Ambroos Stals
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ambroos Stals has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Els Van Coillie
Flemish Government, Institute for Agricultural and Fisheries Research, Technology and Food Science Unit, Brusselsesteenweg 370, 9090 Melle, Belgium
6 shared publicationsMieke Uyttendaele
Ghent University, Faculty of Bioscience Engineering, Department of Food Safety and Food Quality, Laboratory of Food Microbiology and Food Preservation, Coupure links 653, 9000 Ghent, Belgium
6 shared publicationsLeen Baert
3 shared publicationsAnn De Keuckelaere
Ghent University, Faculty of Bioscience Engineering, Department of Food Safety and Food Quality, Laboratory of Food Microbiology and Food Preservation, Coupure links 653, 9000 Ghent, Belgium
1 shared publication- Leen Baert
Ghent University, Faculty of Bioscience Engineering, Department of Food Safety and Food Quality, Laboratory of Food Microbiology and Food Preservation, Coupure links 653, 9000 Ghent, Belgium
1 shared publication Vicky Jasson
1 shared publication
Latest Publications
- 1 September 2013
- Published by Oxford University Press (OUP)
- Vol. 96 (5) , 998-1005
The Need for Harmonization in Detection of Human Noroviruses in Food
Noroviruses (NoV) have been recognized worldwide as a leading cause of foodborne gastroenteritis over the last decade. A broad range of foods—shellfish, fresh produce, and ready-to-eat/catered foods—has been implicated in NoV foodborne outbreaks. The recognition of NoV as an important food pathogen has been aided by the development of sensitive molecular methods for detection of the NoV genome. However, despite advances, NoV detection is still hampered by several limitations. First, NoV detection can often only be implemented by expert laboratories due to the complexity of the virus extraction step, which in most protocols is cumbersome and labor-intensive. Moreover, a very wide selection of automated methods for virus extraction from foods is available, so selection of an adequate method is not straightforward. On the other hand, automated systems have been made available or the RNA purification and real-time RT-PCR (RT-qPCR) is considered the gold standard for detection of NoV. Second, correct interpretation of real-time PCR results is often difficult. From a technical point of view, the interpretation of the often nonsigmoidal amplification curves remains difficult, even for experts. From a food safety perspective, interpretation of very high Cq (or Ct) values—and thus, of low viral genomic copy numbers—is not straightforward, as RT-(q)PCR merely detects the presence of viral genomic material that is not necessarily linked to the presence of infectious viral particles. Despite efforts, both limitations have not completely resolved thus far. Harmonization may be a first step to comprehend and deal with these limitations. The current review provides an overview of a number of validated methods that have been published by food safety and other authorities.
- 1 September 2013
- Published by Oxford University Press (OUP)
- Vol. 96 (5) , 998-1005
The Need for Harmonization in Detection of Human Noroviruses in Food
Noroviruses (NoV) have been recognized worldwide as a leading cause of foodborne gastroenteritis over the last decade. A broad range of foods—shellfish, fresh produce, and ready-to-eat/catered foods—has been implicated in NoV foodborne outbreaks. The recognition of NoV as an important food pathogen has been aided by the development of sensitive molecular methods for detection of the NoV genome. However, despite advances, NoV detection is still hampered by several limitations. First, NoV detection can often only be implemented by expert laboratories due to the complexity of the virus extraction step, which in most protocols is cumbersome and labor-intensive. Moreover, a very wide selection of automated methods for virus extraction from foods is available, so selection of an adequate method is not straightforward. On the other hand, automated systems have been made available or the RNA purification and real-time RT-PCR (RT-qPCR) is considered the gold standard for detection of NoV. Second, correct interpretation of real-time PCR results is often difficult. From a technical point of view, the interpretation of the often nonsigmoidal amplification curves remains difficult, even for experts. From a food safety perspective, interpretation of very high Cq (or Ct) values—and thus, of low viral genomic copy numbers—is not straightforward, as RT-(q)PCR merely detects the presence of viral genomic material that is not necessarily linked to the presence of infectious viral particles. Despite efforts, both limitations have not completely resolved thus far. Harmonization may be a first step to comprehend and deal with these limitations. The current review provides an overview of a number of validated methods that have been published by food safety and other authorities.
- 1 July 2013
- Published by Elsevier in Journal of Food Protection
- Vol. 76 (7) , 1202-1209
Norovirus Transfer between Foods and Food Contact Materials
Human infective noroviruses (NoVs) are a worldwide leading cause of foodborne illness and are frequently spread via infected food handlers preparing and manipulating food products such as deli sandwiches. The objective of the current study was to determine the efficiencies whereby NoV could be transferred between surfaces associated with the preparation of manually prepared foods such as deli sandwiches. Nonfood surfaces included gloves and stainless steel discs, and boiled ham, lettuce, and a sandwich bun were the ingredients of the deli sandwich. Both NoV GII.4 and the murine NoV 1 (MNV-1, a cultivable human NoV surrogate) were included in the presented study. Transfer of NoV GII.4 and MNV-1 between surfaces was performed by pressing an inoculated donor surface against an acceptor surface. To evaluate the effect of subsequent contact, donor surfaces were pressed a second time to an identical acceptor surface. Subsequently, NoV GII.4 and MNV-1 were detected using real-time reverse transcription PCR assays and plaque assays, respectively. Transfer of both viruses from gloves to stainless steel was inefficient, and virus transfer from food products to stainless steel occurred with more variability for NoV GII.4 than for MNV-1. Virus transfer from the stainless steel discs to the gloves was substantially more efficient than from the gloves to the stainless steel. NoV GII.4 and MNV-1 transfer from food products to the gloves occurred with varying efficiencies, although this variation was more evident for NoV GII.4. The MNV-1 inoculum was significantly less efficiently transferred to the acceptor surface at the second contact, which was not the case for NoV GII.4. The obtained transfer efficiency data may provide insights into the transfer of NoV during preparation of foods and can be included in risk assessment models describing the transmission of NoVs in this context.
- 1 July 2013
- Published by Elsevier in Journal of Food Protection
- Vol. 76 (7) , 1202-1209
Norovirus Transfer between Foods and Food Contact Materials
Human infective noroviruses (NoVs) are a worldwide leading cause of foodborne illness and are frequently spread via infected food handlers preparing and manipulating food products such as deli sandwiches. The objective of the current study was to determine the efficiencies whereby NoV could be transferred between surfaces associated with the preparation of manually prepared foods such as deli sandwiches. Nonfood surfaces included gloves and stainless steel discs, and boiled ham, lettuce, and a sandwich bun were the ingredients of the deli sandwich. Both NoV GII.4 and the murine NoV 1 (MNV-1, a cultivable human NoV surrogate) were included in the presented study. Transfer of NoV GII.4 and MNV-1 between surfaces was performed by pressing an inoculated donor surface against an acceptor surface. To evaluate the effect of subsequent contact, donor surfaces were pressed a second time to an identical acceptor surface. Subsequently, NoV GII.4 and MNV-1 were detected using real-time reverse transcription PCR assays and plaque assays, respectively. Transfer of both viruses from gloves to stainless steel was inefficient, and virus transfer from food products to stainless steel occurred with more variability for NoV GII.4 than for MNV-1. Virus transfer from the stainless steel discs to the gloves was substantially more efficient than from the gloves to the stainless steel. NoV GII.4 and MNV-1 transfer from food products to the gloves occurred with varying efficiencies, although this variation was more evident for NoV GII.4. The MNV-1 inoculum was significantly less efficiently transferred to the acceptor surface at the second contact, which was not the case for NoV GII.4. The obtained transfer efficiency data may provide insights into the transfer of NoV during preparation of foods and can be included in risk assessment models describing the transmission of NoVs in this context.
- 1 February 2013
- Published by Elsevier in Current Opinion in Virology
- Vol. 3 (1) , 69-73
Viral genes everywhere: public health implications of PCR-based testing of foods
- 1 February 2013
- Published by Elsevier in Current Opinion in Virology
- Vol. 3 (1) , 69-73
Viral genes everywhere: public health implications of PCR-based testing of foods
- 1 March 2011
- Published by Elsevier in Journal of Food Protection
- Vol. 74 (3) , 425-431
Screening of Fruit Products for Norovirus and the Difficulty of Interpreting Positive PCR Results
Despite recent norovirus (NoV) outbreaks related to consumption of fruit products, little is known regarding the NoV load on these foods. Therefore, 75 fruit products were screened for NoV presence by using an evaluated in-house NoV detection methodology consisting of a NoV extraction method and a reverse transcription quantitative PCR assay. Additionally, the fruit samples were screened for bacterial pathogens and bacterial hygiene indicators. Results of the NoV screening showed that 18 of 75 samples tested positive for GI and/or GII NoV despite a good bacteriological quality. The recovery of murine norovirus 1 virus particles acting as process control was successful in 31 of 75 samples with a mean recovery efficiency of 11.32% ± 6.08%. The level of detected NoV genomic copies ranged between 2.5 and 5.0 log per 10 g. NoV GI and/or GII were found in 4 of 10, 7 of 30, 6 of 20, and 1 of 15 of the tested raspberries, cherry tomatoes, strawberries, and fruit salad samples, respectively. However, confirmation of the positive quantitative PCR results by sequencing genotyping regions in the NoV genome was not possible. Due to the nature of the method used (reverse transcription quantitative PCR) for detection of genomic material, no differentiation was possible between infectious and noninfectious viral particles. No NoV outbreaks related to the tested fruit product types were reported during the screening period, which hampers a conclusion as to whether these unexpected high numbers of NoV-positive results should be perceived as a public health threat. These results, however, may indicate a prior NoV contamination of the tested food samples throughout the fresh produce chain.
- 1 March 2011
- Published by Elsevier in Journal of Food Protection
- Vol. 74 (3) , 425-431
Screening of Fruit Products for Norovirus and the Difficulty of Interpreting Positive PCR Results
Despite recent norovirus (NoV) outbreaks related to consumption of fruit products, little is known regarding the NoV load on these foods. Therefore, 75 fruit products were screened for NoV presence by using an evaluated in-house NoV detection methodology consisting of a NoV extraction method and a reverse transcription quantitative PCR assay. Additionally, the fruit samples were screened for bacterial pathogens and bacterial hygiene indicators. Results of the NoV screening showed that 18 of 75 samples tested positive for GI and/or GII NoV despite a good bacteriological quality. The recovery of murine norovirus 1 virus particles acting as process control was successful in 31 of 75 samples with a mean recovery efficiency of 11.32% ± 6.08%. The level of detected NoV genomic copies ranged between 2.5 and 5.0 log per 10 g. NoV GI and/or GII were found in 4 of 10, 7 of 30, 6 of 20, and 1 of 15 of the tested raspberries, cherry tomatoes, strawberries, and fruit salad samples, respectively. However, confirmation of the positive quantitative PCR results by sequencing genotyping regions in the NoV genome was not possible. Due to the nature of the method used (reverse transcription quantitative PCR) for detection of genomic material, no differentiation was possible between infectious and noninfectious viral particles. No NoV outbreaks related to the tested fruit product types were reported during the screening period, which hampers a conclusion as to whether these unexpected high numbers of NoV-positive results should be perceived as a public health threat. These results, however, may indicate a prior NoV contamination of the tested food samples throughout the fresh produce chain.
- 28 February 2011
- Published by Elsevier in International Journal of Food Microbiology
- Vol. 145 (2-3) , 420-425
Evaluation of a norovirus detection methodology for ready-to-eat foods
- 28 February 2011
- Published by Elsevier in International Journal of Food Microbiology
- Vol. 145 (2-3) , 420-425
Evaluation of a norovirus detection methodology for ready-to-eat foods
- 28 February 2011
- Published by Elsevier in Food Microbiology
- Vol. 28 (1) , 52-58
Evaluation of a norovirus detection methodology for soft red fruits
- 28 February 2011
- Published by Elsevier in Food Microbiology
- Vol. 28 (1) , 52-58
Evaluation of a norovirus detection methodology for soft red fruits