Ka Yin Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ka Yin Chan has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Pauline Cho
School of Optometry, The Hong Kong Polytechnic University, Hong Kong SAR, China
10 shared publications Sin Wan Cheung
School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong
7 shared publicationsMaureen Boost
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region
2 shared publicationsAilsa Chui-Ying Yuen
Research Centre for Chinese Medicine Innovation, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
1 shared publication- Alex Hui
University of Waterloo
1 shared publication Allen My. Cheong
Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
1 shared publication
Latest Publications
- 25 October 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (2) , 156-170
A review of using Traditional Chinese Medicine in the management of glaucoma and cataract
Traditional Chinese Medicine has a long history in ophthalmology in China. Over 250 kinds of Traditional Chinese Medicine have been recorded in ancient books for the management of eye diseases, which may provide an alternative or supplement to current ocular therapies. However, the core holistic philosophy of Traditional Chinese Medicine that makes it attractive can also hinder its understanding from a scientific perspective - in particular, determining true cause and effect. This review focused on how Traditional Chinese Medicine could be applied to two prevalent ocular diseases, glaucoma, and cataract. The literature on preclinical and clinical studies in both English and Chinese on the use of Traditional Chinese Medicine to treat these two diseases was reviewed. The pharmacological effects, safety profile, and drug-herb interaction of selected herbal formulas were also investigated. Finally, key considerations for conducting future Traditional Chinese Medicine studies are discussed.
- 25 October 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (2) , 156-170
A review of using Traditional Chinese Medicine in the management of glaucoma and cataract
Traditional Chinese Medicine has a long history in ophthalmology in China. Over 250 kinds of Traditional Chinese Medicine have been recorded in ancient books for the management of eye diseases, which may provide an alternative or supplement to current ocular therapies. However, the core holistic philosophy of Traditional Chinese Medicine that makes it attractive can also hinder its understanding from a scientific perspective - in particular, determining true cause and effect. This review focused on how Traditional Chinese Medicine could be applied to two prevalent ocular diseases, glaucoma, and cataract. The literature on preclinical and clinical studies in both English and Chinese on the use of Traditional Chinese Medicine to treat these two diseases was reviewed. The pharmacological effects, safety profile, and drug-herb interaction of selected herbal formulas were also investigated. Finally, key considerations for conducting future Traditional Chinese Medicine studies are discussed.
- 17 October 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (6) , 603-608
YouTube as a learning source for contact lens insertion and removal
Contact lens neophytes often learn about contact lens insertion and removal through YouTube videos of unknown quality. This study evaluates the quality of soft contact lens insertion and removal videos on YouTube. A search for the keywords 'Contact lens insertion', 'Contact lens removal', 'Put in contact lens', and 'Take off contact lens' was performed on YouTube. The first 50 videos for each keyword were evaluated. The number of views, source of the publisher, days since upload, and video quality were scored based on the content in the videos. The maximum score of insertion and removal videos were 7 and 5 respectively. The videos were classified into three groups by publisher category: videos published by eye care professionals, companies and YouTubers. Only 45 contact lens insertion and 44 removal videos met the inclusion criteria and were analysed. Insertion and removal videos published by YouTubers had the highest view and view rate. However, their quality scores were significantly lower than videos published by eye care professionals and companies. Videos uploaded by companies had the highest scores (insertion: 5.00 ± 1.10; removal: 3.25 ± 0.75). The mean scores of insertion and removal videos published by YouTubers were 1.65 ± 0.93 and 1.00 ± 0.89, respectively, while the insertion and removal videos uploaded by eye care professionals scored 3.58 ± 2.07 and 2.75 ± 1.53, respectively. There was also a negative correlation between the quality scores and view rate (p = 0.008, r = -0.41). Contact lens insertion and removal videos uploaded by YouTubers had the highest view rate but the lowest quality. Videos made by companies included most essential elements.
- 17 October 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (6) , 603-608
YouTube as a learning source for contact lens insertion and removal
Contact lens neophytes often learn about contact lens insertion and removal through YouTube videos of unknown quality. This study evaluates the quality of soft contact lens insertion and removal videos on YouTube. A search for the keywords 'Contact lens insertion', 'Contact lens removal', 'Put in contact lens', and 'Take off contact lens' was performed on YouTube. The first 50 videos for each keyword were evaluated. The number of views, source of the publisher, days since upload, and video quality were scored based on the content in the videos. The maximum score of insertion and removal videos were 7 and 5 respectively. The videos were classified into three groups by publisher category: videos published by eye care professionals, companies and YouTubers. Only 45 contact lens insertion and 44 removal videos met the inclusion criteria and were analysed. Insertion and removal videos published by YouTubers had the highest view and view rate. However, their quality scores were significantly lower than videos published by eye care professionals and companies. Videos uploaded by companies had the highest scores (insertion: 5.00 ± 1.10; removal: 3.25 ± 0.75). The mean scores of insertion and removal videos published by YouTubers were 1.65 ± 0.93 and 1.00 ± 0.89, respectively, while the insertion and removal videos uploaded by eye care professionals scored 3.58 ± 2.07 and 2.75 ± 1.53, respectively. There was also a negative correlation between the quality scores and view rate (p = 0.008, r = -0.41). Contact lens insertion and removal videos uploaded by YouTubers had the highest view rate but the lowest quality. Videos made by companies included most essential elements.
- 1 August 2014
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 37 (4) , 267-272
Microbial adherence to cosmetic contact lenses
- 1 August 2014
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 37 (4) , 267-272
Microbial adherence to cosmetic contact lenses
- 1 July 2014
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 97 (4) , 337-340
Corneal epithelial cell viability of an ex vivo porcine eye model
The aim was to assess the consistency of corneal epithelial cell viability of an ex vivo porcine eye model. Six porcine eye models (four test and two control) were prepared for each experiment. The model has a computer-controlled mechanical arm, which could move the eyelid of the porcine eye and apply phosphate buffered saline to simulate blinking and lacrimation. The four test eyes were set up to simulate evaporative dry eyes with simulated lacrimation and blinking (one blink and one drop of buffered saline per minute) over three hours. Control A models were set up to collect pre-experimental baseline data, while those of control B were the same as the test eyes but without lacrimation and blinking simulation. All porcine eyes were kept in a closed chamber with temperature and humidity well controlled. After three hours, the cells of all eyes (except control A, which were assessed immediately before commencement of the experiment) were assessed. The eyes were first dipped into 0.4 per cent trypan blue solution. Following the dissection and separation of the cells, the number of dead cells were then counted under the microscope with a field size of 0.25 mm(2). The experiment was repeated 11 times. No significant differences were found in the number of dead cells among the four test eyes in both the central and peripheral cornea. There were significantly more dead cells in the test eyes compared to control A but significantly less when compared to control B. More dead cells were found in the central cornea than the peripheral cornea in the test eyes but the difference was not observed in controls A and B. Epithelial cell viabilities among the four porcine eye models with simulated lacrimation and blinking were consistent. The majority of cells were viable before the experiment and simulated lacrimation and blinking maintained more viable cells over time.
- 1 July 2014
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 97 (4) , 337-340
Corneal epithelial cell viability of an ex vivo porcine eye model
The aim was to assess the consistency of corneal epithelial cell viability of an ex vivo porcine eye model. Six porcine eye models (four test and two control) were prepared for each experiment. The model has a computer-controlled mechanical arm, which could move the eyelid of the porcine eye and apply phosphate buffered saline to simulate blinking and lacrimation. The four test eyes were set up to simulate evaporative dry eyes with simulated lacrimation and blinking (one blink and one drop of buffered saline per minute) over three hours. Control A models were set up to collect pre-experimental baseline data, while those of control B were the same as the test eyes but without lacrimation and blinking simulation. All porcine eyes were kept in a closed chamber with temperature and humidity well controlled. After three hours, the cells of all eyes (except control A, which were assessed immediately before commencement of the experiment) were assessed. The eyes were first dipped into 0.4 per cent trypan blue solution. Following the dissection and separation of the cells, the number of dead cells were then counted under the microscope with a field size of 0.25 mm(2). The experiment was repeated 11 times. No significant differences were found in the number of dead cells among the four test eyes in both the central and peripheral cornea. There were significantly more dead cells in the test eyes compared to control A but significantly less when compared to control B. More dead cells were found in the central cornea than the peripheral cornea in the test eyes but the difference was not observed in controls A and B. Epithelial cell viabilities among the four porcine eye models with simulated lacrimation and blinking were consistent. The majority of cells were viable before the experiment and simulated lacrimation and blinking maintained more viable cells over time.
- 1 April 2014
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 37 (2) , 116-119
Orthokeratology for slowing myopic progression in a pair of identical twins
- 1 April 2014
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 37 (2) , 116-119
Orthokeratology for slowing myopic progression in a pair of identical twins
- 1 December 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36, e24-e25
Effect of patients’ educational background on non-compliance behaviours in young adult contact lens wearers in Hong Kong
- 1 December 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36, e24-e25
Effect of patients’ educational background on non-compliance behaviours in young adult contact lens wearers in Hong Kong
- 1 December 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36, e4
Da Vinci Award 2013: Microbial adherence to cosmetic contact lenses
- 1 December 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36, e4
Da Vinci Award 2013: Microbial adherence to cosmetic contact lenses
- 30 April 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36 (2) , 62-65
Prevalence of papillary changes and folliculosis of the palpebral conjunctiva in asymptomatic Chinese children
- 30 April 2013
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 36 (2) , 62-65
Prevalence of papillary changes and folliculosis of the palpebral conjunctiva in asymptomatic Chinese children
- 1 August 2012
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 35 (4) , 180-184
Clinical performance of an orthokeratology lens fitted with the aid of a computer software in Chinese children
- 1 August 2012
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 35 (4) , 180-184
Clinical performance of an orthokeratology lens fitted with the aid of a computer software in Chinese children