SUSteffen Ulmer

Steffen Ulmer

*This is an algorithmically generated author record based on publicly available information.

Steffen Ulmer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Boris Heinz

    Technische Universität Berlin, Germany

    1 shared publication
  • Christian Weber

    CSP Services GmbH, Office Spain: Paseo de Almería 73, 2, 04007 Almería, Spain

    1 shared publication
  • Christoph Prahl

    German Aerospace Center (DLR), Institute of Technical Thermodynamics, Solar Research, Plataforma Solar de Almería, Ctra. de Senés s/n km 4, Apartado 39, 04200 Tabernas, Spain

    1 shared publication
  • Eckhard Lüpfert

    Institute of Technical Thermodynamics, Solar Research, German Aerospace Center (DLR), 51170 Köln, Germany

    1 shared publication
  • Klaus Pottler

    Plataforma Solar de Almería (PSA), Institute of Technical Thermodynamics, Solar Research, German Aerospace Center (DLR), 04200 Tabernas, Spain

    1 shared publication
  • Peter Heller

    German Aerospace Center (DLR), Institute of Technical Thermodynamics, Plataforma Solar de Almería (PSA), 04200 Tabernas, Spain

    1 shared publication

Latest Publications

  • Validation of Two Optical Measurement Methods for the Qualification of the Shape Accuracy of Mirror Panels for Concentrating Solar Systems

    by Tobias März, Christoph Prahl, Steffen Ulmer, Stefan Wilbert, Christian Weber

    The solar field is the major cost component of a solar thermal power plant and the optical quality of the concentrators has a significant impact on the field efficiency and thus on the performance of the power plant. Measuring slope deviations in the parabolic shape of the mirror panels in the accuracy and resolution required for these applications is a challenge as it is not required with the same characteristics in other industries. Photogrammetry and deflectometry are the two optical measurement methods that are typically used to measure this shape accuracy of mirror panels used in CSP applications. They have been compared and validated by measuring a typical mirror panel under optimal conditions. Additionally, a flat water surface has been measured as an absolute reference object using deflectometry. The remaining deviations between the results of both methods and to the reference object are discussed and possible sources of errors during the measurement are identified. A detailed error analysis is conducted for both methods and compared to the experimental findings. The results show that both methods allow for surface slope measurement with the necessary accuracy for present CSP applications and that among the two, deflectometry exhibits advantages in speed, measurement accuracy, and spatial resolution. However, for obtaining correct results several sources of errors have to be addressed appropriately during measurement and postprocessing.


  • Slope Error Measurements of Parabolic Troughs Using the Reflected Image of the Absorber Tube

    by Steffen Ulmer, Boris Heinz, Klaus Pottler, Eckhard Lüpfert

    A new and fast method for optically measuring the reflector slope of parabolic troughs with high accuracy has been developed. It uses the reflection of the absorber tube in the concentrator, as seen from some distance, and is therefore called “absorber reflection method.” A digital camera is placed at a distant observation point perpendicular to the trough axis with the concentrator orientated toward it. Then, a set of pictures from the absorber tube reflection is taken with slightly different tilt angles of the concentrator. A specially developed image analysis algorithm detects the edges of the absorber tube in the reflected images. This information, along with the geometric relationship between the components, the relative collector tilt angles, and the known approximately parabolic shape of the concentrator, is used to calculate the slopes perpendicular to the trough axis. Measurement results of a EuroTrough segment of four facets are presented and verified with results from a reference measurement using high-resolution close-range photogrammetry. The results show good agreement in statistical values as well as in local values of the reflector slope. Compared to the existing photogrammetric method, the new technique reduces drastically the time measurement.


  • Slope Measurements of Parabolic Dish Concentrators Using Color-Coded Targets

    by Steffen Ulmer, Peter Heller, Wolfgang Reinalter

    A new fast and highly accurate method for measuring the slope errors of parabolic dish concentrators has been developed. This method uses a flat target with colored stripes placed close to the focal plane of the concentrator and a digital camera located at an observation point on the optical axis at some distance from it. A specially developed image analysis algorithm detects the different colors of the images of the reflection of the target in the concentrator and assigns them their known position on the color target. This information, along with the geometry of the measurement setup and the theoretical parabolic shape of the concentrator, is used to calculate the normal vectors of the concentrator surface. From these normal vectors, the radial and tangential slopes can be calculated and compared to the design values of the concentrator. The resulting slope errors not only give the total concentrator error for general characterization of the dish but also indicate systematic errors from fabrication and installation with a high spatial resolution. In order to verify the quality of the results obtained, a ray-tracing code was developed that calculates the flux distribution on planes perpendicular to the optical axis. Measured slope errors of a 8.5m dish concentrator are presented and the calculated flux distributions are compared to measured flux distributions. The comparison shows excellent agreement in the flux distribution on the absorber plane. This verifies the promising potential of this fast and highly precise new method for measuring imperfections in dish concentrator shape.