Takeshi Morita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takeshi Morita has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Keiko Nishikawa
Department of Chemistry, Faculty of Education, Aichi University of Education, Hirosawa 1, Igaya, Kariya, Aichi 448-8542, Japan, and Division of Nanoscience, Graduate School of Advanced Integration Sciences, Chiba University, Yayoi, Inage-ku, Chiba 263-8522, Japan
2 shared publicationsEiichi Tanaka
Department of Chemistry, Faculty of Education, Aichi University of Education, Hirosawa 1, Igaya, Kariya, Aichi 448-8542, Japan, and Division of Nanoscience, Graduate School of Advanced Integration Sciences, Chiba University, Yayoi, Inage-ku, Chiba 263-8522, Japan
1 shared publication- Hirofumi Nakano
Aichi University of Education
1 shared publication Hiromi Murai
Department of Chemistry, Faculty of Education, Aichi University of Education, Hirosawa 1, Igaya, Kariya, Aichi 448-8542, Japan, and Division of Nanoscience, Graduate School of Advanced Integration Sciences, Chiba University, Yayoi, Inage-ku, Chiba 263-8522, Japan
1 shared publicationHiroyasu Hotta
Department of Chemistry, Faculty of Education, Aichi University of Education, Hirosawa 1, Igaya, Kariya, Aichi 448-8542, Japan, and Division of Nanoscience, Graduate School of Advanced Integration Sciences, Chiba University, Yayoi, Inage-ku, Chiba 263-8522, Japan
1 shared publicationKazuki Ito
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo, Hyogo 679-5148, Japan
1 shared publication
Latest Publications
- 12 February 2010
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 114 (9) , 3804-3810
Aspect-Ratio Dependence on Formation Process of Gold Nanorods Studied by Time-Resolved Distance Distribution Functions
- 12 February 2010
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 114 (9) , 3804-3810
Aspect-Ratio Dependence on Formation Process of Gold Nanorods Studied by Time-Resolved Distance Distribution Functions
- 14 July 2009
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 526 (1-2) , 118-122
Relation between local necking and cavitation during high-temperature tensile deformation of polycrystalline pure aluminum
- 14 July 2009
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 526 (1-2) , 118-122
Relation between local necking and cavitation during high-temperature tensile deformation of polycrystalline pure aluminum
- 13 July 2007
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 40 (4) , 791-795
Apparatus for the simultaneous measurement of the X-ray absorption factor developed for a small-angle X-ray scattering beamline
A novel apparatus has been developed that enables the simultaneous determination of the absorption factor during measurement of small-angle X-ray scattering (SAXS) intensities of a sample. It was designed especially for the use of relatively low-energy X-rays at SAXS beamlines of synchrotron facilities. The X-ray intensity of transmittance is measured by a silicon PIN photodiode, which is implanted in a direct beamstop set in a vacuum chamber. Since the assembly transmits an attenuated direct beam to a detector during the scattering measurement, a zero-angle position can be monitored without additional operation. It was confirmed that the linearity between the signal from the photodiode and the intensity of X-rays is good and the photodiode is applicable for the desired purpose. For a performance test, the absorption factors of a supercritical fluid were measured with a wide density range.
- 13 July 2007
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 40 (4) , 791-795
Apparatus for the simultaneous measurement of the X-ray absorption factor developed for a small-angle X-ray scattering beamline
A novel apparatus has been developed that enables the simultaneous determination of the absorption factor during measurement of small-angle X-ray scattering (SAXS) intensities of a sample. It was designed especially for the use of relatively low-energy X-rays at SAXS beamlines of synchrotron facilities. The X-ray intensity of transmittance is measured by a silicon PIN photodiode, which is implanted in a direct beamstop set in a vacuum chamber. Since the assembly transmits an attenuated direct beam to a detector during the scattering measurement, a zero-angle position can be monitored without additional operation. It was confirmed that the linearity between the signal from the photodiode and the intensity of X-rays is good and the photodiode is applicable for the desired purpose. For a performance test, the absorption factors of a supercritical fluid were measured with a wide density range.