TPTimothy W. Petersen

Timothy W. Petersen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Timothy W. Petersen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Ger van Den Engh

    The Institute for Systems Biology, Seattle, Washington

    3 shared publications
  • Alan H. Diercks

    Institute for Systems Biology, Seattle, Washington

    1 shared publication
  • Charles L. Asbury

    Department of Biological Sciences, Stanford University, Stanford, California

    1 shared publication
  • Jeanne L. Uy

    Cell Sorting Facility, Department of Pathology, University of Washington, Seattle, Washington, USA

    1 shared publication
  • Sherrif F. Ibrahim

    Institute for Systems Biology, Seattle, Washington

    1 shared publication

Latest Publications

  • Open Access

    Chromatic shifts in the fluorescence emitted by murine thymocytes stained with Hoechst 33342

    by Timothy W. Petersen, Sherrif F. Ibrahim, Alan H. Diercks, Ger van Den Engh

    Background: Many methods in flow cytometry rely on staining DNA with a fluorescent dye to gauge DNA content. From the relative intensity of the fluorescence signature, one can then infer position in cell cycle, amount of DNA (i.e., for sperm selection), or, as in the case of flow karyotyping, to distinguish individual chromosomes. This work examines the staining of murine thymocytes with a common DNA dye, Hoechst 33342, to investigate nonlinearities in the florescence intensity as well as chromatic shifts.Methods: Murine thymocytes were stained with Hoechst 33342 and measured in a flow cytometer at two fluorescence emission bands. In other measurements, cells were stained at different dye concentrations, and then centrifuged. The supernatant was then used for a second round of staining to test the amount of dye uptake. Finally, to test for resonant energy transfer, we measured fluorescence anisotropy at two different wavelengths.Results: The fluorescence of cells stained with Hoechst 33342 is a nonlinear process that shows an overall decrease in intensity with increased dye uptake, and spectral shift to the red. Along with the spectral shift of the fluorescence to the longer wavelengths, we document decreases in the fluorescence anisotropy that may indicate resonant energy transfer.Conclusions: At low concentrations, Hoechst 33342 binds to the minor groove of DNA and shows an increase in fluorescence and a blue shift upon binding. At higher concentrations, at which the dye molecules can no longer bind without overlapping, the blue fluorescence decreases and the red fluorescence increases until there is approximately one dye molecule per DNA base pair. The ratio of the blue fluorescence to the red fluorescence is an accurate indicator of the cellular dye concentration.


  • Open Access

    The polarization of fluorescence of DNA stains depends on the incorporation density of the dye molecules

    by Jeanne L. Uy, Charles L. Asbury, Timothy W. Petersen, Ger van Den Engh

    Background: The fluorescence induced by polarized light sources, such as the lasers that are used in flow cytometry, is often polarized and anisotropic. In addition, most optical detector systems are sensitive to the direction of polarization. These two factors influence the accuracy of fluorescence intensity measurements. The intensity of two light sources can be compared only if all details of the direction and degree of polarization are known. In a previous study, we observed that fluorescence polarization might be modified by dye–dye interactions. This report further investigates the role of dye density in fluorescence polarization anisotropy.Methods: We measured the polarization distribution of samples stained with commonly used DNA dyes. To determine the role of fluorophore proximity, we compared the monomeric and a dimeric form of the DNA dyes ethidium bromide (EB), thiazole orange (TO), and oxazole yellow (YO).Results: In all dyes sampled, fluorescence polarization is less at high dye concentrations than at low concentrations. The monomeric dyes exhibit a higher degree of polarization than the dimeric dyes of the same species.Conclusions: The polarization of fluorescence from DNA dyes is related to the density of incorporation into the DNA helix. Energy transfer between molecules that are in close proximity loosens the linkage between the excitation and emission dipoles, thereby reducing the degree of polarization of the emission.


  • Open Access

    Stability of the breakoff point in a high‐speed cell sorter

    by Timothy W. Petersen, Ger van Den Engh

    Background High-speed jet-in-air cytometric sorting requires knowledge of the time it takes a particle to travel from the laser to the point where the jet breaks into droplets. Variations in this breakoff time will result in poorer yields and poorer sort purities. Methods This work examined the physical mechanisms that lead to the break up of the jet into droplets and calculated the stability of the droplet breakoff time relative to physical parameters, which govern the behavior of the jet. Results We derived the variations in the breakoff time and found that small variations in the drive frequency, temperature, pressure, and drive amplitude can lead to correspondingly large changes in the breakoff time. We found explicitly that the time it takes the jet to break up is not necessarily correlated with the distance to the breakoff point. Conclusions Many high-speed cell sorters use active means to control the breakoff time. A common method to monitor the breakoff time is to visually monitor the breakoff point. This technique in fact may decrease the sorting purity and efficiency by inadvertently correcting for breakoff time variations. We show explicitly the breakoff time's dependence on a number of physical parameters that can be monitored to increase the stability of the breakoff time. Cytometry Part A 56A:63–70, 2003.