MPMohamad Parnianpour

Mohamad Parnianpour

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohamad Parnianpour has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Musculoskeletal injury risk assessment and intervention at a car manufacturer using various ergonomics and biomechanical tools

    by Hamed Nazemi, Mohammad Javad Salmani, Fatemeh Sabokroozroozbahani, Yashar Ebadi, Fadi Fathallah, Mohammad Parnianpour, Navid Arjmand

    Background: Musculoskeletal injuries are common diseases among workers causing a substantial economic burden on society. Therefore, assessment of musculoskeletal injury risks during occupational activities is essential for the design of subsequent effective interventions and management programs. Methods: Risk of three occupational activities performed by one worker in a shot-peening station of a car manufacturing company has been investigated using several biomechanical (i.e., musculoskeletal models such as HCBCF, Regression models, 3DSSPP and AnyBody) and ergonomics (e.g., Washington State tables, WISHA, NIOSH, MAC, Snook’s Table, ManTRA, QEC, OWAS, REBA, and RULA) risk assessment tools. The worker’s activities involved manual material handling of gearbox shafts and pushing/pulling of a carrier containing these shafts. Results: Our findings indicated a high risk of musculoskeletal injuries during all activities. Therefore, engineering and administrative interventions were provided. After the interventions, injury risk during pushing and pulling activities was fully managed to a safe zone by using overhead cranes. The lifting task was also rendered within a safe zone through the application of administrative interventions and using an appropriate work table. Conclusion: Comprehensive risk assessments by biomechanical and ergonomic tools, managed risks to safe levels, and load dynamics effect in risk assessments were considered.


  • Open Access

    Using a Motion Sensor to Categorize Nonspecific Low Back Pain Patients: A Machine Learning Approach

    by Masoud Abdollahi, Sajad Ashouri, Mohsen Abedi, Nasibeh Azadeh-Fard, Mohamad Parnianpour, Kinda Khalaf, Ehsan Rashedi

    Nonspecific low back pain (NSLBP) constitutes a critical health challenge that impacts millions of people worldwide with devastating health and socioeconomic consequences. In today’s clinical settings, practitioners continue to follow conventional guidelines to categorize NSLBP patients based on subjective approaches, such as the STarT Back Screening Tool (SBST). This study aimed to develop a sensor-based machine learning model to classify NSLBP patients into different subgroups according to quantitative kinematic data, i.e., trunk motion and balance-related measures, in conjunction with STarT output. Specifically, inertial measurement units (IMU) were attached to the trunks of ninety-four patients while they performed repetitive trunk flexion/extension movements on a balance board at self-selected pace. Machine learning algorithms (support vector machine (SVM) and multi-layer perceptron (MLP)) were implemented for model development, and SBST results were used as ground truth. The results demonstrated that kinematic data could successfully be used to categorize patients into two main groups: high vs. low-medium risk. Accuracy levels of ~75% and 60% were achieved for SVM and MLP, respectively. Additionally, among a range of variables detailed herein, time-scaled IMU signals yielded the highest accuracy levels (i.e., ~75%). Our findings support the improvement and use of wearable systems in developing diagnostic and prognostic tools for various healthcare applications. This can facilitate development of an improved, cost-effective quantitative NSLBP assessment tool in clinical and home settings towards effective personalized rehabilitation.


  • Open Access

    A Practical Sensor-Based Methodology for the Quantitative Assessment and Classification of Chronic Non Specific Low Back Patients (NSLBP) in Clinical Settings

    by Mehrdad Davoudi, Seyyed Mohammadreza Shokouhyan, Mohsen Abedi, Narges Meftahi, Atefeh Rahimi, Ehsan Rashedi, Maryam Hoviattalab, Roya Narimani, Mohamad Parnianpour, Kinda Khalaf

    The successful clinical application of patient-specific personalized medicine for the management of low back patients remains elusive. This study aimed to classify chronic nonspecific low back pain (NSLBP) patients using our previously developed and validated wearable inertial sensor (SHARIF-HMIS) for the assessment of trunk kinematic parameters. One hundred NSLBP patients consented to perform repetitive flexural movements in five different planes of motion (PLM): 0° in the sagittal plane, as well as 15° and 30° lateral rotation to the right and left, respectively. They were divided into three subgroups based on the STarT Back Screening Tool. The sensor was placed on the trunk of each patient. An ANOVA mixed model was conducted on the maximum and average angular velocity, linear acceleration and maximum jerk, respectively. The effect of the three-way interaction of Subgroup by direction by PLM on the mean trunk acceleration was significant. Subgrouping by STarT had no main effect on the kinematic indices in the sagittal plane, although significant effects were observed in the asymmetric directions. A significant difference was also identified during pre-rotation in the transverse plane, where the velocity and acceleration decreased while the jerk increased with increasing asymmetry. The acceleration during trunk flexion was significantly higher than that during extension, in contrast to the velocity, which was higher in extension. A Linear Discriminant Analysis, utilized for classification purposes, demonstrated that 51% of the total performance classifying the three STarT subgroups (65% for high risk) occurred at a position of 15° of rotation to the right during extension. Greater discrimination (67%) was obtained in the classification of the high risk vs. low-medium risk. This study provided a smart “sensor-based” practical methodology for quantitatively assessing and classifying NSLBP patients in clinical settings. The outcomes may also be utilized by leveraging cost-effective inertial sensors, already available in today’s smartphones, as objective tools for various health applications towards personalized precision medicine.


  • Sharif-Human movement instrumentation system (SHARIF-HMIS): Development and validation

    by Mohammad Iman Mokhlespour Esfahani, Ali Akbari, Omid Zobeiri, Ehsan Rashedi, Mohamad Parnianpour

    The interest in wearable systems among the biomedical engineering and clinical community continues to escalate as technical refinements enhance their potential use for both indoor and outdoor applications. For example, an important wearable technology known as a microelectromechanical system (MEMS) is demonstrating promising applications in the area of biomedical engineering. Accordingly, this study was designed to investigate the Sharif-Human Movement Instrumentation System (SHARIF-HMIS), consisting of inertial measurement units (IMUs), stretchable clothing, and a data logger-all of which can be used outside the controlled environment of a laboratory, thus enhancing its overall utility. This system is lightweight, portable, able to be deliver data for almost 10 h, and features a new data-fusion algorithm using the Kalman filter with an adaptive approach. In specific terms, the data from the system's gyroscope, accelerometer, and magnetometer sensors can be combined to estimate total-body orientation; additionally, the noise level of these sensors can be changed to accommodate faster motions as well as magnetic disturbances. These variations can be incorporated within the extended Kalman filter by changing the parameters of the filter adaptively. In specific terms, the system's interface was developed to acquire data from eighteen IMUs located on the body to collect kinematic data associated with human motion. Meanwhile, a validation test involving one subject performing different shoulder motions was designed to compare data captured by SHARIF-HMIS and the VICON motion-capture system. This validation test demonstrated correlation values of >0.9. Results also confirmed that the output accuracy of the new system's sensor was <0.55, 1.5 and 3.5° for roll, pitch, and yaw directions, respectively. In summary, SHARIF-HMIS successfully collected kinematic data for specific human movements, which has promising implications for a range of sporting, biomedical, and healthcare-related applications.


  • Open Access

    Trunk Motion System (TMS) Using Printed Body Worn Sensor (BWS) via Data Fusion Approach

    by Mohammad Iman Mokhlespour Esfahani, Omid Zobeiri, Behzad Moshiri, Roya Narimani, Mohammad Mehravar, Ehsan Rashedi, Mohamad Parnianpour

    Human movement analysis is an important part of biomechanics and rehabilitation, for which many measurement systems are introduced. Among these, wearable devices have substantial biomedical applications, primarily since they can be implemented both in indoor and outdoor applications. In this study, a Trunk Motion System (TMS) using printed Body-Worn Sensors (BWS) is designed and developed. TMS can measure three-dimensional (3D) trunk motions, is lightweight, and is a portable and non-invasive system. After the recognition of sensor locations, twelve BWSs were printed on stretchable clothing with the purpose of measuring the 3D trunk movements. To integrate BWSs data, a neural network data fusion algorithm was used. The outcome of this algorithm along with the actual 3D anatomical movements (obtained by Qualisys system) were used to calibrate the TMS. Three healthy participants with different physical characteristics participated in the calibration tests. Seven different tasks (each repeated three times) were performed, involving five planar, and two multiplanar movements. Results showed that the accuracy of TMS system was less than 1.0°, 0.8°, 0.6°, 0.8°, 0.9°, and 1.3° for flexion/extension, left/right lateral bending, left/right axial rotation, and multi-planar motions, respectively. In addition, the accuracy of TMS for the identified movement was less than 2.7°. TMS, developed to monitor and measure the trunk orientations, can have diverse applications in clinical, biomechanical, and ergonomic studies to prevent musculoskeletal injuries, and to determine the impact of interventions.


  • Goal equivalent manifold analysis of task performance in non-specific LBP and healthy subjects during repetitive trunk movement: Effect of load, velocity, symmetry

    by Mahshid Chehrehrazi, Mohammad Ali Sanjari, Hamid Reza Mokhtarinia, Ali Ashraf Jamshidi, Nader Maroufi, Mohamad Parnianpour