Andrzej S. Baranski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrzej S. Baranski has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Piotr M. Diakowski
Department of Chemistry, University of Saskatchewan, 110 Science Place, Saskatoon, SK, Canada, S7N 5C9
2 shared publications
Latest Publications
- 9 March 2006
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 110 (13) , 6776-6784
High Frequency Faradaic Rectification Voltammetry at Microelectrodes
An experimental setup for carrying out faradaic rectification measurements at micrometer-sized electrodes under potential control is described. A new method of data analysis is proposed that allows the determination of the standard rate constant and the electron-transfer coefficient of a fast charge transfer process without knowing the impedance of the microelectrode. This method is based on the frequency dependence of the shape of the faradaic rectification voltammograms (i.e., the average width of the peaks and the ratio of the peak heights) rather than on the magnitude of the faradaic rectification signal. The method was tested in the determination of heterogeneous electron transfer kinetics of Fe(CN)63-/4- and Ru(NH3)62+/3+ in aqueous solutions on a platinum microelectrode (12.5 μm in radius) and ferrocene/ferrocinum redox couple in a dimethylformamide solution on a gold microelectrode (12.5 μm in radius).
- 9 March 2006
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 110 (13) , 6776-6784
High Frequency Faradaic Rectification Voltammetry at Microelectrodes
An experimental setup for carrying out faradaic rectification measurements at micrometer-sized electrodes under potential control is described. A new method of data analysis is proposed that allows the determination of the standard rate constant and the electron-transfer coefficient of a fast charge transfer process without knowing the impedance of the microelectrode. This method is based on the frequency dependence of the shape of the faradaic rectification voltammograms (i.e., the average width of the peaks and the ratio of the peak heights) rather than on the magnitude of the faradaic rectification signal. The method was tested in the determination of heterogeneous electron transfer kinetics of Fe(CN)63-/4- and Ru(NH3)62+/3+ in aqueous solutions on a platinum microelectrode (12.5 μm in radius) and ferrocene/ferrocinum redox couple in a dimethylformamide solution on a gold microelectrode (12.5 μm in radius).
- 3 July 2004
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 8 (10) , 683-692
Application of AC impedance techniques to Scanning Electrochemical Microscopy
- 3 July 2004
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 8 (10) , 683-692
Application of AC impedance techniques to Scanning Electrochemical Microscopy
- 7 February 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (6) , 1294-1301
Hot Microelectrodes
Heat generation at disk microelectrodes by a high-amplitude (few volt) and high-frequency (0.1−2 GHz) alternating voltage is described. This method allows changing electrode temperature very rapidly and maintaining it well above the boiling point of solution for a very long time without any indication of boiling. The size of the hot zone in solution is determined by the radius of the electrode. There is no obvious limit in regard to the electrode size, so theoretically, by this method, it should be possible to create hot spots that are much smaller than those created with laser beams. That could lead to potential applications in medicine and biology. The heat-generating waveform does not electrically interfere with normal electroanalytical measurements. The noise level at hot microelectrodes is only slightly higher, as compared to normal microelectodes, but diffusion-controlled currents at hot microelectrodes may be up to 7 times higher, and an enhancement of kinetically controlled currents may be even larger. Hot microelectrodes can be used for end-column detection in capillary electrophoresis and for in-line or in vivo analyses. Temperature gradients at hot microelectrodes may exceed 1.5 × 105 K/cm, which makes them useful in studies of Soret diffusion and thermoelectric phenomena.
- 7 February 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (6) , 1294-1301
Hot Microelectrodes
Heat generation at disk microelectrodes by a high-amplitude (few volt) and high-frequency (0.1−2 GHz) alternating voltage is described. This method allows changing electrode temperature very rapidly and maintaining it well above the boiling point of solution for a very long time without any indication of boiling. The size of the hot zone in solution is determined by the radius of the electrode. There is no obvious limit in regard to the electrode size, so theoretically, by this method, it should be possible to create hot spots that are much smaller than those created with laser beams. That could lead to potential applications in medicine and biology. The heat-generating waveform does not electrically interfere with normal electroanalytical measurements. The noise level at hot microelectrodes is only slightly higher, as compared to normal microelectodes, but diffusion-controlled currents at hot microelectrodes may be up to 7 times higher, and an enhancement of kinetically controlled currents may be even larger. Hot microelectrodes can be used for end-column detection in capillary electrophoresis and for in-line or in vivo analyses. Temperature gradients at hot microelectrodes may exceed 1.5 × 105 K/cm, which makes them useful in studies of Soret diffusion and thermoelectric phenomena.