Biddut Bhattacharjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Biddut Bhattacharjee has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Homayoun Najjaran
University of Victoria
2 shared publications
Latest Publications
- 1 December 2009
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 132 (1) , 014501
Simulation of Droplet Position Control in Digital Microfluidic Systems
Digital microfluidic systems (DMSs) are emerging with high potential to serve as true labs-on-a-chip (LOCs) systems for various chemical and biochemical analyses. Significant research efforts have been devoted toward the design and fabrication of improved LOC systems. Due to design, fabrication, and also runtime uncertainties, feedback control schemes must be incorporated to ensure reliability and accuracy of LOCs for practical use. This paper introduces the basics of the control analysis and design of the DMS, which is a relatively unexplored area in digital microfluidics. Based on the semi-empirical models of the droplet dynamic system, simulation results of the closed-loop position control of a droplet between two adjacent cells of a DMS are presented. The dynamic response is analyzed and discussed in relation to the operational parameters of a DMS.
- 1 December 2009
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 132 (1) , 014501
Simulation of Droplet Position Control in Digital Microfluidic Systems
Digital microfluidic systems (DMSs) are emerging with high potential to serve as true labs-on-a-chip (LOCs) systems for various chemical and biochemical analyses. Significant research efforts have been devoted toward the design and fabrication of improved LOC systems. Due to design, fabrication, and also runtime uncertainties, feedback control schemes must be incorporated to ensure reliability and accuracy of LOCs for practical use. This paper introduces the basics of the control analysis and design of the DMS, which is a relatively unexplored area in digital microfluidics. Based on the semi-empirical models of the droplet dynamic system, simulation results of the closed-loop position control of a droplet between two adjacent cells of a DMS are presented. The dynamic response is analyzed and discussed in relation to the operational parameters of a DMS.
- 13 October 2009
- Published by Springer Nature in Biomedical Microdevices
- Vol. 12 (1) , 115-124
Droplet position control in digital microfluidic systems
Research on so called digital microfluidic systems (DMS) capable of manipulating individual microdroplets on a cell-based structure has enormously increased in the past few years, mainly due to the demand of the technology-dependent biomedical applications. Significant research in this area has been related to the simulation and modeling of droplet motion, demonstration of different drop actuation techniques on laboratory-scale prototypes, and droplet routing and scheduling for more efficient assay procedures. This paper introduces the basics of the control analysis and design of a DMS, which is a relatively unexplored area in digital microfluidics. This paper starts with a discussion on a simplified dynamic model of droplet motion in a planar array of cells, and continues with more complicated dynamic models that are necessary to realize the structure of an appropriate closed-loop control system for the DMS. The control analysis and design includes both the transient and steady-state responses of the DMS under external driving forces. The proposed control analysis and design approach is implemented into SIMULINK® models to demonstrate the performance of the DMS through simulation using the system parameters previously reported in the literature.
- 13 October 2009
- Published by Springer Nature in Biomedical Microdevices
- Vol. 12 (1) , 115-124
Droplet position control in digital microfluidic systems
Research on so called digital microfluidic systems (DMS) capable of manipulating individual microdroplets on a cell-based structure has enormously increased in the past few years, mainly due to the demand of the technology-dependent biomedical applications. Significant research in this area has been related to the simulation and modeling of droplet motion, demonstration of different drop actuation techniques on laboratory-scale prototypes, and droplet routing and scheduling for more efficient assay procedures. This paper introduces the basics of the control analysis and design of a DMS, which is a relatively unexplored area in digital microfluidics. This paper starts with a discussion on a simplified dynamic model of droplet motion in a planar array of cells, and continues with more complicated dynamic models that are necessary to realize the structure of an appropriate closed-loop control system for the DMS. The control analysis and design includes both the transient and steady-state responses of the DMS under external driving forces. The proposed control analysis and design approach is implemented into SIMULINK® models to demonstrate the performance of the DMS through simulation using the system parameters previously reported in the literature.