Marko Matkovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marko Matkovic has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Alberto Cavallini
University of Padova, Padova, Italy
3 shared publicationsStefano Bortolin
University of Padova, Padova, Italy
3 shared publicationsDavide Del Col
University of Padova, Padova, Italy
2 shared publications- Davide Del Col
Department of Industrial Engineering, University of Padova, via Venezia 1, 35131 Padova, Italy
2 shared publications - Luisa Rossetto
Department of Industrial Engineering, University of Padova, 35131 Padova, Italy
2 shared publications - Alberto Cavallini
Industrial Engineering Department, Università degli Studi di Padova, 35122 Padova, Italy
1 shared publication
Latest Publications
- 1 January 2010
- Published by ASME International
- p. 187-196
Effect of Minichannel Cross Sectional Shape in Condensation
The objective of this work is to present new condensation heat transfer coefficients measured inside a single square cross section minichannel, having a 1.18 m side length, and compare them to the ones measured in a circular minichannel. This subject is particularly interesting since most of the mini and microchannels used in practical applications have non circular cross sections. The test section used in the present work is obtained from a thick wall copper tube which is machined to draw a complex passage for the coolant. This experimental technique allows to measure directly the temperature in the tube wall and in the water channel. The heat flux is determined from the temperature profile of the coolant in the measuring sector. The experimental technique is checked in single phase runs which represent a severe testing condition due to the low values of heat flux. Tests have been performed with R134a at 40°C saturation temperature, at mass velocities ranging between 200 and 800 kg m−2s−1. As compared to the heat transfer coefficients measured in a circular minichannel, in the square minichannel the authors find that heat transfer is enhanced at the lowest values of mass velocity; this must be due to the effect of the surface tension. No heat transfer coefficient increase has been found at the highest values of the mass velocity where condensation seems to be shear stress dominated.
- 1 January 2010
- Published by ASME International
- p. 187-196
Effect of Minichannel Cross Sectional Shape in Condensation
The objective of this work is to present new condensation heat transfer coefficients measured inside a single square cross section minichannel, having a 1.18 m side length, and compare them to the ones measured in a circular minichannel. This subject is particularly interesting since most of the mini and microchannels used in practical applications have non circular cross sections. The test section used in the present work is obtained from a thick wall copper tube which is machined to draw a complex passage for the coolant. This experimental technique allows to measure directly the temperature in the tube wall and in the water channel. The heat flux is determined from the temperature profile of the coolant in the measuring sector. The experimental technique is checked in single phase runs which represent a severe testing condition due to the low values of heat flux. Tests have been performed with R134a at 40°C saturation temperature, at mass velocities ranging between 200 and 800 kg m−2s−1. As compared to the heat transfer coefficients measured in a circular minichannel, in the square minichannel the authors find that heat transfer is enhanced at the lowest values of mass velocity; this must be due to the effect of the surface tension. No heat transfer coefficient increase has been found at the highest values of the mass velocity where condensation seems to be shear stress dominated.
- 21 January 2009
- Published by Wiley in Journal of Heat Transfer
- Vol. 131 (3) , 033107
Pressure Drop During Two-Phase Flow of R134a and R32 in a Single Minichannel
Condensation in minichannels is widely used in air-cooled condensers for the automotive and air-conditioning industry, heat pipes, and compact heat exchangers. The knowledge of pressure drops in such small channels is important in order to optimize heat transfer surfaces. Most of the available experimental work refers to measurements obtained within multiport smooth extruded tubes and deal with the average values over the number of parallel channels. In this context, the present authors have set up a new test apparatus for heat transfer and fluid flow studies in single minichannels. This paper presents new experimental frictional pressure gradient data, relative to single-phase flow and adiabatic two-phase flow of R134a and R32 inside a single horizontal minitube, with a 0.96 mm inner diameter and with not-negligible surface roughness. The new all-liquid and all-vapor data are successfully compared against predictions of single-phase flow models. Also the two-phase flow data are compared against a model previously developed by the present authors for adiabatic flow or flow during condensation of halogenated refrigerants inside smooth minichannels. Surface roughness effects on the liquid-vapor flow are discussed. In this respect, the friction factor in the proposed model is modified, in order to take into consideration also effects due to wall roughness.
- 21 January 2009
- Published by Wiley in Journal of Heat Transfer
- Vol. 131 (3) , 033107
Pressure Drop During Two-Phase Flow of R134a and R32 in a Single Minichannel
Condensation in minichannels is widely used in air-cooled condensers for the automotive and air-conditioning industry, heat pipes, and compact heat exchangers. The knowledge of pressure drops in such small channels is important in order to optimize heat transfer surfaces. Most of the available experimental work refers to measurements obtained within multiport smooth extruded tubes and deal with the average values over the number of parallel channels. In this context, the present authors have set up a new test apparatus for heat transfer and fluid flow studies in single minichannels. This paper presents new experimental frictional pressure gradient data, relative to single-phase flow and adiabatic two-phase flow of R134a and R32 inside a single horizontal minitube, with a 0.96 mm inner diameter and with not-negligible surface roughness. The new all-liquid and all-vapor data are successfully compared against predictions of single-phase flow models. Also the two-phase flow data are compared against a model previously developed by the present authors for adiabatic flow or flow during condensation of halogenated refrigerants inside smooth minichannels. Surface roughness effects on the liquid-vapor flow are discussed. In this respect, the friction factor in the proposed model is modified, in order to take into consideration also effects due to wall roughness.
- 1 January 2009
- Published by ASME International
- p. 147-154
Experimental Study of Condensation Inside a Horizontal Single Square Minichannel
This work is aimed at presenting experimental heat transfer coefficients measured during condensation inside a single square cross section minichannel, having a 1.18 mm side length. The experimental heat transfer coefficients are compared to the ones previously obtained in a circular minitube. This subject is particularly interesting since most of the mini and microchannels used in practical applications have non circular cross sections. The test section used in the present work is obtained from a thick wall copper tube which is machined to draw a complex passage for the water; its geometry has been studied with the aim of increasing the external heat transfer area and thus decreasing the external heat transfer resistance. This experimental technique allows to measure directly the temperature in the tube wall and in the water channel. The heat flux is determined from the temperature profile of the coolant in the measuring sector. The wall temperature is measured by means of thermocouples embedded in the copper tube, while the saturation temperature is obtained from the saturation pressure measured at the inlet and outlet of the measuring sector. On the whole, more than seventy thermocouples have been placed in the 23 cm long measuring section. Tests have been performed with R134a at 40°C saturation temperature, at mass velocities ranging between 200 and 800 kg m−2s−1. As compared to the heat transfer coefficients measured in a circular minichannel, in the square minichannel the authors find a heat transfer enhancement at the lowest values of mass velocity; this must be due to the effect of the surface tension. No heat transfer coefficient increase has been found at the highest values of the mass velocity where condensation is shear stress dominated.
- 1 January 2009
- Published by ASME International
- p. 147-154
Experimental Study of Condensation Inside a Horizontal Single Square Minichannel
This work is aimed at presenting experimental heat transfer coefficients measured during condensation inside a single square cross section minichannel, having a 1.18 mm side length. The experimental heat transfer coefficients are compared to the ones previously obtained in a circular minitube. This subject is particularly interesting since most of the mini and microchannels used in practical applications have non circular cross sections. The test section used in the present work is obtained from a thick wall copper tube which is machined to draw a complex passage for the water; its geometry has been studied with the aim of increasing the external heat transfer area and thus decreasing the external heat transfer resistance. This experimental technique allows to measure directly the temperature in the tube wall and in the water channel. The heat flux is determined from the temperature profile of the coolant in the measuring sector. The wall temperature is measured by means of thermocouples embedded in the copper tube, while the saturation temperature is obtained from the saturation pressure measured at the inlet and outlet of the measuring sector. On the whole, more than seventy thermocouples have been placed in the 23 cm long measuring section. Tests have been performed with R134a at 40°C saturation temperature, at mass velocities ranging between 200 and 800 kg m−2s−1. As compared to the heat transfer coefficients measured in a circular minichannel, in the square minichannel the authors find a heat transfer enhancement at the lowest values of mass velocity; this must be due to the effect of the surface tension. No heat transfer coefficient increase has been found at the highest values of the mass velocity where condensation is shear stress dominated.
- 1 January 2007
- Published by ASME International
- p. 901-909
Flow Boiling Inside a Single Circular Minichannel: Measurement of Local Heat Transfer Coefficient
This paper describes a new experimental apparatus for the measurement of the local heat transfer coefficient during flow boiling inside a 0.96 mm internal diameter single round cross section minichannel and reports preliminary heat transfer data taken during flow boiling of R134a. As a peculiar characteristic of the present technique, the heat transfer coefficient is not measured by imposing the heat flux; instead, the boiling process is governed by controlling the inlet temperature of the heating secondary fluid. This paper also presents a methodology to determine the critical conditions during the flow boiling process when no heat flux is imposed.
- 1 January 2007
- Published by ASME International
- p. 901-909
Flow Boiling Inside a Single Circular Minichannel: Measurement of Local Heat Transfer Coefficient
This paper describes a new experimental apparatus for the measurement of the local heat transfer coefficient during flow boiling inside a 0.96 mm internal diameter single round cross section minichannel and reports preliminary heat transfer data taken during flow boiling of R134a. As a peculiar characteristic of the present technique, the heat transfer coefficient is not measured by imposing the heat flux; instead, the boiling process is governed by controlling the inlet temperature of the heating secondary fluid. This paper also presents a methodology to determine the critical conditions during the flow boiling process when no heat flux is imposed.