Arie Feuer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arie Feuer has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Zvi Friedman
Department of Electrical Engineering Technion-Israel Institute of Technology 32000 Haifa Israel
3 shared publications - Graham Clifford Goodwin
The University of Newcastle
2 shared publications - Shai Dekel
School of mathematical sciences Tel-Aviv University GE Global Research
2 shared publications - Tamir Bendory
School of Electrical and Computer Engineering, Tel Aviv University, Tel Aviv 69978, Israel
2 shared publications Adi Rabinovich
Department of Electrical Engineering, Technion, Israel Institute of Technology, Haifa, Israel
1 shared publication- Amiram Allouche
Surf Communications Solution Ltd., Yokne’am 20692, Israel
1 shared publication
Latest Publications
- Open Access
Deep Learning Applied to Beamforming in Synthetic Aperture Ultrasound
Deep learning methods can be found in many medical imaging applications. Recently, those methods were applied directly to the RF ultrasound multi-channel data to enhance the quality of the reconstructed images. In this paper, we apply a deep neural network to medical ultrasound imaging in the beamforming stage. Specifically, we train the network using simulated multi-channel data from two arrays with different sizes, using a variety of direction of arrival (DOA) angles, and test its generalization performance on real cardiac data. We demonstrate that our method can be used to improve image quality over standard methods, both in terms of resolution and contrast. Alternatively, it can be used to reduce the number of elements in the array, while maintaining the image quality. The utility of our method is demonstrated on both simulated and real data.
Open AccessDeep Learning Applied to Beamforming in Synthetic Aperture Ultrasound
Deep learning methods can be found in many medical imaging applications. Recently, those methods were applied directly to the RF ultrasound multi-channel data to enhance the quality of the reconstructed images. In this paper, we apply a deep neural network to medical ultrasound imaging in the beamforming stage. Specifically, we train the network using simulated multi-channel data from two arrays with different sizes, using a variety of direction of arrival (DOA) angles, and test its generalization performance on real cardiac data. We demonstrate that our method can be used to improve image quality over standard methods, both in terms of resolution and contrast. Alternatively, it can be used to reduce the number of elements in the array, while maintaining the image quality. The utility of our method is demonstrated on both simulated and real data.
- 1 October 2016
- Published by Elsevier in Journal of Mathematical Analysis and Applications
- Vol. 442 (2) , 511-536
Robust recovery of stream of pulses using convex optimization
- 1 October 2016
- Published by Elsevier in Journal of Mathematical Analysis and Applications
- Vol. 442 (2) , 511-536
Robust recovery of stream of pulses using convex optimization
- Open Access
Robust Recovery of Stream of Pulses using Convex Optimization
This paper considers the problem of recovering the delays and amplitudes of a weighted superposition of pulses. This problem is motivated by a variety of applications such as ultrasound and radar. We show that for univariate and bivariate stream of pulses, one can recover the delays and weights to any desired accuracy by solving a tractable convex optimization problem, provided that a pulse-dependent separation condition is satisfied. The main result of this paper states that the recovery is robust to additive noise or model mismatch.
Open AccessRobust Recovery of Stream of Pulses using Convex Optimization
This paper considers the problem of recovering the delays and amplitudes of a weighted superposition of pulses. This problem is motivated by a variety of applications such as ultrasound and radar. We show that for univariate and bivariate stream of pulses, one can recover the delays and weights to any desired accuracy by solving a tractable convex optimization problem, provided that a pulse-dependent separation condition is satisfied. The main result of this paper states that the recovery is robust to additive noise or model mismatch.
- 15 August 2015
- Published by Springer Nature
- p. 522-529
Decomposition-Based Compression of Ultrasound Raw-Data
- 15 August 2015
- Published by Springer Nature
- p. 522-529
Decomposition-Based Compression of Ultrasound Raw-Data
- 12 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 60 (12) , 2521-2531
Multi-line acquisition with minimum variance beamforming in medical ultrasound imaging
In recent years, multiple-line acquisition (MLA) has been introduced to increase frame rate in cardiac ultrasound medical imaging. However, this method induces blocklike artifacts in the image. One approach suggested, synthetic transmit beamforming (STB), involves overlapping transmit beams which are then interpolated to remove the MLA blocking artifacts. Independently, the application of minimum variance (MV) beamforming has been suggested in the context of MLA. We demonstrate here that each approach is only a partial solution and that combining them provides a better result than applying either approach separately. This is demonstrated by using both simulated and real phantom data, as well as cardiac data. We also show that the STB-compensated MV beamfomer outperforms single-line acquisition (SLA) delay- and-sum in terms of lateral resolution.
- 12 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 60 (12) , 2521-2531
Multi-line acquisition with minimum variance beamforming in medical ultrasound imaging
In recent years, multiple-line acquisition (MLA) has been introduced to increase frame rate in cardiac ultrasound medical imaging. However, this method induces blocklike artifacts in the image. One approach suggested, synthetic transmit beamforming (STB), involves overlapping transmit beams which are then interpolated to remove the MLA blocking artifacts. Independently, the application of minimum variance (MV) beamforming has been suggested in the context of MLA. We demonstrate here that each approach is only a partial solution and that combining them provides a better result than applying either approach separately. This is demonstrated by using both simulated and real phantom data, as well as cardiac data. We also show that the STB-compensated MV beamfomer outperforms single-line acquisition (SLA) delay- and-sum in terms of lateral resolution.
- Open Access
Xampling in Ultrasound Imaging
Recent developments of new medical treatment techniques put challenging demands on ultrasound imaging systems in terms of both image quality and raw data size. Traditional sampling methods result in very large amounts of data, thus, increasing demands on processing hardware and limiting the exibility in the post-processing stages. In this paper, we apply Compressed Sensing (CS) techniques to analog ultrasound signals, following the recently developed Xampling framework. The result is a system with significantly reduced sampling rates which, in turn, means significantly reduced data size while maintaining the quality of the resulting images.
Open AccessXampling in Ultrasound Imaging
Recent developments of new medical treatment techniques put challenging demands on ultrasound imaging systems in terms of both image quality and raw data size. Traditional sampling methods result in very large amounts of data, thus, increasing demands on processing hardware and limiting the exibility in the post-processing stages. In this paper, we apply Compressed Sensing (CS) techniques to analog ultrasound signals, following the recently developed Xampling framework. The result is a system with significantly reduced sampling rates which, in turn, means significantly reduced data size while maintaining the quality of the resulting images.
- 31 January 2009
- Published by Elsevier in Journal of Visual Communication and Image Representation
- Vol. 20 (1) , 1-8
2D motion aided sampling and reconstruction
- 31 January 2009
- Published by Elsevier in Journal of Visual Communication and Image Representation
- Vol. 20 (1) , 1-8
2D motion aided sampling and reconstruction
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Time Reversal MIMO Architecture for Very Shallow Underwater Acoustic Communication
Under water acoustic communication using Multi Input Multi Output (MIMO) systems was shown to be effective in exploiting the time and spatial diversity characteristics of the underwater acoustic communication channel (UWAC). However, Inter Symbol Interferences (ISI) caused by the multipath phenomenon of the MIMO channel, affects the communication system performances. Our work shows that by using the Time Reversal (TR) technique, the channel capacity is achieved without the requirement for Channel State Information (CSI). A very shallow underwater sea trial was conducted. The results confirmed the validity of our analysis. It demonstrated that the 2X2 TR MIMO channel capacity is roughly 2 times larger than the non TR SISO channel capacity and is equivalent to the optimal MIMO system performances. Thus, our TR MIMO system (combined with a low level ISI mitigation) achieves the optimal MIMO system performances without the need for channel estimation.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Time Reversal MIMO Architecture for Very Shallow Underwater Acoustic Communication
Under water acoustic communication using Multi Input Multi Output (MIMO) systems was shown to be effective in exploiting the time and spatial diversity characteristics of the underwater acoustic communication channel (UWAC). However, Inter Symbol Interferences (ISI) caused by the multipath phenomenon of the MIMO channel, affects the communication system performances. Our work shows that by using the Time Reversal (TR) technique, the channel capacity is achieved without the requirement for Channel State Information (CSI). A very shallow underwater sea trial was conducted. The results confirmed the validity of our analysis. It demonstrated that the 2X2 TR MIMO channel capacity is roughly 2 times larger than the non TR SISO channel capacity and is equivalent to the optimal MIMO system performances. Thus, our TR MIMO system (combined with a low level ISI mitigation) achieves the optimal MIMO system performances without the need for channel estimation.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 226-230
Compression at the Source
In this work we propose a novel approach to simultaneous resolution enhancement in both spatial and temporal domains. We provide an analytical justification to our approach and prove that under certain system assumptions it is possible to reconstruct a signal perfectly from its non-uniform sub-samples. We establish mathematical framework for the reconstruction process under these assumptions and further show that these assumptions fit many typical video data-streams and thus, have not only theoretical value but also a practical implementation.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 226-230
Compression at the Source
In this work we propose a novel approach to simultaneous resolution enhancement in both spatial and temporal domains. We provide an analytical justification to our approach and prove that under certain system assumptions it is possible to reconstruct a signal perfectly from its non-uniform sub-samples. We establish mathematical framework for the reconstruction process under these assumptions and further show that these assumptions fit many typical video data-streams and thus, have not only theoretical value but also a practical implementation.