NENoah J. Epstein

Noah J. Epstein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Noah J. Epstein has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 July 2007
      • Vol. 36  (7) , E107-10

    Utility of judet oblique x-rays in preoperative assessment of acetabular periprosthetic osteolysis: a preliminary study.

    by Adrian Thomas, Noah J Epstein, Kathryn Stevens, Stuart B Goodman

    Anteroposterior (AP) x-rays provide limited information about size and location of acetabular osteolytic lesions after total hip arthroplasty (THA). In the study reported here, we sought to determine the utility of oblique (Judet) x-rays in preoperative assessment of acetabular lesions. AP, anterior (obturator), and posterior (iliac oblique) x-rays of 10 patients (10 hips) who underwent revision THA were evaluated retrospectively. Mean osteolytic area was 790 mm2 (SD, 520 mm2) on anterior oblique x-rays and 384 mm2 (SD, 396 mm2) on AP x-rays (P = .005). Mean osteolytic area on posterior oblique x-rays was 512 mm2 (SD, 430 mm2) (P = .34). Judet x-rays were useful in determining size and location of acetabular osteolysis.


  • Proinflammatory mediator expression in a novel murine model of titanium‐particle–induced intramedullary inflammation

    by Bryan A. Warme, Noah J. Epstein, Michael C. D. Trindade, Keita Miyanishi, Ting Ma, Ramin R. Saket, Donald Regula, Stuart B. Goodman, R. Lane Smith

    Wear debris from total joint replacement prostheses is implicated in periprosthetic osteolysis and implant loosening. The pathophysiology of this biological process remains unclear. Animal models of particle‐induced osteolysis have proven useful in the study of specific tissue responses to wear debris. However, existing in vivo murine models of particle‐mediated inflammation do not permit analysis of cortical bone degradation. This study describes a murine model of particle disease using an intramedullary rod in the mouse femur to parallel the clinical situation. The model consists of placing a 10‐mm‐long Kirschner wire retrograde in both femurs of C57b1/6 male mice via a medial parapatellar arthrotomy. Phagocytosable titanium particles were also implanted unilaterally to replicate generation of wear debris. Mice were sacrificed at 2, 10, and 26 weeks and whole femurs were cultured for 72 h. Levels of interleukin‐6, monocyte chemotactic protein‐1, and macrophage colony stimulating factor were assayed by ELISA. Transverse histological sections, at the level of the implant, were taken and stained with hematoxylin and eosin (H&E). Results demonstrated increased expression of proinflammatory mediators at 2 weeks in femora with rod and particles compared to femora with rods alone. Destruction of the endosteum was evident at 2, 10, and 26 weeks in the femora with titanium. This novel murine model of particle‐induced intramedullary inflammation may facilitate cost‐effective genetic studies and offers investigators a simple, clinically relevant intramedullary model to readily examine the pathogenesis of particle‐mediated periprosthetic osteolysis. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 71B: 360–366, 2004