lafayette College, Easton, Pennsylvania 18042,2 Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente (CEPIS), Lima 100, Peru3
1 shared publicationDongye Zhao
Civil Engineering , Auburn University , Auburn, AL, USA
1 shared publication- L. Savadkouhi
Mechanical Research Institute, IROST, Tehran 19788-76114, IR Iran
1 shared publication Laurie F. Caslake
Department of Biology,1 Department of Chemical Engineering, Lafayette College, Easton, Pennsylvania 18042,2 Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente (CEPIS), Lima 100, Peru3
1 shared publication
Latest Publications
- 7 June 2010
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 132 (9) , 092801
Performance and Combustion Characteristics of OM314 Diesel Engine Fueled With DME: A Theoretical and Experimental Analysis
Use of dimethyl ether (DME) as a diesel fuel alternative has been increased due to the unique combustion characteristics of this oxygenated fuel. We have investigated performance and combustion characteristics of a naturally aspirated diesel engine using DME as the main fuel. In the experimental part of this work, OM314 direct-injection diesel engine was used as a base engine. A comprehensive full cycle was coupled with a multizone combustion model to simulate performance characteristics of the engine. Results of the volumetric efficiency showed that the highest brake torque was achievable in midspeed range. The power speed diagram showed that the brake torque tended to be much higher for diesel fuel than for DME when the engine speed was less than 1900 rpm. However, in engine speeds higher than 1900 rpm, brake torque in DME mode of operation was larger. Calculated emission results also suggested that negligible soot is produced in DME mode operation.
- 7 June 2010
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 132 (9) , 092801
Performance and Combustion Characteristics of OM314 Diesel Engine Fueled With DME: A Theoretical and Experimental Analysis
Use of dimethyl ether (DME) as a diesel fuel alternative has been increased due to the unique combustion characteristics of this oxygenated fuel. We have investigated performance and combustion characteristics of a naturally aspirated diesel engine using DME as the main fuel. In the experimental part of this work, OM314 direct-injection diesel engine was used as a base engine. A comprehensive full cycle was coupled with a multizone combustion model to simulate performance characteristics of the engine. Results of the volumetric efficiency showed that the highest brake torque was achievable in midspeed range. The power speed diagram showed that the brake torque tended to be much higher for diesel fuel than for DME when the engine speed was less than 1900 rpm. However, in engine speeds higher than 1900 rpm, brake torque in DME mode of operation was larger. Calculated emission results also suggested that negligible soot is produced in DME mode operation.
- 1 August 2006
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 41 (11) , 2555-2574
Removal of Perchlorate from Contaminated Water Using a Regenerable Polymeric Ligand Exchanger
A polymeric ligand exchanger (PLE), DOW 3 N‐Cu, has been investigated for perchlorate (ClO4 −) removal from contaminated water. Batch kinetic tests revealed that the perchlorate sorption equilibrium for DOW 3 N‐Cu can be reached within 20 hours and perchlorate removal by DOW 3 N‐Cu follows standard ion exchange stoichiometry. Fixed‐bed column runs showed that 12,388 bed volumes of perchlorate‐free water can be obtained when DOW 3 N‐Cu was used to treat a simulated contaminated water with an influent perchlorate concentration of 200 µg/L. It was found that the regeneration of spent DOW 3 N‐Cu is pH dependent. It was shown that addition of ethanol and a surfactant Tween 80 to a 4% NaCl/2% NaOH regenerant solution increased the regeneration efficiency of spent DOW 3 N‐Cu by 11 and 5 percent, respectively. Nearly 90% of perchlorate capacity of saturated DOW 3 N‐Cu was recovered using 35 bed volumes of a regenerant containing 4% (w/w) NaCl, 2% NaOH, 5% Tween 80, and 5% ethanol.
- 1 August 2006
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 41 (11) , 2555-2574
Removal of Perchlorate from Contaminated Water Using a Regenerable Polymeric Ligand Exchanger
A polymeric ligand exchanger (PLE), DOW 3 N‐Cu, has been investigated for perchlorate (ClO4 −) removal from contaminated water. Batch kinetic tests revealed that the perchlorate sorption equilibrium for DOW 3 N‐Cu can be reached within 20 hours and perchlorate removal by DOW 3 N‐Cu follows standard ion exchange stoichiometry. Fixed‐bed column runs showed that 12,388 bed volumes of perchlorate‐free water can be obtained when DOW 3 N‐Cu was used to treat a simulated contaminated water with an influent perchlorate concentration of 200 µg/L. It was found that the regeneration of spent DOW 3 N‐Cu is pH dependent. It was shown that addition of ethanol and a surfactant Tween 80 to a 4% NaCl/2% NaOH regenerant solution increased the regeneration efficiency of spent DOW 3 N‐Cu by 11 and 5 percent, respectively. Nearly 90% of perchlorate capacity of saturated DOW 3 N‐Cu was recovered using 35 bed volumes of a regenerant containing 4% (w/w) NaCl, 2% NaOH, 5% Tween 80, and 5% ethanol.
- 1 February 2004
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 70 (2) , 1145-1151
Disinfection of Contaminated Water by Using Solar Irradiation
Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log 10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log 10 U and disinfected approximately 1 liter of water in 30 min.
- 1 February 2004
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 70 (2) , 1145-1151
Disinfection of Contaminated Water by Using Solar Irradiation
Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log 10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log 10 U and disinfected approximately 1 liter of water in 30 min.