DEDouglas W. Evans

Douglas W. Evans

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Douglas W. Evans has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Porohyperviscoelastic Model Simultaneously Predicts Parenchymal Fluid Pressure and Reaction Force in Perfused Liver

    by Emma C. Moran, Smitha Raghunathan, Douglas W. Evans, Nicholas A. Vavalle, Jessica L. Sparks, Tanya LeRoith, Thomas L. Smith

    Porohyperviscoelastic (PHVE) modeling gives a simplified continuum approximation of pore fluid behavior within the parenchyma of liver tissue. This modeling approach is particularly applicable to tissue engineering of artificial livers, where the inherent complexity of the engineered scaffolds prevents the use of computational fluid dynamics. The objectives of this study were to simultaneously predict the experimental parenchymal fluid pressure (PFP) and compression response in a PHVE liver model. The model PFP matched the experimental measurements (318 Pa) to within 1.5%. Linear regression of both phases of compression, ramp, and hold, demonstrated a strong correlation between the model and the experimental reaction force (p<0.5). The ability of this PVE model to accurately predict both fluid and solid behavior is important due to the highly vascularized nature of liver tissue and the mechanosensitivity of liver cells to solid matrix and fluid flow properties.


    • 1 January 2012
      • Vol. 48, 104-11

    Mechanical properties of lower limb dermis following static and cyclic compression.

    by Douglas W Evans, Aaron T Scott, Robert D Teasdall, Beth P Smith, Allyn Howlett, Teresa Connor-Kerr, Jessica L Sparks

    Lower extremity amputations and foot ulcers are complications associated with diabetes, and have been shown to affect diabetic African Americans (AA) three times as often as diabetic non-Hispanic Whites (NHW). Possible causes for the increased risk include ethnic differences in structure and function within the dermis of the lower extremity. Testing this hypothesis requires studying the mechanical properties of skin from different ethnic groups with and without the diagnosis of noninsulin-dependent diabetes. The purpose of this study was to develop a testing method to investigate changes in tensile mechanical properties resulting from static and cyclic compression of dermis harvested from patients undergoing lower extremity amputations. Full thickness dermal samples were obtained from 15 patients undergoing below-knee amputations. Sections of each sample were conditioned with a compressive static pressure (170 mmHg) or cyclic pressures (110-170 mmHg) for 4 hours to elicit collagen bundle remodeling. Skin samples were then tested in tension to obtain sub-plastic stress vs. strain mechanical behavior. Length of the stress-strain toe-region was examined to quantify the effect of collagen bundle remodeling. Toe-region mean lengths were 0.141±0.041, 0.146±0.034, and 0.164±0.064 strains for the control, cyclic, and statically compressed samples respectively (p>.05). These results suggest that the preconditioning regimes did not produce sufficient collagen remodeling to affect the tensile properties of full-thickness dermis. Future work will examine histology from each specimen to identify microstructural features associated with this trend.


    • 1 January 2012
      • Vol. 48, 303-9

    Evaluation of parenchymal fluid pressure in native and decellularized liver tissue.

    by Emma C Moran, Pedro M Baptista, Douglas W Evans, Shay Soker, Jessica L Sparks

    One strategy for tissue engineering of bioartificial livers is the use of decellularized liver scaffolds, which contain a functional vascular network and intact extracellular matrix components. Due to the known mechanosensitivity of liver cells, particularly the response of hepatocytes to changes in parenchymal fluid pressure (PFP), it is necessary to evaluate the biomechanical environment within decellularized scaffolds. The objective of this study was to characterize the dependence of PFP on perfusion flow rate, in native and decellularized liver. Needle-guided Millar SPR-524 (3.5F) pressure sensors were inserted into liver parenchyma to measure PFP in-situ in rat (n=5) and ex-situ in portal vein-perfused native (n=5) and decellularized (n=7) liver tissue. Average in-situ PFP, measured in the left, central and right lobes, was found to be 2.86±1.04 mmHg. PFP measured in ex-situ liver perfused at 3, 6, 9, and 12 ml/min was found to increase linearly with flow rate. Decellularized liver PFP ranged from 0.68 mmHg at 3ml/min to 2.42 mmHg at 12 ml/min, while native liver ranged from 4.32 – 11.93 mmHg. Results demonstrate that PFP in decellularized scaffolds can be controlled by varying flow rate. These results will be implemented in a poroviscoelastic finite element model of liver perfusion, developed by the authors, to predict PFP distribution in three-dimensional scaffolds for known flow rates. This computationally efficient model can be used to optimize perfusion bioreactor conditions throughout the scaffold, to aid in the engineering of functional liver tissue from a decellularized liver organoid.


    • 1 January 2011
      • Vol. 47, 264-9

    Compression instrument for tissue experiments (cite) at the meso-scale: device validation - biomed 2011.

    by Douglas W Evans, Padma Rajagopalan, Raffaella Devita, Jessica L Sparks

    Liver sinusoidal endothelial cells (LSECs) are the primary site of numerous transport and exchange processes essential for liver function. LSECs rest on a sparse extracellular matrix layer housed in the space of Disse, a 0.5-1LSECs from hepatocytes. To develop bioengineered liver tissue constructs, it is important to understand the mechanical interactions among LSECs, hepatocytes, and the extracellular matrix in the space of Disse. Currently the mechanical properties of space of Disse matrix are not well understood. The objective of this study was to develop and validate a device for performing mechanical tests at the meso-scale (100nm-100m), to enable novel matrix characterization within the space of Disse. The device utilizes a glass micro-spherical indentor attached to a cantilever made from a fiber optic cable. The 3-axis translation table used to bring the specimen in contact with the indentor and deform the cantilever. A position detector monitors the location of a laser passing through the cantilever and allows for the calculation of subsequent tissue deformation. The design allows micro-newton and nano-newton stress-strain tissue behavior to be quantified. To validate the device accuracy, 11 samples of silicon rubber in two formulations were tested to experimentally confirm their Young's moduli. Prior macroscopic unconfined compression tests determined the formulations of EcoFlex030 (n-6) and EcoFlex010 (n-5) to posses Young's moduli of 92.67+-6.22 and 43.10+-3.29 kPa respectively. Optical measurements taken utilizing CITE's position control and fiber optic cantilever found the moduli to be 106.4 kPa and 47.82 kPa.