SESteven E. Eckert

Steven E. Eckert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Steven E. Eckert has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 18 February 2010
      • Vol. 24  (6) , 1113-8

    A retrospective study of the survival of smooth- and rough-surface dental implants.

    by Ayman A Balshe, Daniel A Assad, Steven E Eckert, Sreenivas Koka, Amy L Weaver

    To compare the time-dependent cumulative survival rates of smooth- and rough-surface dental implants. A retrospective chart review was conducted for two time periods: January 1, 1991, through December 31, 1996, during which smooth-surface implants were used, and January 1, 2001, through December 31, 2005, during which rough-surface implants were used. This study included all implants placed and restored in one institution during the two time frames. Data were collected relative to patient age, gender, implant diameter, implant length, and anatomic location of implants. To facilitate the comparison, implants from the first and second time periods were followed through mid-1998 and mid-2007, respectively. Associations of patient/implant characteristics with implant survival were evaluated using marginal Cox proportional hazards models (adjusted for age and gender) and summarized with hazard ratios and corresponding 95% confidence intervals. A total of 593 patients (322 women and 271 men; mean age, 51.3 +/- 18.5 years) received 2,182 smooth-surface implants between 1991 and 1996, while 905 patients (539 women and 366 men; mean age, 48.2 +/- 17.8 years) received 2,425 rough-surface implants between 2001 and 2005. At 5 years after implant placement, survival rates were 94.0% and 94.5%, respectively, for smooth- and rough-surface implants (difference not significant). Among the smooth implants, implant length <or= 10 mm and anatomic location were identified as significantly associated with implant failure. In contrast, among the rough implants, implant length <or= 10 mm and anatomic location were not identified as risk factors for implant failure. Based on this retrospective study of two groups of patients with different implant surfaces and more than 2,000 implants in each group, there was no significant difference in the survival rates of smooth- and rough-surface dental implants. Anatomic location and implant length <or= 10 mm were associated with failures of the smooth-surface implants only.


    • 4 November 2009
      • Vol. 24  (4) , 679-83

    Heat transfer to the implant-bone interface during preparation of a zirconia/alumina abutment.

    by Jung-Bo Huh, Steven E Eckert, Seok-Min Ko, Yong-Geun Choi

    Excessive heat at the implant-bone interface may compromise osseointegration. This study examined the heat generated at the implant surface during preparation of a zirconia/alumina abutment in vitro. Sixty zirconia/alumina abutments were randomized into 12 experimental groups. The abutments were connected to implants and embedded in an acrylic resin block in a 37 degrees C water bath. The abutments were reduced by 1 mm in height over a period of 1 minute with a high-speed handpiece and then polished for 30 seconds with a low-speed handpiece, both with and without an air/water coolant. Temperatures were recorded via thermocouples at the cervical, middle, and apical part of the implant surfaces. The Mann-Whitney rank-sum test was used to assess the statistical significance of the difference in temperature between the abutment/implant complexes altered with and without coolant. The 1-mm reduction with the high-speed handpiece without coolant resulted in a maximum temperature of 41.22 degrees C at the cervical portion of the implant. Three of four temperatures above 40 degrees C were observed at the cervical part of the implant following use of the high-speed handpiece without coolant. The temperature difference between "with coolant" and "without coolant" during both low-speed polishing and high-speed reduction was statistically significant at the cervical portion of the implant (P = .009). In contrast, the temperature difference between "with coolant" and "without coolant" during both low-speed polishing and high-speed reduction was not statistically significant at the middle and apical parts of the implant (P > .05). Preparation of a zirconia/alumina abutment caused an increase in temperature within the implant, but this temperature increase did not reach the critical levels described in the implant literature.


    • 17 February 2009
      • Vol. 23  (6) , 1117-22

    The effects of smoking on the survival of smooth- and rough-surface dental implants.

    by Ayman A Balshe, Steven E Eckert, Sreenivas Koka, Daniel A Assad, Amy L Weaver

    To compare the long-term survival rates of smooth- and rough-surface dental implants among smokers and nonsmokers. A retrospective chart review was conducted for 2 time periods: January 1, 1991, through December 31, 1996, during which smooth-surface implants were utilized, and January 1, 2001, through December 31, 2005, during which rough-surface implants were utilized. This review included all implants placed and restored in 1 institution during the 2 timeframes. Data were specifically collected relative to patient age, gender, smoking status, implant diameter, implant length, and anatomic location of implants. Implants from the first and second time periods were followed through mid-1998 and mid-2007, respectively. Associations of patient/implant characteristics with implant survival were evaluated using marginal Cox proportional hazards models (adjusted for age and gender) and summarized with hazard ratios (HR) and corresponding 95% confidence intervals (CI). A total of 593 patients (322 [54.3%] female; mean [SD] age, 51.3 [18.5] years) received 2,182 smooth-surface implants between 1991 and 1996, while 905 patients (539 [59.6%)] female; mean [SD] age, 48.2 [17.8] years) received 2,425 rough-surface implants between 2001 and 2005. Among the rough-surface implants, smoking was not identified as significantly associated with implant failure (HR = 0.8; 95% CI = 0.3 to 2.1; P = .68). In contrast, smoking was associated with implant failure among the group with smooth-surface implants (HR = 3.1; 95% CI = 1.6 to 5.9; P < .001). Implant anatomic location was not associated with implant survival among patients with rough-surface implants (P = .45) and among nonsmokers with smooth-surface implants (P = .17). However, anatomic location affected the implant survival among smokers with smooth-surface implants (P = .004). In particular, implant survival was the poorest for implants placed in the maxillary posterior areas of smokers. Based on this retrospective study, the following observations were made: Smoking was identified as a risk factor for implant failure of smooth-surface implants only; among the smokers who received smooth-surface implants, an association was identified between implant failure and location of the implant placement; no association was identified between implant failure and location among the smokers who received rough-surface implants.


    • 12 December 2007
      • Vol. 20  (6) , 606-8

    Clinical decision-making practices among a subset of North American prosthodontists.

    by Sreenivas Koka, Steven E Eckert, Yong-Geun Choi, Victor M Montori

    The aim of this study was to determine the decision-making practices of a subset of North American prosthodontists. A survey was administered to assess practitioner views regarding the relative importance of practitioner, patient, and patient family beliefs and preferences during treatment planning of the edentulous patient. In responses to abstract questions, practitioners appeared to endorse a blending of patient and practitioner beliefs and preferences when treatment planning. However, in response to a question proposing a simulated clinical scenario, practitioners indicated they placed a greater emphasis on their own beliefs when choosing a treatment option.


    • 19 August 2007
      • Vol. 20  (4) , 356

    Sequelae of partial edentulism.

    by Steven E Eckert


    • 28 October 2006
      • Vol. 21  (5) , 785-8

    Retrospective multicenter cohort study of the clinical performance of 2-stage implants in South Korean populations.

    by Seok-Min Ko, Jeong Keun Lee, Steven E Eckert, Yong-Geun Choi

    To evaluate long-term follow-up clinical performance of dental implants in use in South Korean populations. A retrospective multicenter cohort study design was used to collect long-term follow-up clinical data from dental records of 224 patients treated with 767 2-stage endosseous implants at Ajou University Medical Center and Bundang Jesaeng Hospital in South Korea from June 1996 through December 2003. Exposure variables such as gender, systemic disease, location, implant length, implant diameter, prosthesis type, opposing occlusion type, and date of implant placement were collected. Outcome variables such as date of implant failure were measured. Patient ages ranged from 17 to 71.7 years old (mean age, 45.6 years old). Implants were more frequently placed in men than in women (61% versus 39%, or 471 men versus 296 women). Systemic disease was described by 9% of the patients. All implants had hydroxyapatite-blasted surfaces. Most of the implants were 3.75 mm in diameter. Implant lengths 10 mm, 11.5 mm, 13 mm, and 15 mm were used most often. Differences of implant survival among different implant locations were observed. Implants were used to support fixed partial dentures for the majority of the restorations. The opposing dentition was natural teeth for about 50% of the implants. A survival rate of 97.9% (751 of 767) was observed after 4.5 years (mean, 1.95 +/- 1.2 years). Clinical performance of 2-stage dental implants demonstrated a high level of predictability. The results achieved with a South Korean population did not differ from results achieved with diverse ethnic groups.


    • 1 August 2006
      • Vol. 27  (8) , 432-4, 436

    Treatment planning the edentulous mandible.

    by Sreenivas Koka, Steven E Eckert

    • 11 April 2006
      • Vol. 19  (2) , 128-9

    The true goal of evidence-based dentistry.

    by Steven Eckert

    • 25 June 2005
      • Vol. 20  (3) , 406-15

    Comparison of dental implant systems: quality of clinical evidence and prediction of 5-year survival.

    by Steven E Eckert, Yong-Geun Choi, Andrés R Sánchez, Sreenivas Koka

    This literature review was conducted to evaluate the quality of current evidence of clinical performance provided by American Dental Association-certified dental implant manufacturers and manufacturers with strong market penetration in the United States. The study also compared the clinical performance of different dental implant systems. A letter was sent to 6 implant manufacturers requesting 10 references each that validated the manufacturer's implant system in a variety of clinical applications. References were reviewed and classified relative to strength of evidence. Data extraction was then performed. Comparisons of implant survival data from 5-year studies were made, and data were pooled to establish an overall 5-year survival rate with confidence intervals (CIs). A total of 69 references were provided by the 6 implant manufacturers (Astra Tech, Centerpulse, Dentsply/Friadent, Implant Innovations, Nobel Biocare, and Straumann) but only 59 articles were available for review. Of those references, most were level-4 (case series) or level-5 (expert opinion) articles. Five-year survival data were extracted from 17 articles demonstrating overlap of CIs from the weighted average of the pooled data from each specific manufacturer; substantial equivalence of all implant systems was demonstrated based upon survival alone at 5 years. When all data were pooled, the 5-year survival rate of 96% (CI: 93% to 98%) was observed for a total of 7,398 implants. No obvious differences in implant survival were observed when comparing implant systems. The evidence supporting implant therapy is generally derived from level-4 case series rather than higher-level cohort or controlled clinical trials. Articles that directly compared different implant systems were not found. Five-year implant survival rates easily exceeded the minimums recommended by the American Dental Association certification program. (More than 50 references.)