Li Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Li Song has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Gang Wang
Univ. of Miami, FL (United States)
3 shared publications Oluwaseyi T. Ogunsola
School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, Oklahoma, USA
3 shared publicationsJunjun Hu
School of Computer Science, University of Oklahoma, Norman, OK 73019, USA
2 shared publications- Junke Wang
School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
2 shared publications Meijun Zhu
Department of Mathematics, University of Oklahoma, Norman, OK 73019, USA
2 shared publications- Nurayn Tiamiyu
School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
2 shared publications
Latest Publications
- 3 July 2026
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 32 (6) , 667
Innovative research in the built environment presented at the 2025 ASHRAE Winter Conference
This special issue of Science and Technology for the Built Environment (STBE) presents expanded versions of selected conference papers originally presented at the 2025 ASHRAE Winter Conference in O...
- 3 July 2026
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 32 (6) , 667
Innovative research in the built environment presented at the 2025 ASHRAE Winter Conference
This special issue of Science and Technology for the Built Environment (STBE) presents expanded versions of selected conference papers originally presented at the 2025 ASHRAE Winter Conference in O...
- Open Access
- 8 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (16) , 12113
Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems
An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.
- 8 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (16) , 12113
Open AccessLoose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems
An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.
- Open Access
- 13 June 2023
- Published by MDPI AG in Preprints.org
Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems
An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable frequency drives (VFDs) makes the motor efficiency data published by manufacturers inapplicable, the fan efficiency and drive (belt-motor-VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD-motor-fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency and drive efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then the energy model is identified for an existing VFD-motor-fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD-motor-fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.
- 13 June 2023
- Published by MDPI AG in Preprints.org
Open AccessLoose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems
An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable frequency drives (VFDs) makes the motor efficiency data published by manufacturers inapplicable, the fan efficiency and drive (belt-motor-VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD-motor-fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency and drive efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then the energy model is identified for an existing VFD-motor-fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD-motor-fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.
- 6 May 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (6) , 692-704
Survey of particle production rates from process activities in pharmaceutical and biological cleanrooms
The lack of measurement data on particle generation rates from process activities for companies involved in the life sciences industry, such as pharmaceutical and biotechnology firms, has the potential to undermine cleanroom design, particulate concentration control, and energy efficiency. Based on this situation, this paper surveys the particle production rates from process activities in pharmaceutical and biological cleanrooms using field measurements for the particle sizes of interest (0.3 µm, 0.5 µm, and 1 µm). The measured and collected data were correlated to the surveyed activities to obtain a range of particle generation rates for different cleanroom operations. In terms of the recommended ACH values and measured ACH values, the results indicate that although most cleanrooms operate below the recommended ranges, in most cases they satisfy or exceed the required ISO standard cleanliness levels. In addition, the particle generation rates are process-specific and that suggests process-specific guidelines for different cleanrooms will help engineers, owners and contractors arrive at a better design solution. It is worth mentioning that nonperfect mixing of airflow and particles was observed in several cleanrooms, resulting in large variances in the measurements at different sampling locations. This observation suggests that a correction factor might be needed for the ventilation effectiveness for Class 7 and 8 cleanrooms. Although the determination of the correction factor is beyond the study of this paper, the data presented in this paper are critical to understand the severity of the non-perfect mixing in Class 7 and 8 cleanrooms and thus provides insights on the determination of the correction factor. The research reported in this paper was conducted through the ASHRAE 1399 research project, with a focus on developing scientific cleanroom design guidelines that can assist engineers, owners, and contractors to arrive at appropriately sized and efficient cleanroom systems.
- 6 May 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (6) , 692-704
Survey of particle production rates from process activities in pharmaceutical and biological cleanrooms
The lack of measurement data on particle generation rates from process activities for companies involved in the life sciences industry, such as pharmaceutical and biotechnology firms, has the potential to undermine cleanroom design, particulate concentration control, and energy efficiency. Based on this situation, this paper surveys the particle production rates from process activities in pharmaceutical and biological cleanrooms using field measurements for the particle sizes of interest (0.3 µm, 0.5 µm, and 1 µm). The measured and collected data were correlated to the surveyed activities to obtain a range of particle generation rates for different cleanroom operations. In terms of the recommended ACH values and measured ACH values, the results indicate that although most cleanrooms operate below the recommended ranges, in most cases they satisfy or exceed the required ISO standard cleanliness levels. In addition, the particle generation rates are process-specific and that suggests process-specific guidelines for different cleanrooms will help engineers, owners and contractors arrive at a better design solution. It is worth mentioning that nonperfect mixing of airflow and particles was observed in several cleanrooms, resulting in large variances in the measurements at different sampling locations. This observation suggests that a correction factor might be needed for the ventilation effectiveness for Class 7 and 8 cleanrooms. Although the determination of the correction factor is beyond the study of this paper, the data presented in this paper are critical to understand the severity of the non-perfect mixing in Class 7 and 8 cleanrooms and thus provides insights on the determination of the correction factor. The research reported in this paper was conducted through the ASHRAE 1399 research project, with a focus on developing scientific cleanroom design guidelines that can assist engineers, owners, and contractors to arrive at appropriately sized and efficient cleanroom systems.
- 6 April 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 456-469
Preliminary Tests for an Engineering Approach to Achieve Energy Efficient Airside Economizers without Humidity Sensors
Outdoor air (OA) and return air (RA) humidity measurements are essential to implement combined differential enthalpy/temperature airside economizers at air handling units (AHUs). However, due to the lack of reliable air humidity sensors, economizers are more often disabled or replaced by less-efficient temperature economizers. On the other hand, the OA humidity ratio may be obtained from weather station data and the RA humidity ratio may be correlated with the supply air (SA) temperature under humid OA conditions when enthalpy economizers are applied. With these two hypotheses, the economizers can be readily achieved through an engineering approach without direct humidity measurements at AHUs. The purpose of this paper is to experimentally validate these two hypotheses. The engineering approach is explained first and then experiments are conducted on selected AHUs in three cities, Laramie, WY, Norman, OK and Miami, FL. The experiment results reveal that 1) the OA humidity ratio can be obtained from the weather station data with the standard deviation of 0.0010 kgv/kga (or lbmv/lbma) for dry and moderate humid climates and with the standard deviation of 0.0026 kgv/kga (or lbmv/lbma) for humid climates; and 2) the RA humidity ratio can be correlated to the saturated humidity ratio at the SA temperature with the standard deviation of 0.0005 kgv/kga (or lbmv/lbma) under humid OA conditions.
- 6 April 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 456-469
Preliminary Tests for an Engineering Approach to Achieve Energy Efficient Airside Economizers without Humidity Sensors
Outdoor air (OA) and return air (RA) humidity measurements are essential to implement combined differential enthalpy/temperature airside economizers at air handling units (AHUs). However, due to the lack of reliable air humidity sensors, economizers are more often disabled or replaced by less-efficient temperature economizers. On the other hand, the OA humidity ratio may be obtained from weather station data and the RA humidity ratio may be correlated with the supply air (SA) temperature under humid OA conditions when enthalpy economizers are applied. With these two hypotheses, the economizers can be readily achieved through an engineering approach without direct humidity measurements at AHUs. The purpose of this paper is to experimentally validate these two hypotheses. The engineering approach is explained first and then experiments are conducted on selected AHUs in three cities, Laramie, WY, Norman, OK and Miami, FL. The experiment results reveal that 1) the OA humidity ratio can be obtained from the weather station data with the standard deviation of 0.0010 kgv/kga (or lbmv/lbma) for dry and moderate humid climates and with the standard deviation of 0.0026 kgv/kga (or lbmv/lbma) for humid climates; and 2) the RA humidity ratio can be correlated to the saturated humidity ratio at the SA temperature with the standard deviation of 0.0005 kgv/kga (or lbmv/lbma) under humid OA conditions.
- 28 January 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 22 (3) , 266-280
Analysis of passive thermal storage opportunities for heating system design
Heating and cooling load calculations are critical to size HVAC systems and determine energy use of their operations. The ASHRAE recommended heating load calculation model is most commonly used for heating load calculations. It adopts a simplified approach by considering only steady-state conductive heat transfer. However, due to thermal storage effect, heat generated in daytime may still be stored in buildings and released at a later time. Such assumption leads to significantly over-sized heating systems which are usually accompanied by high initial cost and higher cost of energy use. This study therefore examines the thermal response and passive storage characteristic of heavy construction for typical office building in continental United States. By allowing space air to drift to reasonably lower values, buildings need to be warmed up before being occupied in the morning. The worst case conditions might happen during warm-up or beginning of occupied hours. This article evaluates the optimal size of heating system which satisfies thermal comfort while taking advantage of passive thermal storage. Results show varying downsizing opportunities ranging from 14% to 54% across the United States. These results have the potential of establishing new heating device design standards for certain climate classifications.
- 28 January 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 22 (3) , 266-280
Analysis of passive thermal storage opportunities for heating system design
Heating and cooling load calculations are critical to size HVAC systems and determine energy use of their operations. The ASHRAE recommended heating load calculation model is most commonly used for heating load calculations. It adopts a simplified approach by considering only steady-state conductive heat transfer. However, due to thermal storage effect, heat generated in daytime may still be stored in buildings and released at a later time. Such assumption leads to significantly over-sized heating systems which are usually accompanied by high initial cost and higher cost of energy use. This study therefore examines the thermal response and passive storage characteristic of heavy construction for typical office building in continental United States. By allowing space air to drift to reasonably lower values, buildings need to be warmed up before being occupied in the morning. The worst case conditions might happen during warm-up or beginning of occupied hours. This article evaluates the optimal size of heating system which satisfies thermal comfort while taking advantage of passive thermal storage. Results show varying downsizing opportunities ranging from 14% to 54% across the United States. These results have the potential of establishing new heating device design standards for certain climate classifications.
- 7 August 2014
- Published by Taylor & Francis in HVAC&R Research
- Vol. 20 (6) , 594-605
Restoration of 1–24 hour dry-bulb temperature gaps for use in building performance monitoring and analysis—Part I
Building energy system retrofit and retro-commissioning projects present tremendous opportunities to save energy. Energy consumption in buildings, especially HVAC systems, is significantly impacted by weather conditions. However, short- or long-term climatic data are frequently missing because of data transmission problems, data quality assurance methods, sensor malfunction, or a host of other reasons. These gaps in climatic data continue to provide challenges for HVAC engineers in monitoring and verifying building energy performance. This article examines eight classical approaches that use Linear interpolation, Lagrange interpolation, and Cubic Spline interpolation techniques, and eleven approaches that use two newly developed methods, i.e., Angle-based interpolation and Corr-based interpolation, to restore up to 24 h of missing dry-bulb temperature data in a time series for use in building performance monitoring and analysis. Eleven one-year hourly data sets are used to evaluate the performance of these 19 different methods. Each method is applied to deal with artificial gaps that are generated randomly. In terms of the difference between estimated values and measured values, two types of comparisons are carried out. The first comparison is conducted with three evaluation indices: MAE, RMSE, and STDBIAS. The second comparison is based on the percentage of the total data that can be estimated by an approach within specific error thresholds, including 1°F (0.56°C), 2°F (1.11°C), 3°F (1.67°C), and 5°F (2.78°C), from measured values. The comparison results show that Linear interpolation performs best when filling 1–2 h gaps, Lagrange interpolation (Lag2L2R) outperforms other methods when gaps are 3–8 h long, and the Corr-based interpolation method (Corr1L1R24Avg) is a better technique for filling 9–24 h gaps. This article presents the first part of the research results through the ASHRAE 1413 research project. The second part of the results focuses on methods to filling long-term dry-bulb temperature gaps.
- 7 August 2014
- Published by Taylor & Francis in HVAC&R Research
- Vol. 20 (6) , 594-605
Restoration of 1–24 hour dry-bulb temperature gaps for use in building performance monitoring and analysis—Part I
Building energy system retrofit and retro-commissioning projects present tremendous opportunities to save energy. Energy consumption in buildings, especially HVAC systems, is significantly impacted by weather conditions. However, short- or long-term climatic data are frequently missing because of data transmission problems, data quality assurance methods, sensor malfunction, or a host of other reasons. These gaps in climatic data continue to provide challenges for HVAC engineers in monitoring and verifying building energy performance. This article examines eight classical approaches that use Linear interpolation, Lagrange interpolation, and Cubic Spline interpolation techniques, and eleven approaches that use two newly developed methods, i.e., Angle-based interpolation and Corr-based interpolation, to restore up to 24 h of missing dry-bulb temperature data in a time series for use in building performance monitoring and analysis. Eleven one-year hourly data sets are used to evaluate the performance of these 19 different methods. Each method is applied to deal with artificial gaps that are generated randomly. In terms of the difference between estimated values and measured values, two types of comparisons are carried out. The first comparison is conducted with three evaluation indices: MAE, RMSE, and STDBIAS. The second comparison is based on the percentage of the total data that can be estimated by an approach within specific error thresholds, including 1°F (0.56°C), 2°F (1.11°C), 3°F (1.67°C), and 5°F (2.78°C), from measured values. The comparison results show that Linear interpolation performs best when filling 1–2 h gaps, Lagrange interpolation (Lag2L2R) outperforms other methods when gaps are 3–8 h long, and the Corr-based interpolation method (Corr1L1R24Avg) is a better technique for filling 9–24 h gaps. This article presents the first part of the research results through the ASHRAE 1413 research project. The second part of the results focuses on methods to filling long-term dry-bulb temperature gaps.
- 4 June 2014
- Published by Taylor & Francis in HVAC&R Research
- Vol. 20 (6) , 606-615
Restoration of missing dry-bulb temperature data with long-term gaps (up to 60 days) for use in building performance monitoring and analysis—Part II
The lack of standard procedures for filling climatic data has the potential to undermine design, monitoring, and control efforts aimed at climate-responsive building design, performance monitoring, and energy efficiency. This article addresses the challenge of long-term missing gaps in dry-bulb temperature data by examining three spatial methods, namely the inverse distance weighting (IDW) method, the spatial regression test (SRT) method, and the substitution with best match data (SSBM) method, as well as two temporal methods, namely the temporal regression test (TRT) method and the temporal substitution with best match data (TSBM) method. Using these methods, missing dry-bulb temperature data with long-term gaps, ranging from 1 to 60 days, are restored for use in building performance monitoring and analysis. Three one-year, hourly datasets were used to evaluate the performance of these approaches. Each method was applied to deal with artificial gaps which were generated randomly and represented different seasons of a year. In terms of the difference between estimated values and measured values, three evaluation indices, namely mean absolute error (MAE), root mean square error (RMSE), and standard error of bias (BIASSTD), were utilized. The comparison results show that spatial methods are better than temporal methods. The confidence level of the SRT method was further investigated by applying this method to existing data and missing data, and examining its performance. The results indicate that the uncertainty of the SRT method can be predicted and at least two neighboring stations are recommended when using it. This is the second part of the research results obtained through the ASHRAE 1413 research project (in press) with a focus on introducing gap-filling methods for long-term gaps in dry-bulb temperature.
- 4 June 2014
- Published by Taylor & Francis in HVAC&R Research
- Vol. 20 (6) , 606-615
Restoration of missing dry-bulb temperature data with long-term gaps (up to 60 days) for use in building performance monitoring and analysis—Part II
The lack of standard procedures for filling climatic data has the potential to undermine design, monitoring, and control efforts aimed at climate-responsive building design, performance monitoring, and energy efficiency. This article addresses the challenge of long-term missing gaps in dry-bulb temperature data by examining three spatial methods, namely the inverse distance weighting (IDW) method, the spatial regression test (SRT) method, and the substitution with best match data (SSBM) method, as well as two temporal methods, namely the temporal regression test (TRT) method and the temporal substitution with best match data (TSBM) method. Using these methods, missing dry-bulb temperature data with long-term gaps, ranging from 1 to 60 days, are restored for use in building performance monitoring and analysis. Three one-year, hourly datasets were used to evaluate the performance of these approaches. Each method was applied to deal with artificial gaps which were generated randomly and represented different seasons of a year. In terms of the difference between estimated values and measured values, three evaluation indices, namely mean absolute error (MAE), root mean square error (RMSE), and standard error of bias (BIASSTD), were utilized. The comparison results show that spatial methods are better than temporal methods. The confidence level of the SRT method was further investigated by applying this method to existing data and missing data, and examining its performance. The results indicate that the uncertainty of the SRT method can be predicted and at least two neighboring stations are recommended when using it. This is the second part of the research results obtained through the ASHRAE 1413 research project (in press) with a focus on introducing gap-filling methods for long-term gaps in dry-bulb temperature.
- 4 April 2012
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 134 (3) , 031002
Next-Day Daily Energy Consumption Forecast Model Development and Model Implementation
Thermal storage systems were originally designed to shift on-peak cooling production to off-peak cooling production in order to reduce on-peak electricity demand. Recently, however, the reduction of both on- and off-peak demand is a critical issue. Reduction of on- and off-peak demand can also extend the life span and defer or eliminate the replacement of power transformers. Next day electricity consumption is a critical set point to operate chillers and associated pumps at the appropriate time. In this paper, a data evaluation process using the annual daily average cooling consumption of a building was conducted. Three real-time building load forecasting models were investigated: a first-order autoregressive model (AR(1)), an autogressive integrated moving average model (ARIMA(0,1,0)), and a linear regression model. A comparison of results shows that the AR(1) and ARIMA(0,1,0) models provide superior results to the linear regression model, except that the AR(1) model has a few unacceptable spikes. A complete control algorithm integrated with a corrected AR(1) forecast model for a chiller plant including chillers, thermal storage system, and pumping systems was developed and implemented to verify the feasibility of applying this algorithm in the building automation system. Application results are also introduced in the paper.
- 4 April 2012
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 134 (3) , 031002
Next-Day Daily Energy Consumption Forecast Model Development and Model Implementation
Thermal storage systems were originally designed to shift on-peak cooling production to off-peak cooling production in order to reduce on-peak electricity demand. Recently, however, the reduction of both on- and off-peak demand is a critical issue. Reduction of on- and off-peak demand can also extend the life span and defer or eliminate the replacement of power transformers. Next day electricity consumption is a critical set point to operate chillers and associated pumps at the appropriate time. In this paper, a data evaluation process using the annual daily average cooling consumption of a building was conducted. Three real-time building load forecasting models were investigated: a first-order autoregressive model (AR(1)), an autogressive integrated moving average model (ARIMA(0,1,0)), and a linear regression model. A comparison of results shows that the AR(1) and ARIMA(0,1,0) models provide superior results to the linear regression model, except that the AR(1) model has a few unacceptable spikes. A complete control algorithm integrated with a corrected AR(1) forecast model for a chiller plant including chillers, thermal storage system, and pumping systems was developed and implemented to verify the feasibility of applying this algorithm in the building automation system. Application results are also introduced in the paper.