Andriy Andreykiv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andriy Andreykiv has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Fred van Keulen
Department of Precision and Microsystems Engineering Delft University of Technology Delft The Netherlands
2 shared publications P. J. Prendergast
Trinity Centre for Bioengineering, School of Engineering, Trinity College, Dublin, Ireland
2 shared publicationsDaniel J. Rixen
Department of Precision and Microsystems Engineering, Faculty of 3ME, Delft University of Technology, Mekelweg 2, 2628CD, Delft, The Netherlands
1 shared publication
Latest Publications
- 8 June 2009
- Published by Wiley in International Journal for Numerical Methods in Engineering
- Vol. 80 (4) , 478-506
Numerical modelling of electromechanical coupling using fictitious domain and level set methods
- 8 June 2009
- Published by Wiley in International Journal for Numerical Methods in Engineering
- Vol. 80 (4) , 478-506
Numerical modelling of electromechanical coupling using fictitious domain and level set methods
- 15 September 2008
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 130 (5) , 051015
Computational Mechanobiology to Study the Effect of Surface Geometry on Peri-Implant Tissue Differentiation
The geometry of an implant surface to best promote osseointegration has been the subject of several experimental studies, with porous beads and woven mesh surfaces being among the options available. Furthermore, it is unlikely that one surface geometry is optimal for all loading conditions. In this paper, a computational method is used to simulate tissue differentiation and osseointegration on a smooth surface, a surface covered with sintered beads (this simulated the experiment (Simmons, C., and Pilliar, R., 2000, Biomechanical Study of Early Tissue Formation Around Bone-Interface Implants: The Effects of Implant Surface Geometry,” Bone Engineering, J. E. Davies, ed., Emsquared, Chap. A, pp. 369–379) and established that the method gives realistic results) and a surface covered by porous tantalum. The computational method assumes differentiation of mesenchymal stem cells in response to fluid flow and shear strain and models cell migration and proliferation as continuum processes. The results of the simulation show a higher rate of bone ingrowth into the surfaces with porous coatings as compared with the smooth surface. It is also shown that a thicker interface does not increase the chance of fixation failure.
- 15 September 2008
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 130 (5) , 051015
Computational Mechanobiology to Study the Effect of Surface Geometry on Peri-Implant Tissue Differentiation
The geometry of an implant surface to best promote osseointegration has been the subject of several experimental studies, with porous beads and woven mesh surfaces being among the options available. Furthermore, it is unlikely that one surface geometry is optimal for all loading conditions. In this paper, a computational method is used to simulate tissue differentiation and osseointegration on a smooth surface, a surface covered with sintered beads (this simulated the experiment (Simmons, C., and Pilliar, R., 2000, Biomechanical Study of Early Tissue Formation Around Bone-Interface Implants: The Effects of Implant Surface Geometry,” Bone Engineering, J. E. Davies, ed., Emsquared, Chap. A, pp. 369–379) and established that the method gives realistic results) and a surface covered by porous tantalum. The computational method assumes differentiation of mesenchymal stem cells in response to fluid flow and shear strain and models cell migration and proliferation as continuum processes. The results of the simulation show a higher rate of bone ingrowth into the surfaces with porous coatings as compared with the smooth surface. It is also shown that a thicker interface does not increase the chance of fixation failure.
- 31 October 2007
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 7 (6) , 443-461
Simulation of fracture healing incorporating mechanoregulation of tissue differentiation and dispersal/proliferation of cells
Modelling the course of healing of a long bone subjected to loading has been the subject of several investigations. These have succeeded in predicting the differentiation of tissues in the callus in response to a static mechanical load and the diffusion of biological factors. In this paper an approach is presented which includes both mechanoregulation of tissue differentiation and the diffusion and proliferation of cell populations (mesenchymal stem cells, fibroblasts, chondrocytes, and osteoblasts). This is achieved in a three-dimensional poroelastic finite element model which, being poroelastic, can model the effect of the frequency of dynamic loading. Given the number of parameters involved in the simulation, a parameter variation study is reported, and final parameters are selected based on comparison with an in vivo experiment. The model predicts that asymmetric loading creates an asymmetric distribution of tissues in the callus, but only for high bending moments. Furthermore the frequency of loading is predicted to have an effect. In conclusion, a numerical algorithm is presented incorporating both mechanoregulation and evolution of cell populations, and it proves capable of predicting realistic difference in bone healing in a 3D fracture callus.
- 31 October 2007
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 7 (6) , 443-461
Simulation of fracture healing incorporating mechanoregulation of tissue differentiation and dispersal/proliferation of cells
Modelling the course of healing of a long bone subjected to loading has been the subject of several investigations. These have succeeded in predicting the differentiation of tissues in the callus in response to a static mechanical load and the diffusion of biological factors. In this paper an approach is presented which includes both mechanoregulation of tissue differentiation and the diffusion and proliferation of cell populations (mesenchymal stem cells, fibroblasts, chondrocytes, and osteoblasts). This is achieved in a three-dimensional poroelastic finite element model which, being poroelastic, can model the effect of the frequency of dynamic loading. Given the number of parameters involved in the simulation, a parameter variation study is reported, and final parameters are selected based on comparison with an in vivo experiment. The model predicts that asymmetric loading creates an asymmetric distribution of tissues in the callus, but only for high bending moments. Furthermore the frequency of loading is predicted to have an effect. In conclusion, a numerical algorithm is presented incorporating both mechanoregulation and evolution of cell populations, and it proves capable of predicting realistic difference in bone healing in a 3D fracture callus.