AUAndreas Ulrich

Andreas Ulrich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andreas Ulrich has a total of 48 co-authors. Here are the top co-authors by number of shared publications:

  • J. Wieser

    Excitech GmbH Branterei 33 26419 Schortens

    12 shared publications
  • T. Heindl

    Physik-Department Technische Universität München E12 James-Franck-Str. 1 D-85748 Garching Germany

    10 shared publications
  • W. Potzel

    Physik-Department Technische Universtität München D-85748 Garching Germany

    10 shared publications
  • A. Neumeier

    Physik-Department Technische Universität München E15 James-Franck-Str. 1 D-85748 Garching Germany

    9 shared publications
  • L. Oberauer

    Physik-Department Technische Universität München E15 James-Franck-Str. 1 D-85748 Garching Germany

    9 shared publications
  • T. Dandl

    Physik-Department Technische Universität München E12 James-Franck-Str. 1 D-85748 Garching Germany

    9 shared publications

Latest Publications

  • Open Access

    Light emission processes in the context of optical beam profile monitors

    by Raphael Hampf, Jochen Wieser, Andreas Ulrich

    Light emission from gas targets using heavy ion beam excitation is described. Typically 32S beams with ≈90 MeV (2.8 MeV/amu) particle energy were used. This study was performed in context of optical beam profile measurements. Optical transitions from neutral and singly ionized rare gases are suggested for this application. Emission spectra and their line intensities are presented for a wide range of target pressures from about 10–5 to 300 mbar. The effect of secondary electrons on the beam profiles is discussed. A comparison of ion beam and electron beam-induced spectra is shown and interpreted by a semi-quantitative model of the excitation mechanisms. Examples of beam profiles recorded with three different cameras through appropriate optical filters are presented. A comparison of projected profiles and radial profiles obtained by Abel inversion is given. Effective emission cross sections were measured for atomic and ionic lines at various target gas pressures and their pressure dependence interpreted by the excitation mechanisms. Examples of time-resolved measurements of light emission following pulsed excitation support the interpretation of the excitation mechanisms discussed in this overview of ion beam-induced light emission of gas targets. Graphical Abstract


  • Open Access

    Low-Temperature Relative Reflectivity Measurements of Reflective and Scintillating Foils used in Rare Event Searches

    by A. Langenkämper, A. Ulrich, X. Defay, F. V. Feilitzsch, J. -C. Lanfranchi, E. Mondragón, A. Münster, C. Oppenheimer, W. Potzel, S. Roth, et al.

    In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO$_4$ crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO$_4$ target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay ($0\nu\beta\beta$). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no significant change in the reflectivity with temperature for all foils studied.

  • Open Access

    Attenuation measurements of vacuum ultraviolet light in liquid argon revisited

    by A. Neumeier, T. Dandl, A. Himpsl, M. Hofmann, L. Oberauer, W. Potzel, S. Schönert, A. Ulrich

    The attenuation of vacuum ultraviolet light in liquid argon in the context of its application in large liquid noble gas detectors has been studied. Compared to a previous publication several technical issues concerning transmission measurements in general are addressed and several systematic effects were quantitatively measured. Wavelength-resolved transmission measurements have been performed from the vacuum ultraviolet to the near-infrared region. On the current level of sensitivity with a length of the optical path of 11.6 cm, no xenon-related absorption effects could be observed, and pure liquid argon is fully transparent down to the short wavelength cut-off of the experimental setup at 118 nm. A lower limit for the attenuation length of pure liquid argon for its own scintillation light has been estimated to be 1.10 m based on a very conservative approach.

  • Open Access

    Attenuation of vacuum ultraviolet light in pure and xenon-doped liquid argon - an approach to an assignment of the near-infrared emission from the mixture

    by A. Neumeier, T. Dandl, A. Himpsl, L. Oberauer, W. Potzel, S. Schönert, A. Ulrich

    Results of transmission experiments of vacuum ultraviolet light through a 11.6 cm long cell filled with pure and xenon-doped liquid argon are described. Pure liquid argon shows no attenuation down to the experimental short-wavelength cut-off at 118nm. Based on a conservative approach, a lower limit of 1.10 m for the attenuation length of its own scintillation light could be derived. Adding xenon to liquid argon at concentrations on the order of parts per million leads to strong xenon-related absorption features which are used for a tentative assignment of the recently found near-infrared emission observed in electron-beam excited liquid argon-xenon mixtures. Two of the three absorption features can be explained by perturbed xenon transitions and the third one by a trapped exciton (Wannier-Mott) impurity state. A calibration curve connecting the equivalent width of the absorption line at 140 nm with xenon concentration is provided.

  • Open Access

    Attenuation of vacuum ultraviolet light in liquid argon

    by A. Neumeier, M. Hofmann, L. Oberauer, W. Potzel, S. Schönert, T. Dandl, T. Heindl, A. Ulrich, J. Wieser

    The transmission of liquid argon has been measured, wavelength resolved, for a wavelength interval from 118 to 250 nm. The wavelength dependent attenuation length is presented for pure argon. It is shown that no universal wavelength independent attenuation length can be assigned to liquid argon for its own fluorescence light due to the interplay between the wavelength dependent emission and absorption. A decreasing transmission is observed below 130 nm in both chemically cleaned and distilled liquid argon and assigned to absorption by the analogue of the first argon excimer continuum. For not perfectly cleaned argon a strong influence of impurities on the transmission is observed. Two strong absorption bands at 126.5 and 141.0 nm with approximately 2 and 4 nm width, respectively, are assigned to traces of xenon in argon. A broad absorption region below 180 nm is found for unpurified argon and tentatively attributed to the presence of water in the argon sample.

  • Open Access

    Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe Mixtures

    by A. Neumeier, T. Dandl, T. Heindl, A. Himpsl, L. Oberauer, W. Potzel, S. Roth, S. Schönert, J. Wieser, A. Ulrich

    Vacuum ultraviolet light emission from xenon-doped liquid argon is described in the context of liquid noble gas particle detectors. Xenon concentrations in liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from the second excimer continuum of argon ($\sim$127 nm) to the second excimer continuum of xenon ($\sim$174 nm) is observed by recording optical emission spectra. The transfer almost saturates at a xenon concentration of $\sim$10 ppm for which, in addition, an intense emission in the infrared at a peak wavelength of 1.17 $\mu$m with (13000$\pm$4000) photons per MeV deposited by electrons had been found. The corresponding value for the VUV emission at a peak wavelength of 174 nm (second excimer continuum of xenon) is determined to be (20000$\pm$6000) photons per MeV electron energy deposited. Under these excitation conditions pure liquid argon emits (22000$\pm$3000) photons per MeV electron energy deposited at a peak wavelength of 127nm. An electron-beam induced emission spectrum for the 10 ppm Ar-Xe liquid mixture ranging from 115 nm to 3.5 $\mu$m is presented. VUV emission spectra from xenon-doped liquid argon with exponentially varied xenon concentrations from 0.1 ppm to 1000 ppm are also shown. Time structure measurements of the light emissions at well-defined wavelength positions in the vacuum ultraviolet as well as in the near-infrared are presented.

  • Open Access

    Intense Infrared Scintillation of Liquid Ar-Xe Mixtures

    by A. Neumeier, T. Dandl, T. Heindl, A. Himpsl, H. Hagn, M. Hofmann, L. Oberauer, W. Potzel, S. Roth, S. Schönert, et al.

    Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been observed using 12 keV electron-beam excitation. The emission peaks at a wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1 $\mu$m. Maximum intensity has been found for a 10 ppm xenon admixture in liquid argon. The conversion efficiency of electron beam-power to IR-light is about 1% (10000 photons per MeV electron energy deposited). A possible application of this intense IR emission for a new particle discrimination concept in liquid noble gas detectors is discussed. No light emission was found for perfectly purified liquid argon in the wavelength range from 0.5 to 3.5 $\mu$m on the current level of sensitivity.

  • Open Access

    Ion-beam excitation of liquid argon

    by M. Hofmann, T. Dandl, T. Heindl, A. Neumeier, L. Oberauer, W. Potzel, S. Roth, S. Schönert, J. Wieser, A. Ulrich

    The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using our values for the singlet-to-triplet ratio down to low energies deposited a discrimination threshold between incident protons and sulfur ions as low as $\sim$2.5 keV seems possible, which represents the principle limit for the discrimination of these two species in liquid argon.

  • Intense vacuum ultraviolet and infrared scintillation of liquid Ar-Xe mixtures

    by A. Neumeier, T. Dandl, T. Heindl, A. Himpsl, L. Oberauer, W. Potzel, S. Roth, S. Schönert, J. Wieser, A. Ulrich