ANAmr A. Nassr

Amr A. Nassr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amr A. Nassr has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental Performance of Steel Beams under Blast Loading

    by Amr A. Nassr, A. Ghani Razaqpur, Michael J. Tait, Manuel Campidelli, Simon Foo

    In this study, the dynamic response of typical wide-flange steel beams was experimentally evaluated under blast loading. A total of 13 beams were field tested using live explosives, where the charge size ranged from 50 to 250 kg of ammonium nitrate-fuel oil mixture, and the ground stand-off distance was from 7.0 to 10.3 m. Blast wave characteristics, including incident and reflected pressures, were recorded. In addition, time-dependent displacements, accelerations, and strains at different locations along the steel members were measured, and the postblast damage and mode of failure of the test specimens were observed. The blast load characteristics were compared with those obtained using the Technical Manual UFC 3-340-02 results. The displacement response results were used to validate the results obtained from a nonlinear dynamic analysis based on a single degree-of-freedom (SDOF) model. Results showed that the UFC 3-340-02 pressure predictions compare reasonably well with the measured pressure in the positive phase in terms of both the peak pressure and overall time variations. The SDOF model predicted the maximum displacements of beams in the elastic range reasonably well, but it overestimated them in the plastic range.


  • Detection of Ungrouted Cells in Concrete Masonry Constructions Using a Dielectric Variation Approach

    by Wael W. El-Dakhakhni, Amr A. Nassr, Marwan T. Shedid

    In this study, a new technique for detecting ungrouted cells in concrete block masonry constructions was developed. The concept, based on detecting the local dielectric permittivity variations, was employed to design coplanar capacitance sensors with high sensitivities to detect such construction defects. An analytical model and finite element simulations were used to assess the influence of the sensor geometrical parameters on the sensor signals and to optimize the sensor design. To experimentally verify the model, the dielectric properties of various materials involved in concrete masonry walls were measured. In addition, a masonry wall containing predetermined grouted and ungrouted cells was constructed and inspected using the developed sensors in a laboratory setting. Moreover, different capacitance sensors were designed and compared with respect to their sensitivity, signal-to-noise ratio, and coefficient of variation of the inspected measurements. Excellent agreements were found between the experimental capacitance signal response parameters and those predicted by the analytical and finite element models. The proposed sensor design, coupled with a commercially available portable capacitance meter, would facilitate employing this technique in the field for rapid inspection of masonry structures without the need for sophisticated data analyses usually required by other more expensive and time consuming methods.


  • Damage Detection of FRP-Strengthened Concrete Structures Using Capacitance Measurements

    by Amr A. Nassr, Wael W. El-Dakhakhni

    In this study, a new concept for detecting air voids, water intrusion, and glue infiltration damages in fiber-reinforced polymers (FRPs)-strengthened concrete structures was developed. The concept, based on detecting the local dielectric permittivity variations, was employed to design coplanar capacitance sensors (CCSs) to detect such defects. An analytical model was used to introduce the sensor operation theory and analyze the influence of different sensor parameters on the output signals and to optimize sensor design. Two dimensional finite element (FE) simulations were performed to assess the validity of the analytical results and to evaluate other sensor design-related parameters. To experimentally verify the FE model, dielectric properties of various materials involved in FRP-strengthened concrete systems were measured. In addition, two concrete specimens strengthened with FRP laminates and containing preinduced defects were constructed and inspected in a laboratory setting. Good agreement was found ...


  • Biodegradation and Debonding Detection of Composite-wrapped Wood Structures

    by Amr A. Nassr, Wael W. El-Dakhakhni, Wael H. Ahmed

    In this article, a methodology is presented for detecting biodegradation and debonding damage in composite-wrapped wood structures using a coplanar capacitance sensor. The presence of damage in the composite/wood interface alters the dielectric characteristics, causing a variation in the measured capacitance by the sensor. The theoretical background employed in developing the proposed capacitance technique is highlighted. A glass fiber reinforced polymers (GFRP)-wrapped wood column, containing pre-induced defects to simulate biodegradation damage and debonding of the GFRP at the composite/wood interface, was constructed and inspected in a laboratory setting. A coplanar capacitance sensor was designed and used for the inspection of simulated defects of different severity. The capacitance signals were measured and the sensor sensitivity was evaluated for each defect type. The proposed technique can be used for rapid damage screening, scheduled or random inspection, or as permanent sensor network within the composite/wood system as a structural health monitoring technique.