Ozcan Atlam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ozcan Atlam has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Mohan Lal Kolhe
Faculty of Engineering and Science, University of Agder, 4604 Kristiansand, Norway
3 shared publications - Gökhan Dündar
Kocaeli University
2 shared publications Mohan Kolhe
University of Agder, Faculty of Engineering and Science, PO Box 422, Kristiansand, NO 4604, Norway
2 shared publicationsDario Bezmalinovic
1 shared publicationDurmuşoğlu
1 shared publication- Frano Barbir
FESB University of Split
1 shared publication
Latest Publications
- 19 January 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (3) , 2783-2797
A methodological framework for evaluating thermal fluids in solar power applications via the simple additive weighting technique
- 19 January 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (3) , 2783-2797
A methodological framework for evaluating thermal fluids in solar power applications via the simple additive weighting technique
- 8 March 2023
- Published by Springer Nature
- p. 289-300
Wind Potential and Wind Economics in Türkiye
- 8 March 2023
- Published by Springer Nature
- p. 347-354
Proton Exchange Membrane Fuel Cell Power Generation and Loss Analysis
- 8 March 2023
- Published by Springer Nature
- p. 347-354
Proton Exchange Membrane Fuel Cell Power Generation and Loss Analysis
- 1 April 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (24) , 13230-13239
A practical Equivalent Electrical Circuit model for Proton Exchange Membrane Fuel Cell (PEMFC) systems
- 1 April 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (24) , 13230-13239
A practical Equivalent Electrical Circuit model for Proton Exchange Membrane Fuel Cell (PEMFC) systems
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Performance analysis of photovoltaic powered dc motor — Propeller system
The application of autonomous directly photovoltaic (PV) powered electro-mechanical has received increasing attention for different applications (e.g. PV water pumping, PV powered cooling of arid climate greenhouses, solar vehicles etc). The PV array output is a nonlinear and time-dependent power supply that varies with solar intensity and cell temperature, so the performance characteristics of the directly PV-powered DC motor - propeller system are very different than when powered by a constant DC voltage. The focus of this work is to do performance analysis of directly PV-powered DC motor - propeller system. Through performance evaluation, it has been observed that power transfer matching, with respect to the maximum power points of the PV module and the operating points of the DC PM motor - propeller, mainly depend on the load parameters, DC motor parameters. The matching can be improved by selecting appropriate parameters of the DC motor and propeller load. In designing a DC motor (for directly PV powered system), it is very important to consider the PV array's locus of maximum operating points for a particular propeller load application. This analysis will be useful in developing a directly PV powered aerodynamic systems.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Performance analysis of photovoltaic powered dc motor — Propeller system
The application of autonomous directly photovoltaic (PV) powered electro-mechanical has received increasing attention for different applications (e.g. PV water pumping, PV powered cooling of arid climate greenhouses, solar vehicles etc). The PV array output is a nonlinear and time-dependent power supply that varies with solar intensity and cell temperature, so the performance characteristics of the directly PV-powered DC motor - propeller system are very different than when powered by a constant DC voltage. The focus of this work is to do performance analysis of directly PV-powered DC motor - propeller system. Through performance evaluation, it has been observed that power transfer matching, with respect to the maximum power points of the PV module and the operating points of the DC PM motor - propeller, mainly depend on the load parameters, DC motor parameters. The matching can be improved by selecting appropriate parameters of the DC motor and propeller load. In designing a DC motor (for directly PV powered system), it is very important to consider the PV array's locus of maximum operating points for a particular propeller load application. This analysis will be useful in developing a directly PV powered aerodynamic systems.
- 1 March 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 139 (1) , 60-63
Performance Analysis of PEM Fuel Cell with Varying Oxidant Supply Rates
In this work, the performance of proton exchange membrane (PEM) fuel cells has been analyzed for different oxidant (air and oxygen) flow rates (supplied at the cathode side). The performance analysis of a single PEM fuel cell coupled with a direct current (DC) permanent magnet motor (as load) was analyzed for air and oxygen. With an increase in the air flow rate, the maximum current values of the PEM fuel cell increase due to the reduction in the concentration of polarization losses (in the polarization curve) and the voltage regulation for the load increases. The maximum power production in a PEM fuel cell is a logarithmic function of different air flow rates. In this system, a DC permanent magnet motor with a reduction gear was used as a load on the PEM fuel cell. With the increase in air flow supply rates, the starting torque of the DC permanent magnet motor load improves. Also, a performance analysis was conducted for pure oxygen, and it has been observed that the PEM fuel cell provides a very...
- 1 March 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 139 (1) , 60-63
Performance Analysis of PEM Fuel Cell with Varying Oxidant Supply Rates
In this work, the performance of proton exchange membrane (PEM) fuel cells has been analyzed for different oxidant (air and oxygen) flow rates (supplied at the cathode side). The performance analysis of a single PEM fuel cell coupled with a direct current (DC) permanent magnet motor (as load) was analyzed for air and oxygen. With an increase in the air flow rate, the maximum current values of the PEM fuel cell increase due to the reduction in the concentration of polarization losses (in the polarization curve) and the voltage regulation for the load increases. The maximum power production in a PEM fuel cell is a logarithmic function of different air flow rates. In this system, a DC permanent magnet motor with a reduction gear was used as a load on the PEM fuel cell. With the increase in air flow supply rates, the starting torque of the DC permanent magnet motor load improves. Also, a performance analysis was conducted for pure oxygen, and it has been observed that the PEM fuel cell provides a very...
- 1 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 131-134
Empirical electrical modeling for a proton exchange membrane electrolyzer
The hydrogen (H2) economy is a proposal for the distribution of energy using hydrogen as an energy carrier (due to its high mass energy density) for reducing green house gas emissions. Energy conversion from renewable energy (RE) sources with suitable energy storage can play an important role in the development and operation of RE systems. The integrated intermittent RE system, (e.g. wind, solar energy systems) based on energy storage in the form of electrolytic H2, is considered a promising alternative to overcome the intermittence of the RE sources. In comparison to commonly used battery storage, H2 is well suited for seasonal storage applications due to its inherent high mass energy density. PEM based electrolysis has many advantages as compared to conventional alkaline based electrolysis e.g. smaller dimension and mass, lower power consumption, intrinsic ability to cope with transient electrical power variations, high degree of purity of gases and possibility of getting H2 compressed at higher pressure within the unit and more safety level. In this work, PEM electrolyzer model has been developed. Input current-voltage (I-V) characteristic of electrolyzer has been modeled by using the experimental analysis under steady state conditions at room temperature. The model is developed by using electrical equivalent circuit topology by considering useful power conversion and losses. Electrolytic H2 production rates are found out with respect to the input current and power. These experimental results are verified with the theoretical results and the relative errors are <;2%. The electrolytic H2 production rate increases linearly with current, but variation of electrolytic H2 production rate with the input electrical power is nonlinear (i.e. logarithmic). These are verified through the developed model also. This model will help to analyze energy system behavior where is stored in the electrolytic H2 form.
- 1 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 131-134
Empirical electrical modeling for a proton exchange membrane electrolyzer
The hydrogen (H2) economy is a proposal for the distribution of energy using hydrogen as an energy carrier (due to its high mass energy density) for reducing green house gas emissions. Energy conversion from renewable energy (RE) sources with suitable energy storage can play an important role in the development and operation of RE systems. The integrated intermittent RE system, (e.g. wind, solar energy systems) based on energy storage in the form of electrolytic H2, is considered a promising alternative to overcome the intermittence of the RE sources. In comparison to commonly used battery storage, H2 is well suited for seasonal storage applications due to its inherent high mass energy density. PEM based electrolysis has many advantages as compared to conventional alkaline based electrolysis e.g. smaller dimension and mass, lower power consumption, intrinsic ability to cope with transient electrical power variations, high degree of purity of gases and possibility of getting H2 compressed at higher pressure within the unit and more safety level. In this work, PEM electrolyzer model has been developed. Input current-voltage (I-V) characteristic of electrolyzer has been modeled by using the experimental analysis under steady state conditions at room temperature. The model is developed by using electrical equivalent circuit topology by considering useful power conversion and losses. Electrolytic H2 production rates are found out with respect to the input current and power. These experimental results are verified with the theoretical results and the relative errors are <;2%. The electrolytic H2 production rate increases linearly with current, but variation of electrolytic H2 production rate with the input electrical power is nonlinear (i.e. logarithmic). These are verified through the developed model also. This model will help to analyze energy system behavior where is stored in the electrolytic H2 form.
- 1 August 2011
- Published by Elsevier in Energy Conversion and Management
- Vol. 52 (8-9) , 2952-2957
Equivalent electrical model for a proton exchange membrane (PEM) electrolyser
- 1 August 2011
- Published by Elsevier in Energy Conversion and Management
- Vol. 52 (8-9) , 2952-2957