Shumpei Ozawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shumpei Ozawa has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
M Watanabe
Department of Physics, Gakushuin University, 1-5-1 Mejiro, Toshima-ku, Tokyo 980-8577, JAPAN
4 shared publicationsH. Fukuyama
Tohoku University 4 Institute of Multidisciplinary Research for Advanced Materials (IMRAM) 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
3 shared publicationsM Kitajima
3 shared publicationsM Ohgami
3 shared publicationsT Furukawa
3 shared publicationsT. Hibiya
Keio University 3 Graduate School of System Design and Management 4-1-1, Hiyoshi, Kohoku-ku, Yokohama 223-8526, Japan
3 shared publications
Latest Publications
- Open Access
- 6 December 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 327 (1) , 012020
Temperature dependence of surface tension of molten iron under reducing gas atmosphere
Surface tension of molten iron was measured under Ar-He-5vol.%H 2 gas by oscillating droplet method using electromagnetic levitation furnace in consideration of the temperature dependence of oxygen partial pressure, Po 2 , of the gas. For comparison, the measurement was carried under Ar-He atmosphere to fix the Po 2 of the inlet gas at 10-2 Pa. The surface tension was successfully measured over a wide temperature range of about 780K including undercooling condition. When Po 2 is fixed at 10-2 Pa, the surface tension increased and then decreased with increasing temperature like a boomerang shape. When the measurement was carried out under the H 2-containing gas atmosphere, the temperature dependence of the surface tension shows unique kink at around 1810K instead of liner relationship due to competition between the temperature dependence of the Po 2 and that of the equilibrium constant of oxygen adsorption reaction. The relationship between the calculated lnK ad with respect to inverse temperature using Szyszkowski model was different between the atmospheric gases.
- 6 December 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 327 (1) , 012020
Open AccessTemperature dependence of surface tension of molten iron under reducing gas atmosphere
Surface tension of molten iron was measured under Ar-He-5vol.%H 2 gas by oscillating droplet method using electromagnetic levitation furnace in consideration of the temperature dependence of oxygen partial pressure, Po 2 , of the gas. For comparison, the measurement was carried under Ar-He atmosphere to fix the Po 2 of the inlet gas at 10-2 Pa. The surface tension was successfully measured over a wide temperature range of about 780K including undercooling condition. When Po 2 is fixed at 10-2 Pa, the surface tension increased and then decreased with increasing temperature like a boomerang shape. When the measurement was carried out under the H 2-containing gas atmosphere, the temperature dependence of the surface tension shows unique kink at around 1810K instead of liner relationship due to competition between the temperature dependence of the Po 2 and that of the equilibrium constant of oxygen adsorption reaction. The relationship between the calculated lnK ad with respect to inverse temperature using Szyszkowski model was different between the atmospheric gases.
- 1 January 2011
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 109 (1) , 014902
Influence of oxygen partial pressure on surface tension and its temperature coefficient of molten iron
Influences of oxygen partial pressure, , of ambient atmosphere and temperature on surface tension and its temperature coefficient for molten iron were experimentally investigated by an oscillating droplet method using an electromagnetic levitation furnace. We successfully measured the surface tension of molten iron over a very wide temperature range of 780 K including undercooling condition in a well controlled atmosphere. When is fixed at at the inlet of the chamber, a “boomerang shape” temperature dependence of surface tension was experimentally observed; surface tension increased and then decreased with increasing temperature. The pure surface tension of molten iron was deduced from the negative temperature coefficient in the boomerang shape temperature dependence. When the surface tension was measured under the -containing gas atmosphere, surface tension did not show a linear relationship against temperature. The temperature dependence of the surface tension shows anomalous kink at around 1850 K due to competition between the temperature dependence of and that of the equilibrium constant of oxygen adsorption.- 1 January 2011
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 109 (1) , 014902
Influence of oxygen partial pressure on surface tension and its temperature coefficient of molten iron
Influences of oxygen partial pressure, , of ambient atmosphere and temperature on surface tension and its temperature coefficient for molten iron were experimentally investigated by an oscillating droplet method using an electromagnetic levitation furnace. We successfully measured the surface tension of molten iron over a very wide temperature range of 780 K including undercooling condition in a well controlled atmosphere. When is fixed at at the inlet of the chamber, a “boomerang shape” temperature dependence of surface tension was experimentally observed; surface tension increased and then decreased with increasing temperature. The pure surface tension of molten iron was deduced from the negative temperature coefficient in the boomerang shape temperature dependence. When the surface tension was measured under the -containing gas atmosphere, surface tension did not show a linear relationship against temperature. The temperature dependence of the surface tension shows anomalous kink at around 1850 K due to competition between the temperature dependence of and that of the equilibrium constant of oxygen adsorption.- 1 January 2010
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 107 (1) , 014910
Influence of oxygen partial pressure on surface tension of molten silver
Influences of oxygen partial pressure, , of ambient atmosphere and temperature on surface tension of molten silver were experimentally investigated by an oscillating droplet method using an electromagnetic levitation furnace. We successfully measured surface tension of molten silver within a very wide temperature range of over 550 K under a well-controlled atmosphere. Surface tension of pure melt surface, , was determined without any contamination such as oxygen adsorption and the reaction between the melt and a measurement device at a of less than . When the was controlled at , the “boomerang shape” temperature dependence of surface tension was experimentally observed; surface tension was increased and then decreased with increasing temperature. From these experimental data, the temperature dependence of equilibrium constant for oxygen adsorption was determined using the Szyszkowski equation. We successfully expressed the surface tension of molten silver as functions of both and temperature. Furthermore, the changes in enthalpy and entropy for oxygen adsorption on molten silver were also estimated.- 1 January 2010
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 107 (1) , 014910
Influence of oxygen partial pressure on surface tension of molten silver
Influences of oxygen partial pressure, , of ambient atmosphere and temperature on surface tension of molten silver were experimentally investigated by an oscillating droplet method using an electromagnetic levitation furnace. We successfully measured surface tension of molten silver within a very wide temperature range of over 550 K under a well-controlled atmosphere. Surface tension of pure melt surface, , was determined without any contamination such as oxygen adsorption and the reaction between the melt and a measurement device at a of less than . When the was controlled at , the “boomerang shape” temperature dependence of surface tension was experimentally observed; surface tension was increased and then decreased with increasing temperature. From these experimental data, the temperature dependence of equilibrium constant for oxygen adsorption was determined using the Szyszkowski equation. We successfully expressed the surface tension of molten silver as functions of both and temperature. Furthermore, the changes in enthalpy and entropy for oxygen adsorption on molten silver were also estimated.- 5 January 2009
- Published by Springer Nature
- p. 39-59
Marangoni Flow and Surface Tension of High Temperature Melts
- 5 January 2009
- Published by Springer Nature
- p. 39-59
Marangoni Flow and Surface Tension of High Temperature Melts
- 15 November 2008
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 495 (1-2) , 50-53
Oscillation behavior of a high-temperature silicon droplet by the electromagnetic levitation technique superimposed with a static magnetic field
- 15 November 2008
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 495 (1-2) , 50-53
Oscillation behavior of a high-temperature silicon droplet by the electromagnetic levitation technique superimposed with a static magnetic field
- 1 October 2001
- Vol. 8, 86S-89S
Laparoscopic detection of sentinel lymph nodes in gastrointestinal cancer: a novel and minimally invasive approach.
Although the sentinel node (SN) concept has been validated in malignant melanoma and breast cancer, the application of this concept for other solid tumors, including gastrointestinal (GI) cancer, is still controversial. We have demonstrated the feasibility of radioguided SN mapping during laparotomy in patients with esophageal, gastric, and colorectal cancers. In 188 patients, the SNs identified by this technique had an overall diagnostic accuracy of 96% for regional lymph node metastasis. Aberrant drainage sites that have been called skip metastasis from the primary lesion were detectable using this method. More recently, we have undertaken SN mapping during laparoscopic surgery. A combination of radiotracer and blue dye optimized the identification of SNs that drained GI cancers. Our preliminary data indicate that laparoscopic mapping of the SN is a sensitive intraoperative technique for identifying lymph node micrometastasis, and we believe that it will become an important component of a minimally invasive approach to early-stage GI cancers.
- 1 October 2001
- Vol. 8, 86S-89S
Laparoscopic detection of sentinel lymph nodes in gastrointestinal cancer: a novel and minimally invasive approach.
Although the sentinel node (SN) concept has been validated in malignant melanoma and breast cancer, the application of this concept for other solid tumors, including gastrointestinal (GI) cancer, is still controversial. We have demonstrated the feasibility of radioguided SN mapping during laparotomy in patients with esophageal, gastric, and colorectal cancers. In 188 patients, the SNs identified by this technique had an overall diagnostic accuracy of 96% for regional lymph node metastasis. Aberrant drainage sites that have been called skip metastasis from the primary lesion were detectable using this method. More recently, we have undertaken SN mapping during laparoscopic surgery. A combination of radiotracer and blue dye optimized the identification of SNs that drained GI cancers. Our preliminary data indicate that laparoscopic mapping of the SN is a sensitive intraoperative technique for identifying lymph node micrometastasis, and we believe that it will become an important component of a minimally invasive approach to early-stage GI cancers.
- 1 March 2000
- Vol. 101 (3) , 293-8
[Surgery using master-slave manipulators and telementoring].
Master-slave manipulators enhance surgeons' dexterity and improve the precision of surgical techniques by filtering out surgeons' tremors and scaling the movements of surgical instruments. Among clinically available master-slave manipulators, the epoch-making system called "da Vinci" developed by Intuitive Surgical Inc. (Mountain View, CA, USA), equipped with 2 articulated joints at the tip of the surgical instruments allowing 7 degrees of freedom, mimics the movements of surgeons' wrists and fingers in the abdominal or thoracic cavity. Today advanced telecommunications technology provides us excellent motion images using only 3-ISDN telephone lines. Experienced surgeons at primary surgical sites have been able to perform complex procedures successfully by consulting specialists at remote sites. Because telecommunications costs have become lower each year, telementoring will be come a routine surgical practice in the near future. The usefulness of surgical telementoring has been greatly enhanced by the development of a technique to illustrate on video images from two directions. Moreover, remote advisory surgeons will be able to provide the optimal operative field to operating surgeons using robotic camera holders with voice-recognition systems. In the near future, when master-slave manipulators will also be coupled with telementoring systems, remote experts could actually perform complex surgical procedures.
- 1 March 2000
- Vol. 101 (3) , 293-8
[Surgery using master-slave manipulators and telementoring].
Master-slave manipulators enhance surgeons' dexterity and improve the precision of surgical techniques by filtering out surgeons' tremors and scaling the movements of surgical instruments. Among clinically available master-slave manipulators, the epoch-making system called "da Vinci" developed by Intuitive Surgical Inc. (Mountain View, CA, USA), equipped with 2 articulated joints at the tip of the surgical instruments allowing 7 degrees of freedom, mimics the movements of surgeons' wrists and fingers in the abdominal or thoracic cavity. Today advanced telecommunications technology provides us excellent motion images using only 3-ISDN telephone lines. Experienced surgeons at primary surgical sites have been able to perform complex procedures successfully by consulting specialists at remote sites. Because telecommunications costs have become lower each year, telementoring will be come a routine surgical practice in the near future. The usefulness of surgical telementoring has been greatly enhanced by the development of a technique to illustrate on video images from two directions. Moreover, remote advisory surgeons will be able to provide the optimal operative field to operating surgeons using robotic camera holders with voice-recognition systems. In the near future, when master-slave manipulators will also be coupled with telementoring systems, remote experts could actually perform complex surgical procedures.
- 1 March 2000
- Vol. 101 (3) , 315-9
[The validity of the sentinel node concept in gastrointestinal cancers].
Although the sentinel node concept has been validated and clinically applied to breast cancer and malignant melanoma, its clinical significance in other solid tumors has not been thoroughly investigated. With regard to gastrointestinal (GI) cancers in particular, our surgeons have been cautious because of the high frequency of skip metastasis and the complicated lymphatic system in the GI tract. We would like to emphasize that so-called skip metastasis has been defined according to anatomic classification of regional lymph nodes and that the lymphatic drainage route must be patient or lesion specific. To test the validity and feasibility of this concept in GI cancers, we have established a radio-guided intraoperative sentinel node navigation system using preoperative endoscopic submucosal injection of radioactive tracer followed by intra-operative gamma-probing. In 131 patients with GI cancers (esophagus: 22, stomach: 71, colorectum: 38), the detection rate of sentinel nades was 91% and overall diagnostic accuracy of lymph node metastasis by sentinel node status was 97%. Initial results suggest further investigation of this procedure as an accurate staging and a minimally invasive approach to early GI cancers.
- 1 March 2000
- Vol. 101 (3) , 315-9
[The validity of the sentinel node concept in gastrointestinal cancers].
Although the sentinel node concept has been validated and clinically applied to breast cancer and malignant melanoma, its clinical significance in other solid tumors has not been thoroughly investigated. With regard to gastrointestinal (GI) cancers in particular, our surgeons have been cautious because of the high frequency of skip metastasis and the complicated lymphatic system in the GI tract. We would like to emphasize that so-called skip metastasis has been defined according to anatomic classification of regional lymph nodes and that the lymphatic drainage route must be patient or lesion specific. To test the validity and feasibility of this concept in GI cancers, we have established a radio-guided intraoperative sentinel node navigation system using preoperative endoscopic submucosal injection of radioactive tracer followed by intra-operative gamma-probing. In 131 patients with GI cancers (esophagus: 22, stomach: 71, colorectum: 38), the detection rate of sentinel nades was 91% and overall diagnostic accuracy of lymph node metastasis by sentinel node status was 97%. Initial results suggest further investigation of this procedure as an accurate staging and a minimally invasive approach to early GI cancers.