Jay B. Jeffries
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jay B. Jeffries has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Ronald K. Hanson
Stanford University
6 shared publications- Ritobrata Sur
Stanford University
3 shared publications J. Luque
Molecular Physics Laboratory, SRI International, Menlo Park, USA
2 shared publicationsKai Sun
Stanford University
2 shared publications- Shengkai Wang
Peking University
2 shared publications Xing Chao
Stanford University
2 shared publications
Latest Publications
- 30 September 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (20) , 24559-24565
Time-resolved in situ detection of CO in a shock tube using cavity-enhanced absorption spectroscopy with a quantum-cascade laser near 46µm
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 30 September 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (20) , 24559-24565
Time-resolved in situ detection of CO in a shock tube using cavity-enhanced absorption spectroscopy with a quantum-cascade laser near 46µm
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 6 May 2014
- Published by Springer Nature in Applied Physics B
- Vol. 117 (1) , 411-421
Application of wavelength-scanned wavelength-modulation spectroscopy H2O absorption measurements in an engineering-scale high-pressure coal gasifier
- 6 May 2014
- Published by Springer Nature in Applied Physics B
- Vol. 117 (1) , 411-421
Application of wavelength-scanned wavelength-modulation spectroscopy H2O absorption measurements in an engineering-scale high-pressure coal gasifier
- Open Access
- 9 April 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (8) , 9291-9300
Sensitive and rapid laser diagnostic for shock tube kinetics studies using cavity-enhanced absorption spectroscopy
We report the first application of cavity-enhanced absorption spectroscopy (CEAS) using a coherent light source for sensitive and rapid gaseous species time-history measurements in a shock tube. Off-axis alignment and fast scanning of the laser wavelength were used to minimize coupling noise in a low-finesse cavity. An absorption gain factor of 83 with a measurement time resolution of 20 µs was demonstrated for C2H2 detection using a near-infrared transition near 1537 nm, corresponding to a noise-equivalent detection limit of 20 ppm at 296 K and 76 ppm at 906 K at 50 kHz. This substantial gain in signal, relative to conventional single-pass absorption, will enable ultra-sensitive species detection in shock tube kinetics studies, particularly useful for measurements of minor species and for studies of dilute reactive systems.
- 9 April 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (8) , 9291-9300
Open AccessSensitive and rapid laser diagnostic for shock tube kinetics studies using cavity-enhanced absorption spectroscopy
We report the first application of cavity-enhanced absorption spectroscopy (CEAS) using a coherent light source for sensitive and rapid gaseous species time-history measurements in a shock tube. Off-axis alignment and fast scanning of the laser wavelength were used to minimize coupling noise in a low-finesse cavity. An absorption gain factor of 83 with a measurement time resolution of 20 µs was demonstrated for C2H2 detection using a near-infrared transition near 1537 nm, corresponding to a noise-equivalent detection limit of 20 ppm at 296 K and 76 ppm at 906 K at 50 kHz. This substantial gain in signal, relative to conventional single-pass absorption, will enable ultra-sensitive species detection in shock tube kinetics studies, particularly useful for measurements of minor species and for studies of dilute reactive systems.
- 16 November 2009
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (33) , 6492-6500
Two-color-absorption sensor for time-resolved measurements of gasoline concentration and temperature
A midinfrared absorption sensor for crank-angle-resolved in-cylinder measurements of gasoline concentration and gas temperature for spark-ignition internal-combustion engines is reported, and design considerations and validation testing in the controlled environments of a heated cell and shock-heated gases are discussed. Mid-IR laser light was tuned to transitions in the strong absorption bands associated with C—H stretching vibration near , and time-resolved fuel vapor concentration and gas temperature were determined simultaneously from the absorption at two different wavelengths. These two infrared laser wavelengths were simultaneously produced by difference-frequency generation, which combines a near-IR signal laser with two near-IR pump lasers in a periodically poled lithium niobate crystal. Injection current modulation of the pump lasers produced intensity modulation of the mid-IR, which allowed the transmitted signals from the two laser wavelengths to be detected on a single detector and separated by frequency demultiplexing. Injection current modulation produced a wavelength modulation synchronous with the intensity modulation for each of the laser wavelengths, and accurate measurement of the gasoline absorption signal required the effects of wavelength modulation to be considered. Validation experiments were conducted for a single-component hydrocarbon fuel (2,2,4-trimethyl-pentane, commonly known as iso-octane) and a gasoline blend in a heated static cell () and behind planar shock waves () in a shock tube. With a bandwidth of , the measured fuel concentrations agreed within 5% RMS and the measured temperature agreed within 3% RMS to the known values. The bandwidth is sufficient to resolve 1 crank-angle degree at .- 16 November 2009
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (33) , 6492-6500
Two-color-absorption sensor for time-resolved measurements of gasoline concentration and temperature
A midinfrared absorption sensor for crank-angle-resolved in-cylinder measurements of gasoline concentration and gas temperature for spark-ignition internal-combustion engines is reported, and design considerations and validation testing in the controlled environments of a heated cell and shock-heated gases are discussed. Mid-IR laser light was tuned to transitions in the strong absorption bands associated with C—H stretching vibration near , and time-resolved fuel vapor concentration and gas temperature were determined simultaneously from the absorption at two different wavelengths. These two infrared laser wavelengths were simultaneously produced by difference-frequency generation, which combines a near-IR signal laser with two near-IR pump lasers in a periodically poled lithium niobate crystal. Injection current modulation of the pump lasers produced intensity modulation of the mid-IR, which allowed the transmitted signals from the two laser wavelengths to be detected on a single detector and separated by frequency demultiplexing. Injection current modulation produced a wavelength modulation synchronous with the intensity modulation for each of the laser wavelengths, and accurate measurement of the gasoline absorption signal required the effects of wavelength modulation to be considered. Validation experiments were conducted for a single-component hydrocarbon fuel (2,2,4-trimethyl-pentane, commonly known as iso-octane) and a gasoline blend in a heated static cell () and behind planar shock waves () in a shock tube. With a bandwidth of , the measured fuel concentrations agreed within 5% RMS and the measured temperature agreed within 3% RMS to the known values. The bandwidth is sufficient to resolve 1 crank-angle degree at .- 11 November 2008
- Published by Springer Nature in Applied Physics B
- Vol. 94 (1) , 51-63
Measurements of high-pressure CO2 absorption near 2.0 μm and implications on tunable diode laser sensor design
- 11 November 2008
- Published by Springer Nature in Applied Physics B
- Vol. 94 (1) , 51-63
Measurements of high-pressure CO2 absorption near 2.0 μm and implications on tunable diode laser sensor design
- 17 September 2008
- Published by Springer Nature in Applied Physics B
- Vol. 93 (2-3) , 627-638
Two-wavelength mid-IR diagnostic for temperature and n-dodecane concentration in an aerosol shock tube
- 17 September 2008
- Published by Springer Nature in Applied Physics B
- Vol. 93 (2-3) , 627-638
Two-wavelength mid-IR diagnostic for temperature and n-dodecane concentration in an aerosol shock tube
- 1 November 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (31) , 6644-6652
Two-photon laser-induced fluorescence of atomic hydrogen in a diamond-depositing dc arcjet
Atomic hydrogen in the plume of a dc-arcjet plasma is monitored by use of two-photon excited laser-induced fluorescence (LIF) during the deposition of diamond film. The effluent of a dc-arc discharge in hydrogen and argon forms a luminous plume as it flows through a converging–diverging nozzle into a reactor. When a trace of methane (S and 3D levels with two photons near 205 nm, and the subsequent fluorescence is observed at Balmer-α near 656 nm. Spatially resolved LIF measurements of atomic hydrogen are made as a function of the ratio of hydrogen to argon feedstock gas, methane addition, and reactor pressure. At lower reactor pressures, time-resolved LIF measurements are used to verify our collisional quenching correction algorithm. The quenching rate coefficients for collisions with the major species in the arcjet (Ar, H, and H2) do not change with gas temperature variations in the plume (T < 2300 K). Corrections of the LIF intensity measurements for the spatial variation of collisional quenching are important to determine relative distributions of the atomic hydrogen concentration. The relative atomic hydrogen concentrations measured here are calibrated with an earlier calorimetric determination of the feedstock hydrogen dissociation to provide quantitative hydrogen-atom concentration distributions.
- 1 November 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (31) , 6644-6652
Two-photon laser-induced fluorescence of atomic hydrogen in a diamond-depositing dc arcjet
Atomic hydrogen in the plume of a dc-arcjet plasma is monitored by use of two-photon excited laser-induced fluorescence (LIF) during the deposition of diamond film. The effluent of a dc-arc discharge in hydrogen and argon forms a luminous plume as it flows through a converging–diverging nozzle into a reactor. When a trace of methane (S and 3D levels with two photons near 205 nm, and the subsequent fluorescence is observed at Balmer-α near 656 nm. Spatially resolved LIF measurements of atomic hydrogen are made as a function of the ratio of hydrogen to argon feedstock gas, methane addition, and reactor pressure. At lower reactor pressures, time-resolved LIF measurements are used to verify our collisional quenching correction algorithm. The quenching rate coefficients for collisions with the major species in the arcjet (Ar, H, and H2) do not change with gas temperature variations in the plume (T < 2300 K). Corrections of the LIF intensity measurements for the spatial variation of collisional quenching are important to determine relative distributions of the atomic hydrogen concentration. The relative atomic hydrogen concentrations measured here are calibrated with an earlier calorimetric determination of the feedstock hydrogen dissociation to provide quantitative hydrogen-atom concentration distributions.
- 24 August 2005
- Published by Springer Nature in Applied Physics B
- Vol. 81 (5) , 711-722
Development of a fast temperature sensor for combustion gases using a single tunable diode laser
- 24 August 2005
- Published by Springer Nature in Applied Physics B
- Vol. 81 (5) , 711-722
Development of a fast temperature sensor for combustion gases using a single tunable diode laser
- 1 November 2004
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 22 (6) , 2479-2486
Near-infrared diode laser hydrogen fluoride monitor for dielectric etch
A hydrogen fluoride (HF) monitor, using a tunable diode laser, is designed and used to detect the etch endpoints for dielectric film etching in a commercial plasma reactor. The reactor plasma contains HF, a reaction product of feedstock gas CF4 and the hydrogen-containing films (photoresist, SiOCH) on the substrate. A near-infrared diode laser is used to scan the P(3) transition in the first overtone of HF near 1.31μm to monitor changes in the level of HF concentration in the plasma. Using 200ms averaging and a signal modulation technique, we estimate a minimum detectable HF absorbance of 6×10−5 in the etch plasma, corresponding to an HF partial pressure of 0.03mTorr. The sensor could indicate, in situ, the SiOCH over tetraethoxysilane oxide (TEOS) trench endpoint, which was not readily discerned by optical emission. These measurements demonstrate the feasibility of a real-time diode laser-based sensor for etch endpoint monitoring and a potential for process control.
- 1 November 2004
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 22 (6) , 2479-2486
Near-infrared diode laser hydrogen fluoride monitor for dielectric etch
A hydrogen fluoride (HF) monitor, using a tunable diode laser, is designed and used to detect the etch endpoints for dielectric film etching in a commercial plasma reactor. The reactor plasma contains HF, a reaction product of feedstock gas CF4 and the hydrogen-containing films (photoresist, SiOCH) on the substrate. A near-infrared diode laser is used to scan the P(3) transition in the first overtone of HF near 1.31μm to monitor changes in the level of HF concentration in the plasma. Using 200ms averaging and a signal modulation technique, we estimate a minimum detectable HF absorbance of 6×10−5 in the etch plasma, corresponding to an HF partial pressure of 0.03mTorr. The sensor could indicate, in situ, the SiOCH over tetraethoxysilane oxide (TEOS) trench endpoint, which was not readily discerned by optical emission. These measurements demonstrate the feasibility of a real-time diode laser-based sensor for etch endpoint monitoring and a potential for process control.
- 1 January 2004
- Published by Springer Nature in Applied Physics B
- Vol. 78 (1) , 93-102
Cavity ring-down absorption and laser-induced fluorescence for quantitative measurements of CH radicals in low-pressure flames
- 1 January 2004
- Published by Springer Nature in Applied Physics B
- Vol. 78 (1) , 93-102
Cavity ring-down absorption and laser-induced fluorescence for quantitative measurements of CH radicals in low-pressure flames