F. A. Bykovskii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
F. A. Bykovskii has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
E. F. Vedernikov
Lavrentyev Institute of Hydrodynamics, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
20 shared publications- Sergey A. Zhdan
Lavrentyev Institute of Hydrodynamics, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
18 shared publications Yu. A. Zholobov
Novosibirsk State University
5 shared publications- Alexander N. Samsonov
Russian Academy of Sciences
4 shared publications S. A. Zhdan
Lavrentyev Institute of Hydrodynamics, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
4 shared publicationsE F Vedernikov
Lavrentyev Institute of Hydrodynamics SB RAS, Lavrentyev Prosp. 15, 630090, Novosibirsk, Russia
3 shared publications
Latest Publications
- 1 April 2024
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 60 (2) , 193-205
Detonation Burning of a Kerosene–Air Mixture in a Radial Vortex Chamber with Geometry Variations at the Entrance and Exit
Regimes of detonation burning of a two-phase mixture consisting of TS-1 aviation kerosene and air in a radial vortex chamber 500 mm in diameter with exhaustion toward the center and geometry variations at the combustor entrance and exit are obtained and studied. Air is injected into the combustor through a vortex injector, and kerosene bubbled with air is injected through oppositely directed channels. Optical registration of the process is performed through transparent windows in the combustor by a high-speed camera with a frequency of 420 000 fps. The flow pattern observed in the combustor with free exhaustion and an expanding nozzle is continuous spin detonation with one detonation wave rotating with a velocity of 1.68–2.17 km/s close to the Chapman–Jouguet detonation velocity or pulsed detonation with radial waves with a frequency of 0.14–0.26 kHz. Mounting of radial partitions yields pulsed detonation or combustion. In continuous spin detonation, the air flow rate is 3.6–11.7 kg/s, the kerosene flow rate is 0.2–0.77 kg/s, and the equivalence ratio varies from 0.63 to 2.5.
- 1 April 2024
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 60 (2) , 193-205
Detonation Burning of a Kerosene–Air Mixture in a Radial Vortex Chamber with Geometry Variations at the Entrance and Exit
Regimes of detonation burning of a two-phase mixture consisting of TS-1 aviation kerosene and air in a radial vortex chamber 500 mm in diameter with exhaustion toward the center and geometry variations at the combustor entrance and exit are obtained and studied. Air is injected into the combustor through a vortex injector, and kerosene bubbled with air is injected through oppositely directed channels. Optical registration of the process is performed through transparent windows in the combustor by a high-speed camera with a frequency of 420 000 fps. The flow pattern observed in the combustor with free exhaustion and an expanding nozzle is continuous spin detonation with one detonation wave rotating with a velocity of 1.68–2.17 km/s close to the Chapman–Jouguet detonation velocity or pulsed detonation with radial waves with a frequency of 0.14–0.26 kHz. Mounting of radial partitions yields pulsed detonation or combustion. In continuous spin detonation, the air flow rate is 3.6–11.7 kg/s, the kerosene flow rate is 0.2–0.77 kg/s, and the equivalence ratio varies from 0.63 to 2.5.
- 1 February 2022
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 58 (1) , 34-45
Continuous Spin Detonation of the Kerosene–Air Mixture in a Flow-Type Radial Vortex Combustor 500 mm in Diameter
Regimes of detonation burning of TS-1 aviation kerosene in an air flow in a flow-type radial vortex combustor 500 mm in diameter with exhaustion toward the center are obtained. The parameters varied in experiments are the diameter of the combustor exit cross section (from 250 to 125 mm) and the shape of one of the combustor walls. The air flow rate in detonation burning regimes is 5.23–23.85 kg/s, and the kerosene flow rate is 0.49–1.2 kg/s. The fuel-to-air equivalence ratio is varied in the interval from 0.58 to 2.24. Kerosene is bubbled with air before its injection into the combustor. Pulsed detonation with radial waves and continuous spin detonation with one rotating detonation wave with a velocity close to the Chapman–Jouguet detonation velocity are observed. The structure of detonation waves and the flow in their vicinity display no principal differences from those observed previously in a plane–radial combustor with a smaller diameter (204 mm). A strong effect of detonation waves in the combustor on the air and kerosene injection systems is detected. Centrifugal forces acting on the mixture flow and detonation products are enhanced as the combustor exit diameter decreases (as the combustor length increases). For identical specific flow rates of kerosene–air mixtures, the pressure near the cylindrical surface of the combustor in idle runs is found to be higher than that in the case of detonation.
- 1 February 2022
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 58 (1) , 34-45
Continuous Spin Detonation of the Kerosene–Air Mixture in a Flow-Type Radial Vortex Combustor 500 mm in Diameter
Regimes of detonation burning of TS-1 aviation kerosene in an air flow in a flow-type radial vortex combustor 500 mm in diameter with exhaustion toward the center are obtained. The parameters varied in experiments are the diameter of the combustor exit cross section (from 250 to 125 mm) and the shape of one of the combustor walls. The air flow rate in detonation burning regimes is 5.23–23.85 kg/s, and the kerosene flow rate is 0.49–1.2 kg/s. The fuel-to-air equivalence ratio is varied in the interval from 0.58 to 2.24. Kerosene is bubbled with air before its injection into the combustor. Pulsed detonation with radial waves and continuous spin detonation with one rotating detonation wave with a velocity close to the Chapman–Jouguet detonation velocity are observed. The structure of detonation waves and the flow in their vicinity display no principal differences from those observed previously in a plane–radial combustor with a smaller diameter (204 mm). A strong effect of detonation waves in the combustor on the air and kerosene injection systems is detected. Centrifugal forces acting on the mixture flow and detonation products are enhanced as the combustor exit diameter decreases (as the combustor length increases). For identical specific flow rates of kerosene–air mixtures, the pressure near the cylindrical surface of the combustor in idle runs is found to be higher than that in the case of detonation.
- 1 November 2020
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 56 (6) , 682-690
Continuous Detonation of a Mixture of Gaseous Hydrogen and Liquid Oxygen in a Plane–Radial Combustor with Exhaustion Toward the Periphery
Regimes of continuous spin detonation and continuous multifront detonation of a gas–droplet mixture of gaseous hydrogen and liquid oxygen in a plane–radial combustor (internal diameter of 100 mm and external diameter of 300 or 200 mm) with exhaustion toward the periphery are obtained for the first time. The detonation front height of the gas–droplet mixture is greater than that of the gas mixture, which is caused by the critical size of detonation existence. Centrifugal forces acting on the products behind the detonation wave front favor faster filling of the plane–radial combustor with the fresh mixture and increase the detonation front height.
- 1 November 2020
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 56 (6) , 682-690
Continuous Detonation of a Mixture of Gaseous Hydrogen and Liquid Oxygen in a Plane–Radial Combustor with Exhaustion Toward the Periphery
Regimes of continuous spin detonation and continuous multifront detonation of a gas–droplet mixture of gaseous hydrogen and liquid oxygen in a plane–radial combustor (internal diameter of 100 mm and external diameter of 300 or 200 mm) with exhaustion toward the periphery are obtained for the first time. The detonation front height of the gas–droplet mixture is greater than that of the gas mixture, which is caused by the critical size of detonation existence. Centrifugal forces acting on the products behind the detonation wave front favor faster filling of the plane–radial combustor with the fresh mixture and increase the detonation front height.
- Open Access
- 1 November 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1128 (1) , 012062
Continuous spin detonation of methane/hydrogen-air mixtures with additional injection of air to combustion products
Results of experimental investigations in a flow-type annular cylindrical combustor with an outer diameter dc = 503 mm are reported. The influence of air addition to products of continuous spin detonation of a CH4 + 8H2 - air mixture on detonation wave parameters, pressures in the combustor, and specific impulse is studied. The range of existence of continuous spin detonation in terms of the specific flow rate of the mixture through the combustor cross section is extended to 1360 kg/(sm2), whereas the equivalence ratio is reduced to ∑ = 0.4. It is shown that addition of air to detonation products up to the level of the air flow rate in the main injection system increases the velocity of continuous spin detonation, pressure in the combustor, and thrust, whereas the specific flow rate of the fuel decreases.
- 1 November 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1128 (1) , 012062
Open AccessContinuous spin detonation of methane/hydrogen-air mixtures with additional injection of air to combustion products
Results of experimental investigations in a flow-type annular cylindrical combustor with an outer diameter dc = 503 mm are reported. The influence of air addition to products of continuous spin detonation of a CH4 + 8H2 - air mixture on detonation wave parameters, pressures in the combustor, and specific impulse is studied. The range of existence of continuous spin detonation in terms of the specific flow rate of the mixture through the combustor cross section is extended to 1360 kg/(sm2), whereas the equivalence ratio is reduced to ∑ = 0.4. It is shown that addition of air to detonation products up to the level of the air flow rate in the main injection system increases the velocity of continuous spin detonation, pressure in the combustor, and thrust, whereas the specific flow rate of the fuel decreases.
- Open Access
- 1 November 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1128 (1) , 012075
Detonation of a hydrogen-oxygen gas mixture in a plane-radial combustor with exhaustion toward the periphery in the regime of oxygen ejection
- 1 November 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1128 (1) , 012075
Open AccessDetonation of a hydrogen-oxygen gas mixture in a plane-radial combustor with exhaustion toward the periphery in the regime of oxygen ejection
- Open Access
- 27 September 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 899 (4) , 042001
Continuous spin detonation of a syngas-air mixture in a plane-radial vortex combustor
Continuous spin detonation in syngas-air mixtures with three different syngas compositions [CO]/[H2] = 1/3, 1/2, and 1/1 is experimentally studied in a flow-type radial vortex combustor 500 mm in diameter. It is found that all these mixtures with three syngas compositions can be effectively burned in air in the detonation regime. Transverse detonation waves of identical structure are detected. The limits of existence of continuous detonation in terms of the specific flow rates of the mixtures (minimum values) are determined.
- 27 September 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 899 (4) , 042001
Open AccessContinuous spin detonation of a syngas-air mixture in a plane-radial vortex combustor
Continuous spin detonation in syngas-air mixtures with three different syngas compositions [CO]/[H2] = 1/3, 1/2, and 1/1 is experimentally studied in a flow-type radial vortex combustor 500 mm in diameter. It is found that all these mixtures with three syngas compositions can be effectively burned in air in the detonation regime. Transverse detonation waves of identical structure are detected. The limits of existence of continuous detonation in terms of the specific flow rates of the mixtures (minimum values) are determined.
- 1 July 2017
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 53 (4) , 453-460
Detonation combustion of lignite with titanium dioxide and water additives in air
The influence of mineral additives (6.2–70%) and water (15–54%) to lignite on the possibility of its burning in an air flow in a continuous detonation regime in a radial vortex combustor 500 mm in diameter is studied. A syngas with a composition CO + 3H2 is used for transporting the coal mixture and for promoting the chemical reaction. It is shown that regimes of continuous spin detonation, conventional combustion, and pulsed combustion may occur depending on the amounts of the mineral (TiO2) added to coal, water, and syngas. The boundaries between the domains of existence of detonation and combustion are determined in the coordinates of the ratio of the syngas flow rate to the rate of consumption of the combustible portion of coal and the mineral component of coal and water. It is seen that the continuous spin detonation regime persists if the mineral additive fraction in the lignite mixture is up to 65% and the water fraction is smaller than 30%. It is also demonstrated that the syngas flow rate should be increased with increasing mineral additive fraction and increasing coal humidity in order to ensure burning of the combustible component of syngas.
- 1 July 2017
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 53 (4) , 453-460
Detonation combustion of lignite with titanium dioxide and water additives in air
The influence of mineral additives (6.2–70%) and water (15–54%) to lignite on the possibility of its burning in an air flow in a continuous detonation regime in a radial vortex combustor 500 mm in diameter is studied. A syngas with a composition CO + 3H2 is used for transporting the coal mixture and for promoting the chemical reaction. It is shown that regimes of continuous spin detonation, conventional combustion, and pulsed combustion may occur depending on the amounts of the mineral (TiO2) added to coal, water, and syngas. The boundaries between the domains of existence of detonation and combustion are determined in the coordinates of the ratio of the syngas flow rate to the rate of consumption of the combustible portion of coal and the mineral component of coal and water. It is seen that the continuous spin detonation regime persists if the mineral additive fraction in the lignite mixture is up to 65% and the water fraction is smaller than 30%. It is also demonstrated that the syngas flow rate should be increased with increasing mineral additive fraction and increasing coal humidity in order to ensure burning of the combustible component of syngas.
- 1 March 2017
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 53 (2) , 187-198
Scaling factor in continuous spin detonation of syngas–air mixtures
Multiwave regimes of continuous spin detonation in syngas–air mixtures in a flow-type annular cylindrical combustor 503 mm in diameter are obtained. Experiments are performed for mixtures of carbon oxide and hydrogen with the ratio of the components equal to 1/3, 1/2, or 1/1. The varied parameters are the flow rates of air and syngas, the ratio of these flow rates, and the combustor length. Scalability of the continuous spin detonation process is demonstrated: at identical values of the specific flow rate of air and the combustor expansion ratio, the number of transverse detonation waves increases with increasing combustor diameter. In the examined ranges of combustor lengths and specific flow rates of air, the frequency of these waves is independent of the combustor length, except for narrow regions where the number of waves (and, correspondingly, the flow regime) changes. The structures of transverse detonation waves in regular regimes are almost identical for all examined syngas compositions. It is shown that detonation can be initiated by a jet of combustion products. The minimum diameters of the detonation chamber for different flow rates of the mixture are estimated.
- 1 March 2017
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 53 (2) , 187-198
Scaling factor in continuous spin detonation of syngas–air mixtures
Multiwave regimes of continuous spin detonation in syngas–air mixtures in a flow-type annular cylindrical combustor 503 mm in diameter are obtained. Experiments are performed for mixtures of carbon oxide and hydrogen with the ratio of the components equal to 1/3, 1/2, or 1/1. The varied parameters are the flow rates of air and syngas, the ratio of these flow rates, and the combustor length. Scalability of the continuous spin detonation process is demonstrated: at identical values of the specific flow rate of air and the combustor expansion ratio, the number of transverse detonation waves increases with increasing combustor diameter. In the examined ranges of combustor lengths and specific flow rates of air, the frequency of these waves is independent of the combustor length, except for narrow regions where the number of waves (and, correspondingly, the flow regime) changes. The structures of transverse detonation waves in regular regimes are almost identical for all examined syngas compositions. It is shown that detonation can be initiated by a jet of combustion products. The minimum diameters of the detonation chamber for different flow rates of the mixture are estimated.
- 1 January 2017
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 53 (1) , 65-73
Pressure measurement by fast-response piezo-electric sensors during continuous spin detonation in the combustor
Pressure profiles in a transverse detonation wave propagating in a plane-radial vortex chamber during continuous spin detonation of a mixture consisting of lignite, syngas, and air are measured by specially designed and fabricated high-frequency pressure sensors based on TsTS-19 piezo-ceramics. Pressure levels in the detonation wave front relative to the mean static pressure are determined. It is demonstrated that these levels decrease toward the combustor center (by a factor of 20 and lower) as the wave intensity (velocity) decreases. Pressure oscillations behind the wave front testify to a complex gas-dynamic pattern of the processes in the wave region. A chemical reaction region is detected behind the wave front; its length is approximately 8% of the period between the waves.
- 1 January 2017
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 53 (1) , 65-73
Pressure measurement by fast-response piezo-electric sensors during continuous spin detonation in the combustor
Pressure profiles in a transverse detonation wave propagating in a plane-radial vortex chamber during continuous spin detonation of a mixture consisting of lignite, syngas, and air are measured by specially designed and fabricated high-frequency pressure sensors based on TsTS-19 piezo-ceramics. Pressure levels in the detonation wave front relative to the mean static pressure are determined. It is demonstrated that these levels decrease toward the combustor center (by a factor of 20 and lower) as the wave intensity (velocity) decreases. Pressure oscillations behind the wave front testify to a complex gas-dynamic pattern of the processes in the wave region. A chemical reaction region is detected behind the wave front; its length is approximately 8% of the period between the waves.
- 1 November 2016
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 52 (6) , 703-712
Detonation burning of anthracite and lignite particles in a flow-type radial combustor
Regimes of continuous spin detonation of anthracite and lignite particles in an air flow in a radial vortex combustor 500 mm in diameter with a constant (along the radius) cross-sectional area are studied. Ground coal with a particle size of 1–12 μm is used. For transporting coal into the combustor and promoting the chemical reaction on the surface of solid particles, hydrogen or syngas is added in the ratio CO/H = 1/1, 1/2, or 1/3. Continuous spin detonation of two-phase mixtures of fine anthracite and lignite particles and air with addition of hydrogen up to 4% of the coal consumption rate is obtained for the first time. The amount of syngas added to coal increases with decreasing fraction of hydrogen in the syngas: 14, 21, and 27% for anthracite and 11, 20, and 29% for lignite at CO/H = 1/3, 1/2, and 1/1, respectively. The structure of detonation waves and the flow in their vicinity are not principally different from those observed previously for long-flame bituminous coal and charcoal. Higher detonation velocities are observed for more energy-intensive coal (anthracite). A higher pressure is obtained near the cylindrical wall of the combustor in cold runs as compared to detonation in the case with identical flow rates of the coal–air mixtures.
- 1 November 2016
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 52 (6) , 703-712
Detonation burning of anthracite and lignite particles in a flow-type radial combustor
Regimes of continuous spin detonation of anthracite and lignite particles in an air flow in a radial vortex combustor 500 mm in diameter with a constant (along the radius) cross-sectional area are studied. Ground coal with a particle size of 1–12 μm is used. For transporting coal into the combustor and promoting the chemical reaction on the surface of solid particles, hydrogen or syngas is added in the ratio CO/H = 1/1, 1/2, or 1/3. Continuous spin detonation of two-phase mixtures of fine anthracite and lignite particles and air with addition of hydrogen up to 4% of the coal consumption rate is obtained for the first time. The amount of syngas added to coal increases with decreasing fraction of hydrogen in the syngas: 14, 21, and 27% for anthracite and 11, 20, and 29% for lignite at CO/H = 1/3, 1/2, and 1/1, respectively. The structure of detonation waves and the flow in their vicinity are not principally different from those observed previously for long-flame bituminous coal and charcoal. Higher detonation velocities are observed for more energy-intensive coal (anthracite). A higher pressure is obtained near the cylindrical wall of the combustor in cold runs as compared to detonation in the case with identical flow rates of the coal–air mixtures.