Latest Publications

  • Heat transfer enhancement in falling liquid films on an array of horizontal tubes with plasma spray porous coating

    by Nikolay I. Pecherkin, Oleg A. Volodin, Mihir K. Das, Aleksandr N. Pavlenko, Andrey I. Kataev, Irina B. Mironova


  • Heat Transfer in a Falling Liquid Film of Freon R21 on an Array of Horizontal Tubes with Modified MAO Coatings

    by N. I. Pecherkin, A. N. Pavlenko, O. A. Volodin

    The paper presents the results of a study of heat transfer in a falling film of freon R21 on a single-row bundle of horizontal tubes made of aluminum alloys with outer diameters of 10 mm and modified oxide porous coatings. The oxide coatings were deposited by micro-arc oxidation (MAO) in phosphate, acid, and silicate-alkaline electrolytes. The surface modification of the MAO coatings consisted in the deposition of copper particles in a solution of copper sulphate. The heat transfer coefficients for the modified MAO coatings were compared with the results for the surface of tubes with base MAO coatings in electrolytes of similar compositions, as well as for a smooth metal tube without coating for Reynolds numbers of the falling film varying from 600 to 1500. Additional surface treatment of the porous ceramic coatings by the deposition of copper particles has led to a significant decrease in the heat transfer coefficients in the falling film compared with the base MAO coatings. The highest enhancement of the heat transfer relative to the case of the smooth tube (of up to 80%) was obtained on the modified MAO coating deposited in the phosphate electrolyte.


  • Effect of Tube Rows on Two-Phase Heat Transfer Characteristics of Water Over Staggered Tube Bundles Under Flow Boiling Mode

    by Subhakanta Moharana, Bibhu Bhusan Sha, Mihir K. Das, Nikolay Ivanovich Pecherkin, Aleksandr Nikolaevich Pavlenko, Oleg Alexandovich Volodin

    Tube bundles are an integral part of the two-phase heat exchangers and are employed in numerous commercial applications. Present research compares two kinds of horizontal staggered tube bundles under upward crossflow boiling to see how tube rows affect the heat transfer coefficient (HTC). The experimental set-up developed houses the tube bundle for temperature measurements and facilities the recording of high-speed images at different operating conditions. The investigation is carried out for heat fluxes of 10-75 kW/m2, mass fluxes of 20-100 kg/m2s, and P/D ratios of 1.25, 1.6, and 1.95, with distilled water as the working fluid. It is observed that both the tube bundle shows an increase in overall heat transfer coefficient (HTC) with an increase in heat flux. However, the 5x3 tube bundle resulted in a greater heat transfer rate as compared to the 2x3 tube bundle due to the bundle effect. Further, both the tube bundles have a diminishing trend of HTC with a rise in mass flux. The rate of rising in HTC was found to decrease with an increase in the number of tube rows in the tube bundle and with an increase in the P/D ratio. Therefore, interestingly it is observed that the increase in bundle average HTC of 5x3 tube bundle is not twice that of 2x3 tube bundle rather it is quite lesser which further deteriorates with an increase in P/D ratio. The data is predicted within 15% using correlation.


  • Open Access

    Combining Microstructured Surface and Mesh Covering for Heat Transfer Enhancement in Falling Films of Refrigerant Mixture

    by Oleg Volodin, Nikolay Pecherkin, Aleksandr Pavlenko

    The article presents the experimental results of combining a basic microstructure with partly closed pores and a mesh covering for heat transfer enhancement at the film flow of a refrigerant mixture. To reveal the effect of the combined structure, heat transfer on a microstructured surface without a covering as well as on a smooth surface with a mesh covering only has been studied. All experimental series were carried out using a binary mixture of R114 and R21 refrigerants. The mixture film flowed down the outer surface of a vertical cylinder in the undeveloped turbulence regime, when the film Reynolds number varied from 400 to 1300. It is shown that a microstructured surface with a fin pitch of 200 μm, fin height of 220 μm, and longitudinal knurling pitch of 160 μm, created by deformational cutting, demonstrates significant heat transfer enhancement: up to four times as compared to a smooth surface. However, adding a mesh covering with an aperture of 220 μm and a wire diameter of 100 μm reduces the intensification. The mesh covering overlaid on a smooth surface also does not provide heat transfer enhancement as compared to the smooth surface itself. The absence or even deterioration of heat transfer enhancement on surfaces with mesh covering can be primarily associated with the low thermal conductivity of the mesh material and shortcomings of the applied method of mesh mounting. The possibility of deteriorating vapor removal due to the incorrect selection of mesh covering parameters was also analyzed. The heat transfer coefficient values obtained for basic microstructured surfaces were compared with the dependencies available in the literature for predicting pool boiling heat transfer on microfinned surfaces.


  • Open Access

    Studying the process of freons mixture separation on a structured packing Sultzer 500X

    by Aleksandr Pavlenko, Vladimir Zhukov, Nikolay Pecherkin, Ekaterina Slesareva, Christo Boyadjiev, Daniela Dzhonova-Atanasova

    Structured packings are widely used in distillation columns to separate various types of mixtures. These packings have an ordered structure, which ensures more uniform conditions for interaction of counter-current flows of liquid and vapor than in the random packings and have a small hydraulic resistance. Nevertheless, in columns with a diameter of more than 0.5 m, formation of large-scale non-uniformity in distribution of liquid and vapor flow parameters over the packing cross-section is observed. In this work, experimental data on formation of large-scale non-uniformity in the temperature field over the cross-section of the Sulzer 500X packing, as well as on the efficiency of mixture separation and the pressure drop across the packing were obtained. The experiments were carried out with separation of R114/R21 freon mixture on a 10-layer structured packing Sulzer 500X with a diameter of 0.6 m and a height of 2.2 m. Experimental data were compared with the results obtained earlier for a structured packing Mellapack 350.Y with a diameter of 0.9 m and a height of 2.1 m. The presented experimental data will be used to construct and verify a new model of mass transfer and efficiency of mixture separation in the large-scale distillation packed columns.


  • Open Access

    Heat transfer in the falling liquid film on an array of horizontal tubes with MAO coating

    by A N Pavlenko, N I Pecherkin, O A Volodin, A I Kataev, I B Mironova

    The paper presents investigation results on heat transfer of falling liquid films of Freon R21 on an array of horizontal tubes with porous Al2O3 coating obtained by the method of microarc oxidation (MAO coating). The microcharacteristics of samples (porosity, thickness, surface roughness) were measured. The results of measuring heat transfer coefficients on the surface of an aluminum tube with a MAO coating and a reference smooth tube were compared. Heat transfer on the surface of the tube with a porous coating was lower than on a smooth reference tube. It was shown that to intensify heat transfer on a surface with a MAO coating, it is necessary to increase the porosity of the coating and decrease its the thermal resistance.


  • Open Access

    Effect of the angle of rotation of structured packing layers on separation efficiency in distillation column

    by A N Pavlenko, N I Pecherkin, V E Zhukov, A D Nazarov, G Meski, P Houghton

    It is well known that a good quality of liquid distribution over the surface of structured packings is crucial for high performance of large diameter columns. The angle of rotation of the packing layers and their number are among the main parameters characterizing the distribution of liquid in a structured packing over the column cross-section and height. This paper presents investigation results on the influence of the rotation angle of structured packing layers on separation efficiency, pressure drop, distribution of local composition of mixture and local liquid flow rate under the packing. The experiments were carried out in distillation column with the internal diameter of 0.9 m on a structured packing with a specific area of 500 m2/m3, and the corrugation angle of packing equal to 45°. The mixture of refrigerants R114 and R21 at the pressure of 3 bar and total reflux was used as the working fluid. The column was packed with 11 packing layers with rotation angles of 20, 45, 70, and 90 degrees. According to experimental results, a decrease in the angle of packing layer rotation from 90 to 20 degrees leads to a decrease in separation efficiency, while the HETP value increases by 10–12%.


  • Open Access

    Mixture separation in distillation column with semicylindrical structured packing

    by N I Pecherkin, A N Pavlenko, V E Zhukov, A D Nazarov, G Meski, P Houghton

    This paper presents investigation results on separation of a binary mixture in distillation columns of semi-cylindrical cross-section with structured packing. The effect of vapor and liquid flow rates, packing height on separation efficiency, pressure drop, distribution of local liquid flow rates, temperature, and mixture composition as under the structured packing so in different positions inside the column was studied experimentally. An increase in the ratio of the molar flow rates of the liquid and vapor phases L/V results in a decrease in the height equivalent to the theoretical plate HETP. Increasing of the height of the structured packing leads to deterioration in the efficiency of the mixture separation. To analyze the effect of the shape of the column cross-section on the separation efficiency, the similar experiments were carried out in a round column. The main regularities in the influence of the structured packing height, ratio of liquid and vapor flow rates, and other operating parameters obtained for the round column are also valid for the column with a semi-cylindrical cross-section.