Xu Nie
Research Subjects
Xu Nie has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Weinong Chen
Purdue University
4 shared publicationsTusit Weerasooriya
U.S. Army Research Laboratory
3 shared publications- Weinong Chen
Purdue University
3 shared publications - Bo Song
Purdue University
1 shared publication Brett Sanborn
U.S. Army Research Laboratory
1 shared publicationJ. M. Caruthers
Purdue University
1 shared publication
Latest Publications
- 20 May 2016
- Published by Wolters Kluwer Health
- Vol. 34 (5) , 321-4
[Performance evaluation of two N95 filtering-facepiece respirators on decomposition products of sulfur hexafluoride].
To assess the filtration efficiency of two N95 filtering-facepiece respirators (FFRs) for the decomposition products of sulfur hexafluoride (SF6). Two types of N95 FFRs (the particulate and the acid-proof respirators) were selected in this study. The decomposition products of SF6, including particles, hydrogen fluoride (HF) and sulfur dioxide (SO2) , were measured under experimental condition by using TSI PortaCount Plus, fluorine ion-selective electrodes and spectrophotometer separately. The filtration efficiency was then calculated and compared. Both two models of N95 respirators had lowest filtration efficiency larger than 95% for particles under airflow ranged from 10 to 95 L/min. When exposed to different concentrations of HF (low: 0.00~1.99 mg/m(3), middle: 2.00~3.99 mg/m(3), high: >4 mg/m(3)) , the acid-proof N95 respirator was more effective than the particulate respirator (P10.00 mg/m(3)) , the acid-proof respirator showed a high filtration efficiency within exposure to 1.5 hours: 95.73%, 98.67%, 98.14%, and 97.78%, respectively, when exposure duration extended to 4 hours, the filtration efficiency of the acid-proof respirator decreased to 91.97%, 82.28%, 70.12%, and 58.56%, respectively. Both the particulate and the acid-proof N95 FFRs met national standards on the particulate filtration efficiency. The acid-proof N95 respirator demonstrates to be more effective in filtering HF and SO2 than the particulate respirator. The filtration efficiency could decrease to an unsafe condition under longer exposure duration, timely replacement of respirator is recommended at the workplace.
- 20 May 2016
- Published by Wolters Kluwer Health
- Vol. 34 (5) , 321-4
[Performance evaluation of two N95 filtering-facepiece respirators on decomposition products of sulfur hexafluoride].
To assess the filtration efficiency of two N95 filtering-facepiece respirators (FFRs) for the decomposition products of sulfur hexafluoride (SF6). Two types of N95 FFRs (the particulate and the acid-proof respirators) were selected in this study. The decomposition products of SF6, including particles, hydrogen fluoride (HF) and sulfur dioxide (SO2) , were measured under experimental condition by using TSI PortaCount Plus, fluorine ion-selective electrodes and spectrophotometer separately. The filtration efficiency was then calculated and compared. Both two models of N95 respirators had lowest filtration efficiency larger than 95% for particles under airflow ranged from 10 to 95 L/min. When exposed to different concentrations of HF (low: 0.00~1.99 mg/m(3), middle: 2.00~3.99 mg/m(3), high: >4 mg/m(3)) , the acid-proof N95 respirator was more effective than the particulate respirator (P10.00 mg/m(3)) , the acid-proof respirator showed a high filtration efficiency within exposure to 1.5 hours: 95.73%, 98.67%, 98.14%, and 97.78%, respectively, when exposure duration extended to 4 hours, the filtration efficiency of the acid-proof respirator decreased to 91.97%, 82.28%, 70.12%, and 58.56%, respectively. Both the particulate and the acid-proof N95 FFRs met national standards on the particulate filtration efficiency. The acid-proof N95 respirator demonstrates to be more effective in filtering HF and SO2 than the particulate respirator. The filtration efficiency could decrease to an unsafe condition under longer exposure duration, timely replacement of respirator is recommended at the workplace.
- 13 September 2012
- Published by Springer Nature
- p. 181-183
Kolsky Tension Bar for Samples with Very Low Strength
- 13 September 2012
- Published by Springer Nature
- p. 181-183
Kolsky Tension Bar for Samples with Very Low Strength
- 13 September 2012
- Published by Springer Nature
- p. 123-124
Inertia Effects in High-Rate Compression Experiments of Soft Materials
- 13 September 2012
- Published by Springer Nature
- p. 123-124
Inertia Effects in High-Rate Compression Experiments of Soft Materials
- 22 June 2012
- Published by Springer Nature in Experimental Mechanics
- Vol. 53 (1) , 67-75
High-Rate Progressive Failure of Borosilicate Glass under Mechanical Confinement at High Temperatures
- 22 June 2012
- Published by Springer Nature in Experimental Mechanics
- Vol. 53 (1) , 67-75
High-Rate Progressive Failure of Borosilicate Glass under Mechanical Confinement at High Temperatures
- 13 October 2011
- Published by Springer Nature in Experimental Mechanics
- Vol. 52 (2) , 135-143
Dynamic Equibiaxial Flexural Strength of Borosilicate Glass at High Temperatures
- 13 October 2011
- Published by Springer Nature in Experimental Mechanics
- Vol. 52 (2) , 135-143
Dynamic Equibiaxial Flexural Strength of Borosilicate Glass at High Temperatures
- 18 May 2011
- Published by Springer Nature
- p. 11-12
A Kolsky Torsion Bar Technique for Characterization of Dynamic Shear Response of Soft Materials
- 18 May 2011
- Published by Springer Nature
- p. 11-12
A Kolsky Torsion Bar Technique for Characterization of Dynamic Shear Response of Soft Materials
- 18 May 2011
- Published by Springer Nature
- p. 123-124
Dynamic Ring-on-Ring Equibiaxial Flexural Strength of Borosilicate Glass
- 18 May 2011
- Published by Springer Nature
- p. 123-124
Dynamic Ring-on-Ring Equibiaxial Flexural Strength of Borosilicate Glass
- 10 March 2011
- Published by Springer Nature in Experimental Mechanics
- Vol. 51 (9) , 1527-1534
A Kolsky Torsion Bar Technique for Characterization of Dynamic Shear Response of Soft Materials
- 10 March 2011
- Published by Springer Nature in Experimental Mechanics
- Vol. 51 (9) , 1527-1534
A Kolsky Torsion Bar Technique for Characterization of Dynamic Shear Response of Soft Materials
- 8 November 2010
- Published by Wiley in Journal of Applied Mechanics
- Vol. 78 (2) , 021009
Dynamic Tensile Response of Porcine Muscle
The stress-strain response of a porcine muscle along and perpendicular to the muscle fiber direction was characterized over a wide range of strain rates under uniaxial tension. A modified Kolsky tension bar was used to conduct the experiments at high strain rates. Tubular specimen geometry was used to achieve uniform loading within the specimen and to minimize lateral inertia effect. Loading pulse was controlled to facilitate constant strain rates and dynamic stress equilibrium. Quasi-static experiments were also performed to explore the rate effects over a wider range of strain rates. The results show that the nonlinear tensile stress-strain responses in both directions along and perpendicular to the fibers are highly sensitive to strain rates. Compared with high-rate compression response, the strain rate sensitivity in the tensile test is less dependent on the fiber orientation to the loading direction.
- 8 November 2010
- Published by Wiley in Journal of Applied Mechanics
- Vol. 78 (2) , 021009
Dynamic Tensile Response of Porcine Muscle
The stress-strain response of a porcine muscle along and perpendicular to the muscle fiber direction was characterized over a wide range of strain rates under uniaxial tension. A modified Kolsky tension bar was used to conduct the experiments at high strain rates. Tubular specimen geometry was used to achieve uniform loading within the specimen and to minimize lateral inertia effect. Loading pulse was controlled to facilitate constant strain rates and dynamic stress equilibrium. Quasi-static experiments were also performed to explore the rate effects over a wider range of strain rates. The results show that the nonlinear tensile stress-strain responses in both directions along and perpendicular to the fibers are highly sensitive to strain rates. Compared with high-rate compression response, the strain rate sensitivity in the tensile test is less dependent on the fiber orientation to the loading direction.
- 2 April 2008
- Published by Springer Nature in Experimental Mechanics
- Vol. 49 (4) , 451-458
Dynamic Tensile Testing of Soft Materials
- 2 April 2008
- Published by Springer Nature in Experimental Mechanics
- Vol. 49 (4) , 451-458
Dynamic Tensile Testing of Soft Materials