SLSeunghyun Lee

Seunghyun Lee

*This is an algorithmically generated author record based on publicly available information.

Seunghyun Lee has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Study of the Rainwater Pumping Station Operation Plan to Reduce River Water Level

    by Eungseok Kim, Seunghyun Lee

    Urban flood damage is caused by various and complex effects such as inland flood and external water flooding, so research on this is necessary. This study presented a rainwater pumping station operation technique that can suppress the rise in water levels in discharge rivers based on rainfall and pump operation scenarios in order to reduce inland water flooding and simultaneously consider external water levels. The research method used genetic algorithm (GA) optimization techniques to calculate the optimal operating level for each pump, and based on this, an operating scenario was created to minimize pump operation. In addition, after constructing a rainfall scenario based on the probability rainfall in Seoul, an optimal pump operation technique that can reduce the external water level while minimizing the inundation of domestic water was proposed. The results of the study showed that as the rainfall intensity increases, the flooding increases and the peak depth of the runoff increases. In addition, as the pumping scenario changes from 1 to 11, the number of pumping operations decreases, which reduces the drainage volume of the pumps, which increases the flooding.


  • Open Access

    Proposed Technique for Estimating Rainwater Storage Tank Locations Using Vulnerability Analysis of Critical Flooding Nodes

    by Eungseok Kim, Seunghyun Lee

    Even if a pumping station, which is a representative structural flood defense facility, operates optimally, flooding occurs at certain nodes in the drainage area. In other words, even if rainwater pumping stations and rainwater storage tank, which are structural flood defense measures, operate at maximum, it is necessary to review areas where overflow occurs. Therefore, in areas where it is impossible to protect against inland flooding using structural flood defense measures alone, new flood defense measures are required. In this study, based on previous research on rainwater pumping station operation techniques to reduce critical flooding, the Daelim 3 region was divided into 45 basic areas and vulnerability analysis techniques were applied to select the location of rainwater storage tank for effective flood defense. A possible technique is presented in this paper. As a result of the study, sub-region 1 had the highest impact index value, so installing a rainwater storage tank was calculated to be more effective in preventing floods than installing a rainwater storage tank in other sub-regions. The priority-estimation technique for flood defense facilities presented in this study can be effective in establishing plans for flood control structures other than rainwater storage tank.

  • Open Access

    Comparison of Assessments of Urban Areas Using the Flood Vulnerability and Potential Flood Damage Methods

    by Eungseok Kim, Seunghyun Lee

    Recently, urban flood damage has rapidly increased due to climate change, rapid urbanization, and frequent guerrilla heavy rains. Therefore, a quantitative flood damage analysis technique is required for effective policy regarding flooding in urban areas. In this study, the flood vulnerability and potential flood damage (PFD) methods, which are representative methods for analyzing the degree of flood damage in urban areas, were applied. In addition, the results of each analysis method were compared and analyzed using the flood prevention capacity-damage (PCD) matrix technique, which intuitively shows that even if many existing flood protection facilities are built, flood damage can be large when there is insufficient management or heavy rainfall exceeding the design rainfall occurs. The two existing flood damage techniques estimated Seocho-gu to have low flood vulnerability due to high financial independence and many flood damage protection facilities. However, application of the PCD matrix resulted in classifying Seocho-gu as highly vulnerable to flooding. These conflicting results thus demonstrate that a more detailed review and analysis are necessary when establishing a flood protection policy.


  • Open Access

    Analysis of Changes in River Water Quality Due to Weir Installation

    by Eungseok Kim, Seunghyun Lee

    There has been an increase in the amount of pollutants such as biochemical water and factory wastewater discharged from urban areas as a result of urbanization and industrialization. Therefore, research on securing water resources and improving water quality in rivers around cities is being actively conducted. This study analyzed the pattern of change of water quality due to the installation of overflow type weirs among the hand structures in the existing river. The target watershed was performed at Gilancheon, located in Andong-si, Gyeongsangbuk-do. The flow coefficient was calculated by analyzing the flow velocity and water level according to weir installation using the HEC-RAS. Afterwards, the QUALKO model was built, and the water quality analysis according to weir installation was performed by applying the flow coefficient calculated using HEC-RAS. As a result of the analysis, the flow rate was found to have decreased, and a stagnation section occurred due to the influence of weir installation, resulting in an increase in Chl-a. Due to the increase of Chl-a, BOD increased by 29%-32%, and T-N and T-P, which are nutrients for Chl-a, decreased. Therefore, an increase in Chl-a concentration due to weir installation can cause eutrophication due to the growth of green algae in the river, and it is believed that it can greatly affect the deterioration of water quality. Furthermore, it is considered that it will be able to help predict changes in water quality for the installation and operation of weirs in the future.