Eugene I. Palchikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eugene I. Palchikov has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
A. M. Ryabchun
Russian Academy of Sciences
3 shared publicationsA V Dolgikh
Lavrentyev Institute of Hydrodynamics SB RAS, 15, Lavrentyev prosp., Novosibirsk, 630090, Russia
2 shared publicationsA. V. Dolgikh
Lavrentyev Institute of Hydrodynamics, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
2 shared publicationsV V Klypin
Lavrentyev Institute of Hydrodynamics SB RAS, 15, Lavrentyev prosp., Novosibirsk, 630090, Russia
2 shared publicationsA M Ryabchun
Lavrentyev Institute of Hydrodynamics, Siberian Branch of the Russian Academy of Sciences, Russia
1 shared publicationA. D. Matrosov
Russian Academy of Sciences
1 shared publication
Latest Publications
- 1 August 2024
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 65 (4) , 602-608
SPIRAL HIGH-VOLTAGE PULSE GENERATOR WITH SPATIALLY SEPARATED INDUCTIVE AND CAPACITIVE PARTS
New modifications of spiral generators with meander striplines have been proposed in which the inductive and capacitive parts of the generator to be separated in space. The proposed modification allows separate regulation of the wave impedance of the double-bus spiral stripline and the generator winding inductance and capacitance. The characteristics of the generators have been studied experimentally, and theoretical models adequately describing the operation of these devices have been proposed. The developed generators can be used to produce pulsed X-ray apparatuses with explosive electron emission.
- 1 August 2024
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 65 (4) , 602-608
SPIRAL HIGH-VOLTAGE PULSE GENERATOR WITH SPATIALLY SEPARATED INDUCTIVE AND CAPACITIVE PARTS
New modifications of spiral generators with meander striplines have been proposed in which the inductive and capacitive parts of the generator to be separated in space. The proposed modification allows separate regulation of the wave impedance of the double-bus spiral stripline and the generator winding inductance and capacitance. The characteristics of the generators have been studied experimentally, and theoretical models adequately describing the operation of these devices have been proposed. The developed generators can be used to produce pulsed X-ray apparatuses with explosive electron emission.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (S1) , S265-S270
Application of LIGA Rasters for the Filtration of Scattered Radiation in Dental Radiography
An experimental study of the suppression of noise in the image of a dental visiograph, caused by scattered radiation in the X-ray range of the spectrum, is carried out. To suppress noise, a nickel raster fabricated using deep X-ray lithography is used. Placing the raster directly in front of the detector makes it possible to suppress the background caused by scattered radiation and increase the signal-to-noise ratio both in areas with low optical density and in areas with high optical density.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (S1) , S265-S270
Application of LIGA Rasters for the Filtration of Scattered Radiation in Dental Radiography
An experimental study of the suppression of noise in the image of a dental visiograph, caused by scattered radiation in the X-ray range of the spectrum, is carried out. To suppress noise, a nickel raster fabricated using deep X-ray lithography is used. Placing the raster directly in front of the detector makes it possible to suppress the background caused by scattered radiation and increase the signal-to-noise ratio both in areas with low optical density and in areas with high optical density.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 63 (4) , 566-573
COUPLED PENDULUMS AS A MECHANICAL MODEL OF THE TESLA TRANSFORMER
A resonant pulse transformer with shock excitation is compared with a system of coupled pendulums with different masses tuned to resonance. For the Tesla transformer and coupled pendulums, conditions for complete energy transfer during one-half of the beat cycle were obtained. The requirements for the system parameters and initial conditions necessary for complete transfer of energy in the case of two spring-coupled pendulums with different masses and of the same length were first determined theoretically and then verified experimentally. The dependence of the minimum time for complete transfer of energy from one pendulum to the other on the system parameters is obtained.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 63 (4) , 566-573
COUPLED PENDULUMS AS A MECHANICAL MODEL OF THE TESLA TRANSFORMER
A resonant pulse transformer with shock excitation is compared with a system of coupled pendulums with different masses tuned to resonance. For the Tesla transformer and coupled pendulums, conditions for complete energy transfer during one-half of the beat cycle were obtained. The requirements for the system parameters and initial conditions necessary for complete transfer of energy in the case of two spring-coupled pendulums with different masses and of the same length were first determined theoretically and then verified experimentally. The dependence of the minimum time for complete transfer of energy from one pendulum to the other on the system parameters is obtained.
- Open Access
- 1 November 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1128 (1) , 012117
Developing a new high-power flash X-ray apparatus with harmonized magnetic and electrical fields
This work presents the design and characteristics of the 700-kilovolt pulsed X-ray apparatus, based on a principally new electro-physical structure. The main idea of this structure is that Blumlein pulse-forming system (transmission line, PFL), the primary and secondary circuit inductances and the capacitance of the secondary circuit of the Tesla transformer, running in the first half-wave occupy the same volume in space and do not impede each other. This kind of circuit design and the packing density as related to the pulse output dose is unrivalled throughout the world. The dependences of dose on the forming line voltage, and the flash duration on the different apparatus construction are measured.
- 1 November 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1128 (1) , 012117
Open AccessDeveloping a new high-power flash X-ray apparatus with harmonized magnetic and electrical fields
This work presents the design and characteristics of the 700-kilovolt pulsed X-ray apparatus, based on a principally new electro-physical structure. The main idea of this structure is that Blumlein pulse-forming system (transmission line, PFL), the primary and secondary circuit inductances and the capacitance of the secondary circuit of the Tesla transformer, running in the first half-wave occupy the same volume in space and do not impede each other. This kind of circuit design and the packing density as related to the pulse output dose is unrivalled throughout the world. The dependences of dose on the forming line voltage, and the flash duration on the different apparatus construction are measured.
- Open Access
- 22 October 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 894 (1) , 012069
Pulse X-ray device for stereo imaging and few-projection tomography of explosive and fast processes
This paper describes the operation principles and design features of the device for single pulse X-raying of explosive and high-speed processes, developed on the basis of a Tesla transformer with lumped secondary capacitor bank. The circuit with the lumped capacitor bank allows transferring a greater amount of energy to the discharge circuit as compared with the Marks-surge generator for more effective operation with remote X-ray tubes connected by coaxial cables. The device equipped with multiple X-ray tubes provides simultaneous X-raying of extended or spaced objects, stereo imaging, or few-projection tomography.
- 22 October 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 894 (1) , 012069
Open AccessPulse X-ray device for stereo imaging and few-projection tomography of explosive and fast processes
This paper describes the operation principles and design features of the device for single pulse X-raying of explosive and high-speed processes, developed on the basis of a Tesla transformer with lumped secondary capacitor bank. The circuit with the lumped capacitor bank allows transferring a greater amount of energy to the discharge circuit as compared with the Marks-surge generator for more effective operation with remote X-ray tubes connected by coaxial cables. The device equipped with multiple X-ray tubes provides simultaneous X-raying of extended or spaced objects, stereo imaging, or few-projection tomography.
- 24 June 2016
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 61 (6) , 919-923
Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses
- 24 June 2016
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 61 (6) , 919-923
Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses
- 1 February 2013
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 77 (2) , 99-102
Spectrozonal digital X-ray diagnostics of explosive processes, based on imageplate detectors separated by an absorber
A method that uses overlapping calibration wedges, made from the materials being investigated and placed alongside an object, is proposed for calculating the individual thicknesses of two-component objects. On detectors separated by an absorber, images in two different ranges of X-ray hardness are recorded with a single flash. As a result, there is no need to know the spectrum of X-ray radiation source or the spectral characteristics of the radiographed objects or the detector in order to solve the inverse problem.
- 1 February 2013
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 77 (2) , 99-102
Spectrozonal digital X-ray diagnostics of explosive processes, based on imageplate detectors separated by an absorber
A method that uses overlapping calibration wedges, made from the materials being investigated and placed alongside an object, is proposed for calculating the individual thicknesses of two-component objects. On detectors separated by an absorber, images in two different ranges of X-ray hardness are recorded with a single flash. As a result, there is no need to know the spectrum of X-ray radiation source or the spectral characteristics of the radiographed objects or the detector in order to solve the inverse problem.
- 26 February 2012
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 57 (2) , 292-301
Modified spiral high-voltage generator for feeding a pulsed X-ray apparatus
New types of high-voltage pulse generators based on spiral striplines are studied experimentally. A new theoretical model of these generators is suggested. Some of the generators demonstrate a high (25–50%) efficiency. A functional breadboard of a pulsed X-ray apparatus based on a modified spiral generator is designed. The output parameters of the apparatus are sufficient to detect fast processes.
- 26 February 2012
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 57 (2) , 292-301
Modified spiral high-voltage generator for feeding a pulsed X-ray apparatus
New types of high-voltage pulse generators based on spiral striplines are studied experimentally. A new theoretical model of these generators is suggested. Some of the generators demonstrate a high (25–50%) efficiency. A functional breadboard of a pulsed X-ray apparatus based on a modified spiral generator is designed. The output parameters of the apparatus are sufficient to detect fast processes.
- 1 December 2007
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 52 (12) , 1597-1603
On the refinement of the theoretical model for a high-voltage spiral generator
The principle of operation of high-voltage pulse generators proposed by Fitch and Howell and independently by Belkin and Zharkova (1961) is analyzed. It is shown that the Fitch-Howell spiral generator is a particular case of the Belkin-Zharkova transformer. Models are suggested making it possible to describe the performance capabilities of the spiral generator for the case of nonideal geometry and operating conditions. A radically modified Ruhl-Herziger model improving the calculation accuracy by several times is presented. Comparison between calculation results and experimental data shows that the spiral generator is best described by the Tesla coil model when the number of turns is small and the inductance of the switch is high or by the modified Ruhl-Herziger model when the number of turns is large and the inductance of the switch is low.
- 1 December 2007
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 52 (12) , 1597-1603
On the refinement of the theoretical model for a high-voltage spiral generator
The principle of operation of high-voltage pulse generators proposed by Fitch and Howell and independently by Belkin and Zharkova (1961) is analyzed. It is shown that the Fitch-Howell spiral generator is a particular case of the Belkin-Zharkova transformer. Models are suggested making it possible to describe the performance capabilities of the spiral generator for the case of nonideal geometry and operating conditions. A radically modified Ruhl-Herziger model improving the calculation accuracy by several times is presented. Comparison between calculation results and experimental data shows that the spiral generator is best described by the Tesla coil model when the number of turns is small and the inductance of the switch is high or by the modified Ruhl-Herziger model when the number of turns is large and the inductance of the switch is low.
- 23 October 2006
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 23 (3-4) , 254-259
Mapping of Residual Oil and Water Saturation in Porous Media by Means of Digital X‐ray Laminography
- 23 October 2006
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 23 (3-4) , 254-259
Mapping of Residual Oil and Water Saturation in Porous Media by Means of Digital X‐ray Laminography