JSJennifer H. Siggers

Jennifer H. Siggers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jennifer H. Siggers has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Flow in the anterior chamber of the eye with an implanted iris-fixated artificial lens

    by Jennifer H Tweedy, Jan O Pralits, Rodolfo Repetto, Paolo Soleri

    Flow in the aqueous humour that fills the anterior chamber of the eye occurs in response to the production and drainage of the aqueous humour, and also due to buoyancy effects produced by thermal gradients. Phakic intraocular lenses are manufactured lenses that are surgically inserted in the eyes of patients to correct refractive errors. Their presence has a dramatic effect on the circulation of the aqueous humour, resulting a very different flow in the anterior chamber, the effects of which have not been extensively investigated. In this article we use a simplified mathematical model to analyse the flow, in order to assess the effect of the implanted lens on the pressure drop required to drive the flow and also on the wall shear stress experienced by the corneal endothelial cells and the cells of the iris. A high pressure drop could result in an increased risk of glaucoma, whilst raised shear stress on the cornea could result in a reduction in the density of endothelial cells there, and on the iris it could result in the detachment of pigment cells, which block the outflow of the eye, also leading to glaucoma. Our results confirm those of previous fully numerical studies, and show that, although the presence of the lens causes significant differences in the flow topology and direction, the typical magnitudes of the shear stress are not significantly changed from the natural case. Our semi-analytical solution allows us to perform a thorough study of the dependence of the results on the controlling parameters and also to understand the basic physical mechanisms underlying flow characteristics.


  • Microcirculation of Blood and Interstitial Fluid in a Poroelastic Model of the Liver

    by Maryam Argungu, Jennifer H. Tweedy

    Cirrhosis is a life-threatening condition that represents a leading cause of death in the western world. In this condition the structure of the liver tissue is altered by the development of fibrosis, which means it becomes stiffer and its permeability to blood and interstitial flow within the tissue that are vital to its function are reduced. We develop a new mathematical model based on those, which we use to investigate the changes in liver volume, blood flow and lymphatic uptake, which measures interstitial flow, that occur as the tissue becomes progressively stiffer. Our results suggest that the typical changes that develop during cirrhosis have a significant effect on the permeability properties, highlighting the seriousness of this condition.

  • Phakic Iris-Fixated Intraocular Lens Placement in the Anterior Chamber: Effects on Aqueous Flow

    by Rodolfo Repetto, Jan O. Pralits, Jennifer H. Siggers, Paolo Soleri

    Purpose.: Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. Methods.: We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. Results.: We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. Conclusions.: We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.


  • Open Access

    Mathematical model of blood and interstitial flow and lymph production in the liver

    by Jennifer H. Siggers, Kritsada Leungchavaphongse, Chong Hang Ho, Rodolfo Repetto

    We present a mathematical model of blood and interstitial flow in the liver. The liver is treated as a lattice of hexagonal ‘classic’ lobules, which are assumed to be long enough that end effects may be neglected and a two-dimensional problem considered. Since sinusoids and lymphatic vessels are numerous and small compared to the lobule, we use a homogenized approach, describing the sinusoidal and interstitial spaces as porous media. We model plasma filtration from sinusoids to the interstitium, lymph uptake by lymphatic ducts, and lymph outflow from the liver surface. Our results show that the effect of the liver surface only penetrates a depth of a few lobules’ thickness into the tissue. Thus, we separately consider a single lobule lying sufficiently far from all external boundaries that we may regard it as being in an infinite lattice, and also a model of the region near the liver surface. The model predicts that slightly more lymph is produced by interstitial fluid flowing through the liver surface than that taken up by the lymphatic vessels in the liver and that the non-peritonealized region of the surface of the liver results in the total lymph production (uptake by lymphatics plus fluid crossing surface) being about 5 % more than if the entire surface were covered by the Glisson–peritoneal membrane. Estimates of lymph outflow through the surface of the liver are in good agreement with experimental data. We also study the effect of non-physiological values of the controlling parameters, particularly focusing on the conditions of portal hypertension and ascites. To our knowledge, this is the first attempt to model lymph production in the liver. The model provides clinically relevant information about lymph outflow pathways and predicts the systemic response to pathological variations.


  • Mathematical model of flow through the patent ductus arteriosus

    by Adriana Setchi, A. Jonathan Mestel, Jennifer H. Siggers, Kim H. Parker, Ming Wang Tan, Kangwen Wong


  • Mathematical Modeling of the Circulation in the Liver Lobule

    by Andrea Bonfiglio, Kritsada Leungchavaphongse, Rodolfo Repetto, Jennifer H. Siggers

    In this paper, we develop a mathematical model of blood circulation in the liver lobule. We aim to find the pressure and flux distributions within a liver lobule. We also investigate the effects of changes in pressure that occur following a resection of part of the liver, which often leads to high pressure in the portal vein. The liver can be divided into functional units called lobules. Each lobule has a hexagonal cross-section, and we assume that its longitudinal extent is large compared with its width. We consider an infinite lattice of identical lobules and study the two-dimensional flow in the hexagonal cross-sections. We model the sinusoidal space as a porous medium, with blood entering from the portal tracts (located at each of the vertices of the cross-section of the lobule) and exiting via the centrilobular vein (located in the center of the cross-section). We first develop and solve an idealized mathematical model, treating the porous medium as rigid and isotropic and blood as a Newtonian fluid. The pressure drop across the lobule and the flux of blood through the lobule are proportional to one another. In spite of its simplicity, the model gives insight into the real pressure and velocity distribution in the lobule. We then consider three modifications of the model that are designed to make it more realistic. In the first modification, we account for the fact that the sinusoids tend to be preferentially aligned in the direction of the centrilobular vein by considering an anisotropic porous medium. In the second, we account more accurately for the true behavior of the blood by using a shear-thinning model. We show that both these modifications have a small quantitative effect on the behavior but no qualitative effect. The motivation for the final modification is to understand what happens either after a partial resection of the liver or after an implantation of a liver of small size. In these cases, the pressure is observed to rise significantly, which could cause deformation of the tissue. We show that including the effects of tissue compliance in the model means that the total blood flow increases more than linearly as the pressure rises.


  • Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry

    by R. Repetto, J. H. Siggers, A. Stocchino

    Saccadic eye rotations induce a flow in the vitreous humor of the eye. Any such flow is likely to have a significant influence on the dispersion of drugs injected into the vitreous chamber. The shape of this chamber deviates from a perfect sphere by up to 10–20% of the radius, which is predominantly due to an indentation caused by the lens. In this paper we investigate theoretically the effect of the domain shape upon the flow field generated by saccades by considering an idealized model. The posterior chamber geometry is assumed to be a sphere with a small indentation, undergoing prescribed small-amplitude sinusoidal torsional oscillations, and, as an initial step towards understanding the problem, we treat the vitreous humor as a Newtonian fluid filling the chamber. The latter assumption applies best in the case of a liquefied vitreous or a tamponade fluid introduced in the vitreous chamber after vitrectomy. We find the flow field in terms of vector spherical harmonics, focusing on the deviation from the flow that would be obtained in a perfect sphere. The flow induced by the departure of the domain geometry from the spherical shape has an oscillating component at leading order and a smaller-amplitude steady streaming flow. The oscillating component includes a circulation cell formed every half-period, which migrates from the indentation towards the center of the domain where it disappears. The steady component has two counter-rotating circulations in the anterior part of the domain. These findings are in good qualitative agreement with the experimental results of Stocchino et al. (Phys Med Biol 52:2021–2034, 2007). Our results predict a significant reduction in the expected time for drug dispersal across the eye compared with the situation in which there is no fluid flow present.


  • Flow dynamics in a stented ureter

    by Jennifer H. Siggers, Sarah Waters, Jonathan Wattis, Linda Cummings

    Vesicorenal reflux is a major side effect associated with ureteric stent placement. In a stented upper urinary tract when the bladder pressure rises, such as during bladder spasms (due to irritation caused by the stent) or voiding of the bladder, it drives urine reflux up the ureter, which, in turn, may be a contributory factor for infections in the renal pelvis. We develop a mathematical model to examine urine flow in a stented ureter, assuming that it remains axisymmetric and treating the wall as a non-linear elastic membrane. The stent is modelled as a rigid, permeable, hollow, circular cylinder lying coaxially inside the ureter. The renal pelvis is treated as an elastic bag, whose volume increases in response to an increased internal pressure. Fluid enters the renal pelvis from the kidney with a prescribed flux. The stent, ureter and renal pelvis are filled with urine, and the bladder pressure is prescribed. We use the model to calculate the total volume of reflux generated during rises in bladder pressure and investigate how it is affected by the stent and ureter properties.