Jeffrey J. Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jeffrey J. Kim has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Bryan C. Cannon
Section of Pediatric Cardiology, Department of Pediatrics, Baylor College of Medicine, Texas Children's Hospital, Houston, Texas, USA
5 shared publicationsNaomi J. Kertesz
Section of Pediatric Cardiology, Department of Pediatrics, Baylor College of Medicine, Texas Children's Hospital, Houston, Texas, USA
5 shared publicationsSusan W. Denfield
Department of Pediatrics,Texas Children's Hospital/Baylor College of Medicine,Houston,Texas,United States of America
4 shared publicationsWilliam J. Dreyer
Department of Pediatrics,Texas Children's Hospital/Baylor College of Medicine,Houston,Texas,United States of America
4 shared publicationsJack F. Price
Department of Pediatrics,Texas Children's Hospital/Baylor College of Medicine,Houston,Texas,United States of America
3 shared publicationsJeffrey A. Towbin
3 shared publications
Latest Publications
- 1 February 2020
- Published by Elsevier in Heart Rhythm
- Vol. 17 (2) , 294-295
Cost utility of wearable cardioverter-defibrillators in children with dilated cardiomyopathy during medical optimization: Is it worth the wait?
- 1 February 2020
- Published by Elsevier in Heart Rhythm
- Vol. 17 (2) , 294-295
Cost utility of wearable cardioverter-defibrillators in children with dilated cardiomyopathy during medical optimization: Is it worth the wait?
- 26 November 2013
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 25 (2) , 255-260
Arrhythmias in children with ventricular assist devices
Background: Children with decompensated heart failure are at high risk for arrhythmias, and ventricular assist device placement is becoming a more common treatment strategy. The impact of ventricular assist devices on arrhythmias and how arrhythmias affect the clinical course of this population are not well described. Methods and results: A single-centre retrospective analysis of children receiving a ventricular assist device between 1998 and 2011 was performed. In all, 45 patients received 56 ventricular assist devices. The median age at initial placement was 13 years (interquartile range 6–15). The median duration of support was 10 days (range 2–260). The aetiology of heart failure included cardiomyopathy, transplant rejection, myocarditis, and congenital heart disease. In all, 32 patients (71%) had an arrhythmia; 19 patients (42%) had an arrhythmia before ventricular assist device and eight patients (18%) developed new arrhythmias on ventricular assist device. Ventricular tachycardia was most common (25/32, 78%). There was no correlation between arrhythmia and risk of death or transplantation (p=0.14). Of the 15 patients who weaned from ventricular assist device, post-ventricular assist device arrhythmias occurred in nine (60%), with five (33%) having their first arrhythmia after weaning. Patients with ventricular dysfunction after ventricular assist device were more likely to have arrhythmias (pConclusions: Arrhythmias, especially ventricular, are common in children requiring ventricular assist device. They frequently persist for those able to wean from ventricular assist device.
- 26 November 2013
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 25 (2) , 255-260
Arrhythmias in children with ventricular assist devices
Background: Children with decompensated heart failure are at high risk for arrhythmias, and ventricular assist device placement is becoming a more common treatment strategy. The impact of ventricular assist devices on arrhythmias and how arrhythmias affect the clinical course of this population are not well described. Methods and results: A single-centre retrospective analysis of children receiving a ventricular assist device between 1998 and 2011 was performed. In all, 45 patients received 56 ventricular assist devices. The median age at initial placement was 13 years (interquartile range 6–15). The median duration of support was 10 days (range 2–260). The aetiology of heart failure included cardiomyopathy, transplant rejection, myocarditis, and congenital heart disease. In all, 32 patients (71%) had an arrhythmia; 19 patients (42%) had an arrhythmia before ventricular assist device and eight patients (18%) developed new arrhythmias on ventricular assist device. Ventricular tachycardia was most common (25/32, 78%). There was no correlation between arrhythmia and risk of death or transplantation (p=0.14). Of the 15 patients who weaned from ventricular assist device, post-ventricular assist device arrhythmias occurred in nine (60%), with five (33%) having their first arrhythmia after weaning. Patients with ventricular dysfunction after ventricular assist device were more likely to have arrhythmias (pConclusions: Arrhythmias, especially ventricular, are common in children requiring ventricular assist device. They frequently persist for those able to wean from ventricular assist device.
- 26 August 2009
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 20 (9) , 1065-1067
Cross‐Stimulation: A Rare Complication of Chronic Epicardial Leads
Cross-stimulation is a rare phenomenon that occurs during dual-chamber pacing when the pacing stimulus to one chamber results in the inadvertent capture of the other. Most cases are attributable to intrinsic design features of particular device models or lead malpositioning, and only occur early postimplantation with subsequent spontaneous resolution. We report a case of cross-stimulation occurring in a patient with chronic epicardial leads without loss of lead integrity.
- 26 August 2009
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 20 (9) , 1065-1067
Cross‐Stimulation: A Rare Complication of Chronic Epicardial Leads
Cross-stimulation is a rare phenomenon that occurs during dual-chamber pacing when the pacing stimulus to one chamber results in the inadvertent capture of the other. Most cases are attributable to intrinsic design features of particular device models or lead malpositioning, and only occur early postimplantation with subsequent spontaneous resolution. We report a case of cross-stimulation occurring in a patient with chronic epicardial leads without loss of lead integrity.
- 8 November 2007
- Published by Springer Nature in Pediatric Cardiology
- Vol. 29 (5) , 986-988
Isolated Junctional Tachycardia in a Patient with Pheochromocytoma: An Unusual Presentation of an Uncommon Disease
Pheochromocytoma is a rare disease, which often presents a diagnostic challenge due to a variable symptom presentation complex. We report the case of a child who presented with isolated symptoms of palpitations and was found to have junctional tachycardia with subsequent development of cardiomyopathy. Further evaluation revealed that she had an extra-adrenal pheochromocytoma, which was the cause of her arrhythmia and subsequent symptomatology.
- 8 November 2007
- Published by Springer Nature in Pediatric Cardiology
- Vol. 29 (5) , 986-988
Isolated Junctional Tachycardia in a Patient with Pheochromocytoma: An Unusual Presentation of an Uncommon Disease
Pheochromocytoma is a rare disease, which often presents a diagnostic challenge due to a variable symptom presentation complex. We report the case of a child who presented with isolated symptoms of palpitations and was found to have junctional tachycardia with subsequent development of cardiomyopathy. Further evaluation revealed that she had an extra-adrenal pheochromocytoma, which was the cause of her arrhythmia and subsequent symptomatology.
- 1 November 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (11) , 1404-1407
Maintenance of AV Synchrony in a Small Child Utilizing Two Pacemakers and the Triggered VVT Mode:. Triggered Pacing in Small Children
Infants and small children with atrioventricular (AV) nodal disease frequently require pacing in order to maintain an adequate heart rate. The maintenance of AV synchrony is physiologically optimal in this setting. Unfortunately, small size and congenital anomalies often preclude the placement of standard transvenous dual chamber pacing systems. We report the case of a small child with a pre-existing dual chamber epicardial pacing system and subsequent ventricular lead dysfunction who underwent implantation of a new single chamber transvenous system which was programmed in VVT (triggered) mode in order to maintain AV synchrony.
- 1 November 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (11) , 1404-1407
Maintenance of AV Synchrony in a Small Child Utilizing Two Pacemakers and the Triggered VVT Mode:. Triggered Pacing in Small Children
Infants and small children with atrioventricular (AV) nodal disease frequently require pacing in order to maintain an adequate heart rate. The maintenance of AV synchrony is physiologically optimal in this setting. Unfortunately, small size and congenital anomalies often preclude the placement of standard transvenous dual chamber pacing systems. We report the case of a small child with a pre-existing dual chamber epicardial pacing system and subsequent ventricular lead dysfunction who underwent implantation of a new single chamber transvenous system which was programmed in VVT (triggered) mode in order to maintain AV synchrony.
- 21 February 2007
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (4) , 373-377
Ventricular Function and Long‐Term Pacing in Children with Congenital Complete Atrioventricular Block
Objective: To determine the sequela of right ventricular pacing in children with congenital complete atrioventricular block. Background: Pacing is a well‐accepted therapy for patients with congenital complete atrioventricular block. The long‐term sequela of right ventricular pacing in this population has not been well described. Methods: We performed a cohort study on all patients with congenital complete atrioventricular block who underwent pacemaker implantation at our institution from 1972 to 2004. Patients with associated congenital heart disease or ventricular dysfunction prior to pacemaker implantation were excluded. Results: A total of 63 patients were included in the study. The median age at pacemaker implantation was 6.5 years, with an average follow‐up of 9.9 years. The cumulative dysfunction free survival at 20 years was 92%. In total, four patients (6%) were noted to develop LV dysfunction an average of 15.1 years after pacemaker implantation. Of 30 patients who were paced for >10 years, only three (10%) developed echocardiographic evidence of LV dysfunction. Right ventricular apex pacing and prolonged QRS duration were found to be predictive of decreased long‐term LV systolic function (P < 0.05). Conclusions: Left ventricular dysfunction in patients with congenital complete atrioventricular block is a rare finding, even in those who have been paced for more than 10 years. Right ventricular apex pacing and prolonged QRS duration may be associated with decreased ventricular function over time. At this time, with such a low incidence of cardiac dysfunction, right ventricular pacing should be considered an acceptable first‐line therapy in this population.
- 21 February 2007
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (4) , 373-377
Ventricular Function and Long‐Term Pacing in Children with Congenital Complete Atrioventricular Block
Objective: To determine the sequela of right ventricular pacing in children with congenital complete atrioventricular block. Background: Pacing is a well‐accepted therapy for patients with congenital complete atrioventricular block. The long‐term sequela of right ventricular pacing in this population has not been well described. Methods: We performed a cohort study on all patients with congenital complete atrioventricular block who underwent pacemaker implantation at our institution from 1972 to 2004. Patients with associated congenital heart disease or ventricular dysfunction prior to pacemaker implantation were excluded. Results: A total of 63 patients were included in the study. The median age at pacemaker implantation was 6.5 years, with an average follow‐up of 9.9 years. The cumulative dysfunction free survival at 20 years was 92%. In total, four patients (6%) were noted to develop LV dysfunction an average of 15.1 years after pacemaker implantation. Of 30 patients who were paced for >10 years, only three (10%) developed echocardiographic evidence of LV dysfunction. Right ventricular apex pacing and prolonged QRS duration were found to be predictive of decreased long‐term LV systolic function (P < 0.05). Conclusions: Left ventricular dysfunction in patients with congenital complete atrioventricular block is a rare finding, even in those who have been paced for more than 10 years. Right ventricular apex pacing and prolonged QRS duration may be associated with decreased ventricular function over time. At this time, with such a low incidence of cardiac dysfunction, right ventricular pacing should be considered an acceptable first‐line therapy in this population.
- 1 December 2006
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 25 (12) , 1480-1482
Mechanical Circulatory Support as a Bridge to Combined Dual Organ Transplantation in Children
- 1 December 2006
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 25 (12) , 1480-1482
Mechanical Circulatory Support as a Bridge to Combined Dual Organ Transplantation in Children
- 1 February 2006
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 25 (2) , 195-199
Leukocyte Suppression is Associated with Improved Clinical Outcomes in Children’s Status after Orthotopic Heart Transplantation
- 1 February 2006
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 25 (2) , 195-199
Leukocyte Suppression is Associated with Improved Clinical Outcomes in Children’s Status after Orthotopic Heart Transplantation
- 1 September 2005
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 24 (9) , 1444.e13-1444.e14
Radio-Frequency Catheter Ablation of Accessory Pathway Mediated Tachycardia in a Child After Orthotopic Heart Transplantation
- 1 September 2005
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 24 (9) , 1444.e13-1444.e14
Radio-Frequency Catheter Ablation of Accessory Pathway Mediated Tachycardia in a Child After Orthotopic Heart Transplantation