Latest Publications
- 16 July 2012
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 4 (3) , 031005
New Thermal Management Systems for Data Centers
Energy consumption in data centers has seen a drastic increase in recent years. In data centers, server racks are cooled down in an indirect way by air-conditioning systems installed to cool the entire server room. This air cooling method is inefficient as information technology (IT) equipment is insufficiently cooled down, whereas the room is overcooled. The development of countermeasures for heat generated by IT equipment is one of the urgent tasks to be accomplished. We, therefore, proposed new liquid cooling systems in which IT equipment is cooled down directly and exhaust heat is not radiated into the server room. Three cooling methods have been developed simultaneously. Two of them involve direct cooling; a cooling jacket is directly attached to the heat source (or CPU in this case) and a single-phase heat exchanger or a two-phase heat exchanger is used as the cooling jacket. The other method involves indirect cooling; heat generated by CPU is transported to the outside of the chassis through flat heat pipes and the condensation sections of the heat pipes are cooled down by coolant with liquid manifold. Verification tests have been conducted by using commercial server racks to which these cooling methods are applied while investigating five R&D components that constitute our liquid cooling systems: the single-phase heat exchanger, the two-phase heat exchanger, high performance flat heat pipes, nanofluid technology, and the plug-in connector. As a result, a 44–53% reduction in energy consumption of cooling facilities with the single-phase cooling system and a 42–50% reduction with the flat heat pipe cooling system were realized compared with conventional air cooling system.
- 16 July 2012
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 4 (3) , 031005
New Thermal Management Systems for Data Centers
Energy consumption in data centers has seen a drastic increase in recent years. In data centers, server racks are cooled down in an indirect way by air-conditioning systems installed to cool the entire server room. This air cooling method is inefficient as information technology (IT) equipment is insufficiently cooled down, whereas the room is overcooled. The development of countermeasures for heat generated by IT equipment is one of the urgent tasks to be accomplished. We, therefore, proposed new liquid cooling systems in which IT equipment is cooled down directly and exhaust heat is not radiated into the server room. Three cooling methods have been developed simultaneously. Two of them involve direct cooling; a cooling jacket is directly attached to the heat source (or CPU in this case) and a single-phase heat exchanger or a two-phase heat exchanger is used as the cooling jacket. The other method involves indirect cooling; heat generated by CPU is transported to the outside of the chassis through flat heat pipes and the condensation sections of the heat pipes are cooled down by coolant with liquid manifold. Verification tests have been conducted by using commercial server racks to which these cooling methods are applied while investigating five R&D components that constitute our liquid cooling systems: the single-phase heat exchanger, the two-phase heat exchanger, high performance flat heat pipes, nanofluid technology, and the plug-in connector. As a result, a 44–53% reduction in energy consumption of cooling facilities with the single-phase cooling system and a 42–50% reduction with the flat heat pipe cooling system were realized compared with conventional air cooling system.
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2010, 77-78
C131 Development of Cooling Jacket for Electronics Devices by Using Flow Boiling in Narrow Channels
A cooling jacket for electronics devices, composed of a main heated channel with grooves and auxiliary unheated channels for additional liquid supply, was developed. The structure prevents dryout phenomena, i.e. the heat transfer limitation in boiling, by the reduction of substantial heated length. The heating surface, with a length of 30mm and a width of 30mm, was installed horizontally facing upwards in the cooling jacket. Test liquid was selected as FC72 to keep electric insulation from semiconductors integrated in the server. The measured critical heat flux (CHF) was larger than 33.3×10^4W/m^2 (300W) for inlet volumetric flow rate V_ = 0.8l/min and 1.0l/min (mass velocity G_ = 372kg/m^2 and 466kg/m^2s, respectively) at inlet liquid temperature T_ = 35℃ and test pressure P=0.15MPa. Larger CHF values compared to those for the channel without auxiliary unheated channels were confirmed.
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2010, 77-78
C131 Development of Cooling Jacket for Electronics Devices by Using Flow Boiling in Narrow Channels
A cooling jacket for electronics devices, composed of a main heated channel with grooves and auxiliary unheated channels for additional liquid supply, was developed. The structure prevents dryout phenomena, i.e. the heat transfer limitation in boiling, by the reduction of substantial heated length. The heating surface, with a length of 30mm and a width of 30mm, was installed horizontally facing upwards in the cooling jacket. Test liquid was selected as FC72 to keep electric insulation from semiconductors integrated in the server. The measured critical heat flux (CHF) was larger than 33.3×10^4W/m^2 (300W) for inlet volumetric flow rate V_ = 0.8l/min and 1.0l/min (mass velocity G_ = 372kg/m^2 and 466kg/m^2s, respectively) at inlet liquid temperature T_ = 35℃ and test pressure P=0.15MPa. Larger CHF values compared to those for the channel without auxiliary unheated channels were confirmed.
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2010, 69-70
C121 Development of High Performance Thin Flat Heat Pipes
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2010, 69-70
C121 Development of High Performance Thin Flat Heat Pipes
- 1 January 2010
- Published by ASME International
- p. 425-430
Development of Advanced Cooling Network Systems for Data Centers
Energy utilization in data centers, especially cooling systems for server racks, needs extensive improvement. The present authors proposed advanced cooling network systems for data centers, and R & D activities have been conducted under the so-called Green IT Project sponsored by NEDO (New Energy and Industrial Technology Development Organization). In the present concept, CPUs in servers are cooled down by either direct liquid cooling system or heat pipes with liquid cooling systems in the condensation region. The liquid cooling systems are integrated in each server rack and among server racks. A series of studies on both single phase and two phase narrow channel heat exchangers, high performance heat pipes with self-rewetting fluids and nanofluids for heat transfer enhancement are ongoing. In addition, a prototype server rack with the cooling network systems is also under development toward commercial products. This paper reports the updated status of the present R & D.
- 1 January 2010
- Published by ASME International
- p. 425-430
Development of Advanced Cooling Network Systems for Data Centers
Energy utilization in data centers, especially cooling systems for server racks, needs extensive improvement. The present authors proposed advanced cooling network systems for data centers, and R & D activities have been conducted under the so-called Green IT Project sponsored by NEDO (New Energy and Industrial Technology Development Organization). In the present concept, CPUs in servers are cooled down by either direct liquid cooling system or heat pipes with liquid cooling systems in the condensation region. The liquid cooling systems are integrated in each server rack and among server racks. A series of studies on both single phase and two phase narrow channel heat exchangers, high performance heat pipes with self-rewetting fluids and nanofluids for heat transfer enhancement are ongoing. In addition, a prototype server rack with the cooling network systems is also under development toward commercial products. This paper reports the updated status of the present R & D.
- 17 April 2009
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1161 (1) , 554-561
Low‐Gravity Experiments of Lightweight Flexible Heat Pipe Panels with Self‐Rewetting Fluids
Fluids with a unique surface tension behavior, the so‐called “self‐rewetting fluids,” are considered to be promising working fluids not only in reduced‐gravity environments but also in terrestrial applications. Ultralightweight polyimide‐based wickless heat pipe panels with flexible, inflatable, and deployable functions were fabricated using self‐rewetting fluids. Fundamental operation tests of these panels were conducted under conditions of reduced gravity during parabolic flight. We obtained promising experimental results on the thermal performance of the panels in reduced gravity, although the experimental conditions were not entirely satisfactory.
- 17 April 2009
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1161 (1) , 554-561
Low‐Gravity Experiments of Lightweight Flexible Heat Pipe Panels with Self‐Rewetting Fluids
Fluids with a unique surface tension behavior, the so‐called “self‐rewetting fluids,” are considered to be promising working fluids not only in reduced‐gravity environments but also in terrestrial applications. Ultralightweight polyimide‐based wickless heat pipe panels with flexible, inflatable, and deployable functions were fabricated using self‐rewetting fluids. Fundamental operation tests of these panels were conducted under conditions of reduced gravity during parabolic flight. We obtained promising experimental results on the thermal performance of the panels in reduced gravity, although the experimental conditions were not entirely satisfactory.
- 1 January 2009
- Published by ASME International
- p. 283-292
Development of Advanced High Heat Flux Cooling System for Power Electronics
Recent development in electronic devices with increased heat dissipation requires severe cooling conditions and an efficient method for heat removal is needed for the cooling under high heat flux conditions. Most researches are concentrated on small semiconductors with high heat flux density, while almost no existing researches concerning the cooling of a large semiconductor, i.e. power electronics, with high heat generation density from a large cooling area. A narrow channel between parallel plates is one of ideal structures for the application of boiling phenomena which uses the cooling for such large semiconductors. To develop high-performance cooling systems for power electronics, experiments on increase in critical heat flux (CHF) for flow boiling in narrow channels by improved liquid supply was conducted. To realize the cooling of large areas at extremely high heat flux under the conditions for a minimum gap size and a minimum flow rate of liquid supplied, the structure with auxiliary liquid supply was devised to prevent the extension of dry-patches underneath flattened bubbles generated in a narrow channel. The heating surface was experimented in two channels with different dimensions. The heating surfaces have the width of 30mm and the lengths of 50mm and 150mm in the flow direction. A large width of actual power electronics is realizable by the parallel installation of the same channel structure in the transverse direction. The cooling liquid is additionally supplied via sintered metal plates from the auxiliary unheated channels located at sides or behind the main heated channel. To supply the liquid to the entire heating surface, fine grooves are machined on the heating surface for enhance the spontaneous liquid supply by the aid of capillary force. The gap size of narrow channels are varied as 0.7mm, 2mm and 5mm. Distribution of liquid flow rate to the main heated channel and the auxiliary unheated channels were varied to investigate its effect on the critical heat flux. Test liquids employed are R113, FC72 and water. The systematic experiments by using water as a test liquid were conducted. Critical heat flux values larger than 2×106W/m2 were obtained at both gap sizes of 2mm and 5mm for a heated length of 150mm. A very high heat transfer coefficient as much as 1×105W/m2K was obtained at very high heat flux near CHF for the gap size of 2mm. This paper is a summary of experimental results obtained in the past by the present authors.
- 1 January 2009
- Published by ASME International
- p. 283-292
Development of Advanced High Heat Flux Cooling System for Power Electronics
Recent development in electronic devices with increased heat dissipation requires severe cooling conditions and an efficient method for heat removal is needed for the cooling under high heat flux conditions. Most researches are concentrated on small semiconductors with high heat flux density, while almost no existing researches concerning the cooling of a large semiconductor, i.e. power electronics, with high heat generation density from a large cooling area. A narrow channel between parallel plates is one of ideal structures for the application of boiling phenomena which uses the cooling for such large semiconductors. To develop high-performance cooling systems for power electronics, experiments on increase in critical heat flux (CHF) for flow boiling in narrow channels by improved liquid supply was conducted. To realize the cooling of large areas at extremely high heat flux under the conditions for a minimum gap size and a minimum flow rate of liquid supplied, the structure with auxiliary liquid supply was devised to prevent the extension of dry-patches underneath flattened bubbles generated in a narrow channel. The heating surface was experimented in two channels with different dimensions. The heating surfaces have the width of 30mm and the lengths of 50mm and 150mm in the flow direction. A large width of actual power electronics is realizable by the parallel installation of the same channel structure in the transverse direction. The cooling liquid is additionally supplied via sintered metal plates from the auxiliary unheated channels located at sides or behind the main heated channel. To supply the liquid to the entire heating surface, fine grooves are machined on the heating surface for enhance the spontaneous liquid supply by the aid of capillary force. The gap size of narrow channels are varied as 0.7mm, 2mm and 5mm. Distribution of liquid flow rate to the main heated channel and the auxiliary unheated channels were varied to investigate its effect on the critical heat flux. Test liquids employed are R113, FC72 and water. The systematic experiments by using water as a test liquid were conducted. Critical heat flux values larger than 2×106W/m2 were obtained at both gap sizes of 2mm and 5mm for a heated length of 150mm. A very high heat transfer coefficient as much as 1×105W/m2K was obtained at very high heat flux near CHF for the gap size of 2mm. This paper is a summary of experimental results obtained in the past by the present authors.
- 1 January 2009
- Published by ASME International
- p. 619-624
Advanced Integrated Cooling Systems for Thermal Management in Data Centers
For a drastic energy conservation in data centers (more than 30%), a new advanced concept of thermal management systems of integrated cooling network in server racks is proposed, and a series of developmental studies toward the realization of the concept have been conducted. The concept consists of the following technological items: - Plug-in thermal network cables, - Narrow channel heat exchangers (single-phase and two-phase), - Thin flat-type heat pipes, - Development of nano-fluids for heat transfer enhancement. In this concept, CPUs in server racks are directly cooled with the aid of advanced 1.5 mm thick flat-type heat pipes or 3 mm thick narrow channel heat exchangers, though CPUs in server racks, at present, are cooled down with massive heat sinks by forced air flow in the racks. In the case of heat pipes, condensation regions are cooled by either single-phase or two-phase narrow channel heat sink instead of air-cooled finned heat sink. These cooling units are accommodated in server racks. In addition, plug-in thermal network cables, in which a working fluid for narrow channel heat exchangers is running, are integrated among server racks, and thermal energy dissipated in server racks are inclusively merged and managed by the thermal network cables. The working fluid heated up by the dissipated heat is recuperated in an outdoor cooling system. An attempt at the applications of silver nano-fluids as a working fluid in heat pipes and thermal network is also conducted in the present study. Silver nano-fluids are thermochemically synthesized by a microwave heating technique, which allows for superior stable suspension characteristics.
- 1 January 2009
- Published by ASME International
- p. 619-624
Advanced Integrated Cooling Systems for Thermal Management in Data Centers
For a drastic energy conservation in data centers (more than 30%), a new advanced concept of thermal management systems of integrated cooling network in server racks is proposed, and a series of developmental studies toward the realization of the concept have been conducted. The concept consists of the following technological items: - Plug-in thermal network cables, - Narrow channel heat exchangers (single-phase and two-phase), - Thin flat-type heat pipes, - Development of nano-fluids for heat transfer enhancement. In this concept, CPUs in server racks are directly cooled with the aid of advanced 1.5 mm thick flat-type heat pipes or 3 mm thick narrow channel heat exchangers, though CPUs in server racks, at present, are cooled down with massive heat sinks by forced air flow in the racks. In the case of heat pipes, condensation regions are cooled by either single-phase or two-phase narrow channel heat sink instead of air-cooled finned heat sink. These cooling units are accommodated in server racks. In addition, plug-in thermal network cables, in which a working fluid for narrow channel heat exchangers is running, are integrated among server racks, and thermal energy dissipated in server racks are inclusively merged and managed by the thermal network cables. The working fluid heated up by the dissipated heat is recuperated in an outdoor cooling system. An attempt at the applications of silver nano-fluids as a working fluid in heat pipes and thermal network is also conducted in the present study. Silver nano-fluids are thermochemically synthesized by a microwave heating technique, which allows for superior stable suspension characteristics.
- 1 October 2007
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 19 (3-4) , 11-12
Terrestrial and microgravity applications of self-rewetting fluids
- 1 October 2007
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 19 (3-4) , 11-12
Terrestrial and microgravity applications of self-rewetting fluids
- 1 September 2006
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 18 (3-4) , 178-183
Optical emission spectroscopic study for diagnostics in high gravity DC-plasma CVD diamond growth
- 1 September 2006
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 18 (3-4) , 178-183
Optical emission spectroscopic study for diagnostics in high gravity DC-plasma CVD diamond growth
- 1 September 2006
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1077 (1) , 650-667
Self‐Rewetting Fluids
Abstract: This paper reviews a series of my heat transfer studies of on the so‐called “self‐rewetting” fluids, in which the Marangoni effect due to concentration gradient and the thermocapillary flow cooperatively result in a strong liquid inflow at the nucleation sites in the course of boiling. First of all, the background of the study and our first attempt at heat transfer enhancement in microgravity boiling are introduced. Succeeding fundamental vapor bubble experiments are then briefly depicted. The current progress for applications to space and terrestrial thermal management devices, the main topic of the paper, is described in more detail.
- 1 September 2006
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1077 (1) , 650-667
Self‐Rewetting Fluids
Abstract: This paper reviews a series of my heat transfer studies of on the so‐called “self‐rewetting” fluids, in which the Marangoni effect due to concentration gradient and the thermocapillary flow cooperatively result in a strong liquid inflow at the nucleation sites in the course of boiling. First of all, the background of the study and our first attempt at heat transfer enhancement in microgravity boiling are introduced. Succeeding fundamental vapor bubble experiments are then briefly depicted. The current progress for applications to space and terrestrial thermal management devices, the main topic of the paper, is described in more detail.