Manuela Haunschmidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manuela Haunschmidt has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Christian W. Klampfl
Institute of Analytical and General Chemistry, Faculty of Engineering and Natural Sciences, Johannes Kepler University Linz, 4040 Linz, Austria
4 shared publications - Wolfgang Buchberger
Institute of Analytical and General Chemistry, Faculty of Engineering and Natural Sciences, Johannes Kepler University Linz, 4040 Linz, Austria
4 shared publications Robert Hertsens
JEOL (Europe) BV, Leuvensesteenweg 542, Zaventem, Belgium
3 shared publications
Latest Publications
- 7 December 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (1) , 99-104
Identification and semi-quantitative analysis of parabens and UV filters in cosmetic products by direct-analysis-in-real-time mass spectrometry and gas chromatography with mass spectrometric detection
A method based on direct-analysis-in-real-time mass spectrometry (DART-MS) for the qualitative and semi-quantitative analysis of eight organic UV filters and four parabens in twelve cosmetic products with substantially different formulations (as cream, milk, lotion, oil, lipstick) was developed. All tested substances could be identified unambiguously in the investigated samples without any sample pre-treatment. Direct analysis of cosmetic products allows semi-quantitative determination of parabens. For UV filters no satisfactory results were obtained by direct analysis but all analytes could be quantified by simply dissolving the samples in methanol, addition of an internal standard and subsequent measurement of the solution by DART-MS without further pre-treatment. The results obtained using DART-MS were confirmed by a more established method namely gas chromatography with mass spectrometric detection (GC-MS).
- 7 December 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (1) , 99-104
Identification and semi-quantitative analysis of parabens and UV filters in cosmetic products by direct-analysis-in-real-time mass spectrometry and gas chromatography with mass spectrometric detection
A method based on direct-analysis-in-real-time mass spectrometry (DART-MS) for the qualitative and semi-quantitative analysis of eight organic UV filters and four parabens in twelve cosmetic products with substantially different formulations (as cream, milk, lotion, oil, lipstick) was developed. All tested substances could be identified unambiguously in the investigated samples without any sample pre-treatment. Direct analysis of cosmetic products allows semi-quantitative determination of parabens. For UV filters no satisfactory results were obtained by direct analysis but all analytes could be quantified by simply dissolving the samples in methanol, addition of an internal standard and subsequent measurement of the solution by DART-MS without further pre-treatment. The results obtained using DART-MS were confirmed by a more established method namely gas chromatography with mass spectrometric detection (GC-MS).
- 3 February 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (1) , 269-275
Determination of organic UV filters in water by stir bar sorptive extraction and direct analysis in real-time mass spectrometry
A screening method for analyzing environmental waters contaminated with UV filters using direct analysis in real-time mass spectrometry (DART-MS) was developed. To demonstrate the suitability of DART-MS a test set of seven organic UV filters, namely benzophenone-3 (BP-3), ethylhexyl dimethyl p-aminobenzoate (OD-PABA), 4-t-butyl-4′-methoxydibenzoylmethane (BM-DBM), homomethyl salicylate (HMS), 2-(ethylhexyl) salicylate (EHS), octocrylene (OC), and 4-methylbenzylidene camphor (4-MBC), was defined. In the first step, standard solutions of the analytes prepared in methanol were investigated in order to determine optimum parameters for the DART-MS. Because of the very low concentrations of UV filters expected in environmental water samples, a pre-concentration step using stir bar sorptive extraction was performed. DART-MS allows the direct, simple and rapid semi-quantitative analysis of the analytes enriched on the surface of the polydimethylsiloxane-coated stir bars. The optimized method provided calibration curves with correlation coefficients R > 0.959, repeatability from 5% (for 4-MBC) to 30% (for BM-DBM) relative standard deviation and limits of detection lower than 40 ng L−1 for all analytes. Finally, real lake water samples from locations with typical leisure activities were analyzed. Results obtained with the developed DART-MS method were cross-checked by confirmatory analysis using thermodesorption gas chromatography mass spectrometry (TD-GC-MS). Thereby, it could be demonstrated that both analytical methods provide comparable concentrations for the UV filters in the lake water samples.
- 3 February 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (1) , 269-275
Determination of organic UV filters in water by stir bar sorptive extraction and direct analysis in real-time mass spectrometry
A screening method for analyzing environmental waters contaminated with UV filters using direct analysis in real-time mass spectrometry (DART-MS) was developed. To demonstrate the suitability of DART-MS a test set of seven organic UV filters, namely benzophenone-3 (BP-3), ethylhexyl dimethyl p-aminobenzoate (OD-PABA), 4-t-butyl-4′-methoxydibenzoylmethane (BM-DBM), homomethyl salicylate (HMS), 2-(ethylhexyl) salicylate (EHS), octocrylene (OC), and 4-methylbenzylidene camphor (4-MBC), was defined. In the first step, standard solutions of the analytes prepared in methanol were investigated in order to determine optimum parameters for the DART-MS. Because of the very low concentrations of UV filters expected in environmental water samples, a pre-concentration step using stir bar sorptive extraction was performed. DART-MS allows the direct, simple and rapid semi-quantitative analysis of the analytes enriched on the surface of the polydimethylsiloxane-coated stir bars. The optimized method provided calibration curves with correlation coefficients R > 0.959, repeatability from 5% (for 4-MBC) to 30% (for BM-DBM) relative standard deviation and limits of detection lower than 40 ng L−1 for all analytes. Finally, real lake water samples from locations with typical leisure activities were analyzed. Results obtained with the developed DART-MS method were cross-checked by confirmatory analysis using thermodesorption gas chromatography mass spectrometry (TD-GC-MS). Thereby, it could be demonstrated that both analytical methods provide comparable concentrations for the UV filters in the lake water samples.
- 27 November 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (1) , 80-85
Rapid identification of stabilisers in polypropylene using time-of-flight mass spectrometry and DART as ion source
A method for analysing plastic samples without any sample pretreatment using direct analysis in real time mass spectrometry (DART-MS) was developed. DART-MS allows the direct, simple and rapid identification of polymer additives in plastic products. To demonstrate the suitability of DART-MS for the detection of a wide range of commonly employed stabilising agents, a test set of 21 stabilisers was selected. In a first step standard solutions of these stabilisers in toluene as well as toluene-extracts from polymer samples were analysed. Subsequently, to prove the applicability of the developed DART-MS method also for the direct analysis of plastic products, samples of polypropylene containing a range of stabilisers were prepared using a lab-scale compounder. Polymer samples were cut into 0.5 cm wide pieces and directly placed into the DART ion source. Focusing on the DART ionisation, several parameters like discharge needle potential, potential of the grid electrode and the discharge electrode, the heater temperature and the gas flow had to be varied to guarantee optimum results. Both positive and negative ionisation was tested, whereby the positive ion mode led to higher signal intensities for all analytes. Determination of accurate masses to improve the certainty in signal assignment could be achieved by using PEG 600 as an internal standard for mass calibration. The developed method allowed the detection of all selected additives (including some of their degradation products) in real polymer samples.
- 27 November 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (1) , 80-85
Rapid identification of stabilisers in polypropylene using time-of-flight mass spectrometry and DART as ion source
A method for analysing plastic samples without any sample pretreatment using direct analysis in real time mass spectrometry (DART-MS) was developed. DART-MS allows the direct, simple and rapid identification of polymer additives in plastic products. To demonstrate the suitability of DART-MS for the detection of a wide range of commonly employed stabilising agents, a test set of 21 stabilisers was selected. In a first step standard solutions of these stabilisers in toluene as well as toluene-extracts from polymer samples were analysed. Subsequently, to prove the applicability of the developed DART-MS method also for the direct analysis of plastic products, samples of polypropylene containing a range of stabilisers were prepared using a lab-scale compounder. Polymer samples were cut into 0.5 cm wide pieces and directly placed into the DART ion source. Focusing on the DART ionisation, several parameters like discharge needle potential, potential of the grid electrode and the discharge electrode, the heater temperature and the gas flow had to be varied to guarantee optimum results. Both positive and negative ionisation was tested, whereby the positive ion mode led to higher signal intensities for all analytes. Determination of accurate masses to improve the certainty in signal assignment could be achieved by using PEG 600 as an internal standard for mass calibration. The developed method allowed the detection of all selected additives (including some of their degradation products) in real polymer samples.
- 24 September 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1213 (1) , 88-92
Investigations on the migration behaviour of purines and pyrimidines in capillary electromigration techniques with UV detection and mass spectrometric detection
- 24 September 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1213 (1) , 88-92
Investigations on the migration behaviour of purines and pyrimidines in capillary electromigration techniques with UV detection and mass spectrometric detection