Pras Pathmanathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pras Pathmanathan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- David J. Gavaghan
University of Oxford
5 shared publications - Stephen Jonathan Chapman
University of Oxford
5 shared publications Jonathan P. Whiteley
Oxford University, Computing Laboratory, Parks Road, Oxford, OX1 3QD, U.K.
3 shared publications- Gary Richard Mirams
Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, United Kingdom
2 shared publications - Joe Pitt-Francis
Department of Computer Science, University of Oxford, Oxford, Oxfordshire, UK
2 shared publications - Jonathan Cooper
University College London , London , UK
2 shared publications
Latest Publications
- 24 March 2011
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 27 (11) , 1751-1770
The significant effect of the choice of ionic current integration method in cardiac electro‐physiological simulations
Finite element (FE) cardiac electro‐physiology solvers commonly have ionic current determined at mesh nodes but required element interiors. We consider two interpolation approaches: (i) ionic current interpolation (ICI), where nodal ionic currents are linearly interpolated into the element and (ii) state variable interpolation (SVI), where cell model state variables are interpolated instead, from which the ionic current is evaluated. We explain why SVI leads to a method which is massively more computationally demanding than ICI (more than might originally be expected), and then demonstrate that the difference in results can be surprisingly large even on what are generally considered suitably fine meshes. We explain why the conduction velocity in ICI simulations is generally too large, identify how ICI can give ‘accidentally’ accurate conduction velocities through two particular sources of error balancing, and illustrate how the difference between ICI and SVI can be huge in anisotropic problems. We also characterize the ICI/SVI difference over a range of cell models, in terms of model upstroke‐velocity and formulation of the fast sodium current. Finally, we propose and evaluate a hybrid method which provides the accuracy of SVI, while retaining the efficiency of ICI. Copyright © 2011 John Wiley & Sons, Ltd.
- 24 March 2011
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 27 (11) , 1751-1770
The significant effect of the choice of ionic current integration method in cardiac electro‐physiological simulations
Finite element (FE) cardiac electro‐physiology solvers commonly have ionic current determined at mesh nodes but required element interiors. We consider two interpolation approaches: (i) ionic current interpolation (ICI), where nodal ionic currents are linearly interpolated into the element and (ii) state variable interpolation (SVI), where cell model state variables are interpolated instead, from which the ionic current is evaluated. We explain why SVI leads to a method which is massively more computationally demanding than ICI (more than might originally be expected), and then demonstrate that the difference in results can be surprisingly large even on what are generally considered suitably fine meshes. We explain why the conduction velocity in ICI simulations is generally too large, identify how ICI can give ‘accidentally’ accurate conduction velocities through two particular sources of error balancing, and illustrate how the difference between ICI and SVI can be huge in anisotropic problems. We also characterize the ICI/SVI difference over a range of cell models, in terms of model upstroke‐velocity and formulation of the fast sodium current. Finally, we propose and evaluate a hybrid method which provides the accuracy of SVI, while retaining the efficiency of ICI. Copyright © 2011 John Wiley & Sons, Ltd.
- 12 July 2010
- Published by Oxford University Press (OUP) in Quarterly Journal of Mechanics and Applied Mathematics
- Vol. 63 (3) , 375-399
Cardiac Electromechanics: The Effect of Contraction Model on the Mathematical Problem and Accuracy of the Numerical Scheme
Models of cardiac electromechanics usually contain a contraction model determining the active tension induced at the cellular level and the equations of nonlinear elasticity to determine tissue deformation in response to this active tension. All contraction models are dependent on cardiac electrophysiology but can also be dependent on the stretch and stretch rate in the fibre direction. This fundamentally affects the mathematical problem being solved, through classification of the governing partial differential equations, which affects numerical schemes that can be used to solve the governing equations. We categorise contraction models into three types, and for each consider questions such as classification and the most appropriate choice from two numerical methods (the explicit and implicit schemes). In terms of mathematical classification, we consider the question of strong ellipticity of the total strain energy (important for precluding ‘unnatural’ material behaviour) for stretch-rate-independent contraction models; whereas for stretch-rate-dependent contraction models, we introduce a corresponding third-order problem and explain how certain choices of boundary condition could lead to constraints on allowable initial condition. In terms of suitable numerical methods, we show that an explicit approach (where the contraction model is integrated in the time step prior to the bulk deformation being computed) is (i) appropriate for stretch-independent contraction models; (ii) only conditionally stable, with the stability criterion independent of time step, for contractions models which just depend on stretch (but not stretch rate) and (iii) inappropriate for stretch-rate-dependent models.
- 12 July 2010
- Published by Oxford University Press (OUP) in Quarterly Journal of Mechanics and Applied Mathematics
- Vol. 63 (3) , 375-399
Cardiac Electromechanics: The Effect of Contraction Model on the Mathematical Problem and Accuracy of the Numerical Scheme
Models of cardiac electromechanics usually contain a contraction model determining the active tension induced at the cellular level and the equations of nonlinear elasticity to determine tissue deformation in response to this active tension. All contraction models are dependent on cardiac electrophysiology but can also be dependent on the stretch and stretch rate in the fibre direction. This fundamentally affects the mathematical problem being solved, through classification of the governing partial differential equations, which affects numerical schemes that can be used to solve the governing equations. We categorise contraction models into three types, and for each consider questions such as classification and the most appropriate choice from two numerical methods (the explicit and implicit schemes). In terms of mathematical classification, we consider the question of strong ellipticity of the total strain energy (important for precluding ‘unnatural’ material behaviour) for stretch-rate-independent contraction models; whereas for stretch-rate-dependent contraction models, we introduce a corresponding third-order problem and explain how certain choices of boundary condition could lead to constraints on allowable initial condition. In terms of suitable numerical methods, we show that an explicit approach (where the contraction model is integrated in the time step prior to the bulk deformation being computed) is (i) appropriate for stretch-independent contraction models; (ii) only conditionally stable, with the stability criterion independent of time step, for contractions models which just depend on stretch (but not stretch rate) and (iii) inappropriate for stretch-rate-dependent models.
- 1 June 2010
- Published by Elsevier in Progress in Biophysics and Molecular Biology
- Vol. 102 (2-3) , 136-155
A numerical guide to the solution of the bidomain equations of cardiac electrophysiology
- 1 June 2010
- Published by Elsevier in Progress in Biophysics and Molecular Biology
- Vol. 102 (2-3) , 136-155
A numerical guide to the solution of the bidomain equations of cardiac electrophysiology
- 1 February 2010
- Published by Wiley in Journal of Applied Mechanics
- Vol. 77 (3) , 034501
A Note on the Effect of the Choice of Weak Form on GMRES Convergence for Incompressible Nonlinear Elasticity Problems
The generalized minimal residual (GMRES) method is a common choice for solving the large nonsymmetric linear systems that arise when numerically computing solutions of incompressible nonlinear elasticity problems using the finite element method. Analytic results on the performance of GMRES are available on linear problems such as linear elasticity or Stokes’ flow (where the matrices in the corresponding linear systems are symmetric), or on the nonlinear problem of the Navier–Stokes flow (where the matrix is block-symmetric/block-skew-symmetric); however, there has been very little investigation into the GMRES performance in incompressible nonlinear elasticity problems, where the nonlinearity of the incompressibility constraint means the matrix is not block-symmetric/block-skew-symmetric. In this short paper, we identify one feature of the problem formulation, which has a huge impact on unpreconditioned GMRES convergence. We explain that it is important to ensure that the matrices are perturbations of a block-skew-symmetric matrix rather than a perturbation of a block-symmetric matrix. This relates to the choice of sign before the incompressibility constraint integral in the weak formulation (with both choices being mathematically equivalent). The incorrect choice is shown to have a hugely detrimental effect on the total computation time.
- 1 February 2010
- Published by Wiley in Journal of Applied Mechanics
- Vol. 77 (3) , 034501
A Note on the Effect of the Choice of Weak Form on GMRES Convergence for Incompressible Nonlinear Elasticity Problems
The generalized minimal residual (GMRES) method is a common choice for solving the large nonsymmetric linear systems that arise when numerically computing solutions of incompressible nonlinear elasticity problems using the finite element method. Analytic results on the performance of GMRES are available on linear problems such as linear elasticity or Stokes’ flow (where the matrices in the corresponding linear systems are symmetric), or on the nonlinear problem of the Navier–Stokes flow (where the matrix is block-symmetric/block-skew-symmetric); however, there has been very little investigation into the GMRES performance in incompressible nonlinear elasticity problems, where the nonlinearity of the incompressibility constraint means the matrix is not block-symmetric/block-skew-symmetric. In this short paper, we identify one feature of the problem formulation, which has a huge impact on unpreconditioned GMRES convergence. We explain that it is important to ensure that the matrices are perturbations of a block-skew-symmetric matrix rather than a perturbation of a block-symmetric matrix. This relates to the choice of sign before the incompressibility constraint integral in the weak formulation (with both choices being mathematically equivalent). The incorrect choice is shown to have a hugely detrimental effect on the total computation time.
- 15 April 2009
- Published by IOP Publishing in Physical Biology
- Vol. 6 (3) , 036001
A computational study of discrete mechanical tissue models
A computational study of discrete 'cell-centre' approaches to modelling the evolution of a collection of cells is undertaken. The study focuses on the mechanical aspects of the tissue, in order to separate the passive mechanical response of the model from active effects such as cell-growth and cell division. Issues which arise when implementing these models are described, and a series of numerical mechanical experiments is performed. It is shown that discrete tissues modelled this way typically exhibit elastic-plastic behaviour under slow compression, and act as a brittle linear elastic solid under slow tension. Both overlapping spheres and Voronoi-tessellation-based models are examined, and the effect of different cell-cell interaction force laws on the bulk mechanical properties of the tissue is determined. This correspondence allows parameters in the cell-based model to be chosen to be compatible with bulk tissue measurements.
- 15 April 2009
- Published by IOP Publishing in Physical Biology
- Vol. 6 (3) , 036001
A computational study of discrete mechanical tissue models
A computational study of discrete 'cell-centre' approaches to modelling the evolution of a collection of cells is undertaken. The study focuses on the mechanical aspects of the tissue, in order to separate the passive mechanical response of the model from active effects such as cell-growth and cell division. Issues which arise when implementing these models are described, and a series of numerical mechanical experiments is performed. It is shown that discrete tissues modelled this way typically exhibit elastic-plastic behaviour under slow compression, and act as a brittle linear elastic solid under slow tension. Both overlapping spheres and Voronoi-tessellation-based models are examined, and the effect of different cell-cell interaction force laws on the bulk mechanical properties of the tissue is determined. This correspondence allows parameters in the cell-based model to be chosen to be compatible with bulk tissue measurements.
- Open Access
- 26 October 2008
- Published by Oxford University Press (OUP) in Quarterly Journal of Mechanics and Applied Mathematics
- Vol. 62 (1) , 67-88
Inverse membrane problems in elasticity
The inverse elasticity problem of determining the undeformed, deflated, configuration of a nonlinear elastic membrane, given the deformed configuration enclosing an incompressible fluid under known pressure, is considered. It is shown that, in practical cases, it is enough to determine only the undeformed metric tensor, and it is also shown how the two- and three-dimensional cases are fundamentally different. For the three-dimensional case, we set up and classify the partial differential equations to be solved, prove existence of an undeformed state given an undeformed metric and study the axisymmetric case in detail.
- 26 October 2008
- Published by Oxford University Press (OUP) in Quarterly Journal of Mechanics and Applied Mathematics
- Vol. 62 (1) , 67-88
Open AccessInverse membrane problems in elasticity
The inverse elasticity problem of determining the undeformed, deflated, configuration of a nonlinear elastic membrane, given the deformed configuration enclosing an incompressible fluid under known pressure, is considered. It is shown that, in practical cases, it is enough to determine only the undeformed metric tensor, and it is also shown how the two- and three-dimensional cases are fundamentally different. For the three-dimensional case, we set up and classify the partial differential equations to be solved, prove existence of an undeformed state given an undeformed metric and study the axisymmetric case in detail.
- 3 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (10) , 2471-2480
Predicting Tumor Location by Modeling the Deformation of the Breast
Breast cancer is one of the biggest killers in the western world, and early diagnosis is essential for improved prognosis. The shape of the breast varies hugely between the scenarios of magnetic resonance (MR) imaging (patient lies prone, breast hanging down under gravity), X-ray mammography (breast strongly compressed) and ultrasound or biopsy/surgery (patient lies supine), rendering image fusion an extremely difficult task. This paper is concerned with the use of the finite-element method and nonlinear elasticity to build a 3-D, patient-specific, anatomically accurate model of the breast. The model is constructed from MR images and can be deformed to simulate breast shape and predict tumor location during mammography or biopsy/surgery. Two extensions of the standard elasticity problem need to be solved: an inverse elasticity problem (arising from the fact that only a deformed, stressed, state is known initially), and the contact problem of modeling compression. The model is used for craniocaudal mediolateral oblique mammographic image matching, and a number of numerical experiments are performed.
- 3 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (10) , 2471-2480
Predicting Tumor Location by Modeling the Deformation of the Breast
Breast cancer is one of the biggest killers in the western world, and early diagnosis is essential for improved prognosis. The shape of the breast varies hugely between the scenarios of magnetic resonance (MR) imaging (patient lies prone, breast hanging down under gravity), X-ray mammography (breast strongly compressed) and ultrasound or biopsy/surgery (patient lies supine), rendering image fusion an extremely difficult task. This paper is concerned with the use of the finite-element method and nonlinear elasticity to build a 3-D, patient-specific, anatomically accurate model of the breast. The model is constructed from MR images and can be deformed to simulate breast shape and predict tumor location during mammography or biopsy/surgery. Two extensions of the standard elasticity problem need to be solved: an inverse elasticity problem (arising from the fact that only a deformed, stressed, state is known initially), and the contact problem of modeling compression. The model is used for craniocaudal mediolateral oblique mammographic image matching, and a number of numerical experiments are performed.