Makoto Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Makoto Tanaka has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Toshiaki Nishikawa
21 shared publicationsTetsu Kimura
4 shared publicationsToru Goyagi
4 shared publicationsMasayoshi Sato
2 shared publicationsRie Nitta
2 shared publicationsAtsushi Saito
Resident
1 shared publication
Latest Publications
- 1 May 2005
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 100 (5) , 1325-1332
The Concentration-Dependent Effects of General Anesthesia on Spontaneous Baroreflex Indices and Their Correlations with Pharmacological Gains
Beat-to-beat assessment of spontaneously occurring fluctuations in heart rate and arterial blood pressure allows noninvasive determination of cardiovagal function, but little is known regarding the effects of general anesthesia on spontaneous baroreflex (SBR) indices. We examined (a) concentration-dependent effects of sevoflurane on SBR indices, heart rate variability (HRV), and blood pressure variability and (b) correlation and agreement between pharmacological baroreflex gains and SBR indices during sevoflurane anesthesia. Continuous electrocardiogram and invasive arterial blood pressure were monitored in nine healthy volunteers before, during, and for 3 h after sevoflurane anesthesia, during which end-tidal sevoflurane was maintained at 0.7%, 1.4%, and 2.0% in random sequences. We derived three SBR indices (sequence method, alpha-index, and low-frequency transfer function) and compared them with pressor and depressor test gains by the pharmacological method. HRV and blood pressure variability were analyzed at a fixed respiratory rate (12 breaths/min) in awake and anesthetized conditions. Except for low-frequency transfer function, SBR indices were depressed by sevoflurane and remained depressed for 30 min after emergence from anesthesia, compared with the conscious baseline value. Spontaneous sequence indices and high- and low-frequency powers of HRV demonstrated concentration-dependent depression. Pharmacological gains and SBR indices during anesthesia generally correlated well, but Bland-Altman analysis revealed that SBR indices had limits of agreement as large as the baroreflex gain itself. These data suggest that spontaneous indices are inadequate estimates of, and are inconsistent with, the pharmacological baroreflex gain during sevoflurane anesthesia.
- 1 May 2005
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 100 (5) , 1325-1332
The Concentration-Dependent Effects of General Anesthesia on Spontaneous Baroreflex Indices and Their Correlations with Pharmacological Gains
Beat-to-beat assessment of spontaneously occurring fluctuations in heart rate and arterial blood pressure allows noninvasive determination of cardiovagal function, but little is known regarding the effects of general anesthesia on spontaneous baroreflex (SBR) indices. We examined (a) concentration-dependent effects of sevoflurane on SBR indices, heart rate variability (HRV), and blood pressure variability and (b) correlation and agreement between pharmacological baroreflex gains and SBR indices during sevoflurane anesthesia. Continuous electrocardiogram and invasive arterial blood pressure were monitored in nine healthy volunteers before, during, and for 3 h after sevoflurane anesthesia, during which end-tidal sevoflurane was maintained at 0.7%, 1.4%, and 2.0% in random sequences. We derived three SBR indices (sequence method, alpha-index, and low-frequency transfer function) and compared them with pressor and depressor test gains by the pharmacological method. HRV and blood pressure variability were analyzed at a fixed respiratory rate (12 breaths/min) in awake and anesthetized conditions. Except for low-frequency transfer function, SBR indices were depressed by sevoflurane and remained depressed for 30 min after emergence from anesthesia, compared with the conscious baseline value. Spontaneous sequence indices and high- and low-frequency powers of HRV demonstrated concentration-dependent depression. Pharmacological gains and SBR indices during anesthesia generally correlated well, but Bland-Altman analysis revealed that SBR indices had limits of agreement as large as the baroreflex gain itself. These data suggest that spontaneous indices are inadequate estimates of, and are inconsistent with, the pharmacological baroreflex gain during sevoflurane anesthesia.
- 7 September 2004
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 48 (9) , 1163-1167
Effects of nitrous oxide on baroreflex gain and heart rate variability
Background: Spontaneous baroreflex method allows continuous assessment of cardiovagal reflex function within resting blood pressure, but effects of nitrous oxide, per se, on the spontaneous baroreflex response remain unknown. This study was designed to determine the effects of nitrous oxide on spontaneous baroreflex gain and heart rate variability assessed by power spectral analysis in humans.Methods: Electrocardiogram and non‐invasive blood pressure were monitored in 12 healthy volunteers before and during a 15‐min inhalation of 67% nitrous oxide in oxygen, while spontaneous respiration was maintained. Least‐square regression analysis relating R‐R interval and systolic blood pressure was performed to obtain spontaneous baroreflex gains. Heart rate variability was analyzed using fast Fourier transformation.Results: Nitrous oxide did not significantly alter spontaneous baroreflex gains, which correlated well with high‐frequency power (0.15–0.4 Hz) of heart rate variability before and during nitrous oxide inhalation.Conclusion: Our results indicate that (a) cardiovagal reflex response is not affected by nitrous oxide, per se, and (b) spontaneous baroreflex responses closely reflect beat‐to‐beat dynamic modulation of the cardiac cycle by the parasympathetic nervous system during inhalation of 67% nitrous oxide.
- 7 September 2004
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 48 (9) , 1163-1167
Effects of nitrous oxide on baroreflex gain and heart rate variability
Background: Spontaneous baroreflex method allows continuous assessment of cardiovagal reflex function within resting blood pressure, but effects of nitrous oxide, per se, on the spontaneous baroreflex response remain unknown. This study was designed to determine the effects of nitrous oxide on spontaneous baroreflex gain and heart rate variability assessed by power spectral analysis in humans.Methods: Electrocardiogram and non‐invasive blood pressure were monitored in 12 healthy volunteers before and during a 15‐min inhalation of 67% nitrous oxide in oxygen, while spontaneous respiration was maintained. Least‐square regression analysis relating R‐R interval and systolic blood pressure was performed to obtain spontaneous baroreflex gains. Heart rate variability was analyzed using fast Fourier transformation.Results: Nitrous oxide did not significantly alter spontaneous baroreflex gains, which correlated well with high‐frequency power (0.15–0.4 Hz) of heart rate variability before and during nitrous oxide inhalation.Conclusion: Our results indicate that (a) cardiovagal reflex response is not affected by nitrous oxide, per se, and (b) spontaneous baroreflex responses closely reflect beat‐to‐beat dynamic modulation of the cardiac cycle by the parasympathetic nervous system during inhalation of 67% nitrous oxide.
- 1 September 2004
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 99 (3) , 924-929
The Effects of Cervical and Lumbar Epidural Anesthesia on Heart Rate Variability and Spontaneous Sequence Baroreflex Sensitivity
A high level of neuroaxial block may produce profound bradycardia and hypotension, possibly as a result of an imbalance between sympathetic and parasympathetic control of heart rate. We designed this study to test the hypothesis that cervical epidural anesthesia would increase the high-frequency (HF) component of heart rate variability (HRV) as a result of cardiac sympathectomy, whereas lumbar epidural anesthesia would cause sympathetic predominance. HRV and spontaneous baroreflex (SBR) sensitivity were assessed before and after cervical and lumbar epidural anesthesia by using plain 1.5% lidocaine (median upper/lower sensory block: C3/T8 for cervical and T11/L5 for lumbar) in healthy patients (n = 10 each). Electrocardiogram and noninvasive beat-to-beat arterial blood pressure were monitored. HRV was analyzed by using fast Fourier transformation. Least-square regression analysis relating R-R interval and systolic blood pressure during spontaneous fluctuation was performed to obtain SBR sensitivities. Cervical epidural group patients were significantly older (P < 0.01) and taller (P < 0.01). Cervical epidural anesthesia attenuated HF (0.15–0.4 Hz) and low-frequency (0.04–0.15 Hz) power of HRV with concomitant reductions in up- and down-sequence SBR sensitivities, suggesting decreased vagal modulation of heart rate. Lumbar epidural anesthesia resulted in a significant increase in the low-frequency/HF ratio of HRV and unchanged SBR indices, suggesting sympathetic predominance. HF power correlated well with SBR sensitivities under most of our study conditions. Respiratory rates and PaCO2 were unchanged by either epidural technique. Our results indicate that cervical, but not lumbar, epidural anesthesia depresses phasic and tonic dynamic modulation of the cardiac cycle by the vagal nerve in conscious humans.
- 1 September 2004
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 99 (3) , 924-929
The Effects of Cervical and Lumbar Epidural Anesthesia on Heart Rate Variability and Spontaneous Sequence Baroreflex Sensitivity
A high level of neuroaxial block may produce profound bradycardia and hypotension, possibly as a result of an imbalance between sympathetic and parasympathetic control of heart rate. We designed this study to test the hypothesis that cervical epidural anesthesia would increase the high-frequency (HF) component of heart rate variability (HRV) as a result of cardiac sympathectomy, whereas lumbar epidural anesthesia would cause sympathetic predominance. HRV and spontaneous baroreflex (SBR) sensitivity were assessed before and after cervical and lumbar epidural anesthesia by using plain 1.5% lidocaine (median upper/lower sensory block: C3/T8 for cervical and T11/L5 for lumbar) in healthy patients (n = 10 each). Electrocardiogram and noninvasive beat-to-beat arterial blood pressure were monitored. HRV was analyzed by using fast Fourier transformation. Least-square regression analysis relating R-R interval and systolic blood pressure during spontaneous fluctuation was performed to obtain SBR sensitivities. Cervical epidural group patients were significantly older (P < 0.01) and taller (P < 0.01). Cervical epidural anesthesia attenuated HF (0.15–0.4 Hz) and low-frequency (0.04–0.15 Hz) power of HRV with concomitant reductions in up- and down-sequence SBR sensitivities, suggesting decreased vagal modulation of heart rate. Lumbar epidural anesthesia resulted in a significant increase in the low-frequency/HF ratio of HRV and unchanged SBR indices, suggesting sympathetic predominance. HF power correlated well with SBR sensitivities under most of our study conditions. Respiratory rates and PaCO2 were unchanged by either epidural technique. Our results indicate that cervical, but not lumbar, epidural anesthesia depresses phasic and tonic dynamic modulation of the cardiac cycle by the vagal nerve in conscious humans.
- 1 January 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (1) , 28-32
Hemodilution Does Not Alter Arterial Baroreflex Control of Heart Rate in Anesthetized Dogs
The cardiovascular effects of acute normovolemic hemodilution (ANH) are characterized by increased cardiac output and decreased systemic vascular resistance. However, whether arterial baroreflex function is altered by ANH remains undetermined. We assigned 23 anesthetized, mechanically ventilated dogs to mild ANH (hemoglobin, 7-8 g/dL; n = 11) or profound ANH (hemoglobin, 4-5 g/dL; n = 12) achieved by phlebotomy and simultaneous exchange with lactated Ringer's solution at 1:3 ratio to maintain constant central venous pressure and pulmonary artery occluded pressure. Baroreflex sensitivity was assessed by measurements of RR intervals of the electrocardiogram and mean arterial blood pressure (MAP) through a femoral artery catheter. Baroreflex responses were triggered by bolus IV injections of phenylephrine (25-75 micro g) and nitroprusside (50-100 micro g). The linear portion of the baroreflex curves relating RR intervals and MAP were used to determine baroreflex sensitivities. Compared with the predilution period, both ANH groups had significant increases in cardiac output and decreases in systemic vascular resistance (P < 0.01), whereas MAP and heart rate (HR) remained unchanged. However, no significant difference was detected between pre-ANH and post-ANH baroreflex sensitivities in either group. Our results indicate that arterial baroreflex control of HR is preserved during ANH to a hemoglobin concentration of 4-5 g/dL in anesthetized dogs. Acute normovolemic hemodilution may be preoperatively used to minimize the requirement of allogeneic blood products during major surgery. We found that baroreflex function is preserved during mild (hemoglobin concentration, 7-8 g/dL) and profound hemodilution (hemoglobin concentration, 4-5 g/dL) in pentobarbital-anesthetized dogs.
- 1 January 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (1) , 28-32
Hemodilution Does Not Alter Arterial Baroreflex Control of Heart Rate in Anesthetized Dogs
The cardiovascular effects of acute normovolemic hemodilution (ANH) are characterized by increased cardiac output and decreased systemic vascular resistance. However, whether arterial baroreflex function is altered by ANH remains undetermined. We assigned 23 anesthetized, mechanically ventilated dogs to mild ANH (hemoglobin, 7-8 g/dL; n = 11) or profound ANH (hemoglobin, 4-5 g/dL; n = 12) achieved by phlebotomy and simultaneous exchange with lactated Ringer's solution at 1:3 ratio to maintain constant central venous pressure and pulmonary artery occluded pressure. Baroreflex sensitivity was assessed by measurements of RR intervals of the electrocardiogram and mean arterial blood pressure (MAP) through a femoral artery catheter. Baroreflex responses were triggered by bolus IV injections of phenylephrine (25-75 micro g) and nitroprusside (50-100 micro g). The linear portion of the baroreflex curves relating RR intervals and MAP were used to determine baroreflex sensitivities. Compared with the predilution period, both ANH groups had significant increases in cardiac output and decreases in systemic vascular resistance (P < 0.01), whereas MAP and heart rate (HR) remained unchanged. However, no significant difference was detected between pre-ANH and post-ANH baroreflex sensitivities in either group. Our results indicate that arterial baroreflex control of HR is preserved during ANH to a hemoglobin concentration of 4-5 g/dL in anesthetized dogs. Acute normovolemic hemodilution may be preoperatively used to minimize the requirement of allogeneic blood products during major surgery. We found that baroreflex function is preserved during mild (hemoglobin concentration, 7-8 g/dL) and profound hemodilution (hemoglobin concentration, 4-5 g/dL) in pentobarbital-anesthetized dogs.
- 1 November 2002
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 95 (5) , 1408-1411
Does the Choice of Electrocardiography Lead Affect the Efficacy of the T-Wave Criterion for Detecting Intravascular Injection of an Epinephrine Test Dose?
Accidental intravascular injection of an epinephrine-containing test dose decreases the T-wave amplitude of a Lead II electrocardiogram (EKG) with 100% sensitivity and specificity on the basis of the T-wave criterion (positive if there is a ≥25% decrease in amplitude). We designed this study to test whether the choice of EKG lead would affect the efficacy of the simulated intravascular test dose in anesthetized patients. After an 8-h fast and no premedication, 35 healthy patients were anesthetized with end-tidal 2% sevoflurane and nitrous oxide after endotracheal intubation. When hemodynamic stability was obtained, all subjects received 3 mL of normal saline IV, followed 4 min later by 1.5% lidocaine 3 mL plus 15 μg of epinephrine (1:200,000) IV. Heart rate, systolic blood pressure, Leads II (n = 35) and V5 (n = 35), and either Lead I (n = 17) or III (n = 18), whichever had the greater T-wave amplitude, were continuously recorded for 4 min after the saline and test-dose injections. An IV test dose produced significant increases in heart rate and systolic blood pressure and produced decreases in the T-wave amplitude of all EKG leads studied in all subjects, whereas IV saline elicited no changes in these variables. The maximum percentage decreases in T-wave amplitude of Leads II, I, III, and V5 were −87% ± 13%, −88% ± 8%, −94% ± 15%, and −86% ± 16%, respectively (mean ± sd;P > 0.05). There was no significant difference in temporal changes in T-wave amplitude among the 4 leads, and sensitivity and specificity were 100% on the basis of the T-wave criterion, irrespective of the lead examined. Our results indicate that Leads II, I, III, and V5 of the EKG are equally effective for detecting intravascular injection of the epinephrine-containing test dose in sevoflurane-anesthetized adults.
- 1 November 2002
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 95 (5) , 1408-1411
Does the Choice of Electrocardiography Lead Affect the Efficacy of the T-Wave Criterion for Detecting Intravascular Injection of an Epinephrine Test Dose?
Accidental intravascular injection of an epinephrine-containing test dose decreases the T-wave amplitude of a Lead II electrocardiogram (EKG) with 100% sensitivity and specificity on the basis of the T-wave criterion (positive if there is a ≥25% decrease in amplitude). We designed this study to test whether the choice of EKG lead would affect the efficacy of the simulated intravascular test dose in anesthetized patients. After an 8-h fast and no premedication, 35 healthy patients were anesthetized with end-tidal 2% sevoflurane and nitrous oxide after endotracheal intubation. When hemodynamic stability was obtained, all subjects received 3 mL of normal saline IV, followed 4 min later by 1.5% lidocaine 3 mL plus 15 μg of epinephrine (1:200,000) IV. Heart rate, systolic blood pressure, Leads II (n = 35) and V5 (n = 35), and either Lead I (n = 17) or III (n = 18), whichever had the greater T-wave amplitude, were continuously recorded for 4 min after the saline and test-dose injections. An IV test dose produced significant increases in heart rate and systolic blood pressure and produced decreases in the T-wave amplitude of all EKG leads studied in all subjects, whereas IV saline elicited no changes in these variables. The maximum percentage decreases in T-wave amplitude of Leads II, I, III, and V5 were −87% ± 13%, −88% ± 8%, −94% ± 15%, and −86% ± 16%, respectively (mean ± sd;P > 0.05). There was no significant difference in temporal changes in T-wave amplitude among the 4 leads, and sensitivity and specificity were 100% on the basis of the T-wave criterion, irrespective of the lead examined. Our results indicate that Leads II, I, III, and V5 of the EKG are equally effective for detecting intravascular injection of the epinephrine-containing test dose in sevoflurane-anesthetized adults.
- 1 December 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 93 (6) , 1612-1617
The Efficacy of Simulated Intravascular Test Dose in Sedated Patients
Sedation usually decreases the reliability of subjectively detecting an intravascular test dose, but the efficacies of objective hemodynamic and T-wave criteria remain undetermined. Sixty healthy patients were randomly assigned to receive IV midazolam in 1-mg increments until they were lightly sedated, fentanyl 2 μg/kg followed by incremental midazolam until they were similarly sedated, or no sedative (n = 20 each). Then, normal saline 3 mL was administered IV, followed 4 min later by 1.5% lidocaine 3 mL plus epinephrine 15 μg (1:200,000) in all subjects. Heart rate (HR), systolic blood pressure (SBP) measured by a radial arterial catheter, and lead II of the electrocardiogram were continuously recorded for 4 min after the saline and test dose injections. An IV test dose produced significant increases in HR and SBP and decreases in T-wave amplitude in all subjects. However, the mean maximum increase in HR in patients sedated with midazolam plus fentanyl (31 ± 14 bpm [mean ± sd]) was significantly less than in those administered midazolam alone or no sedative (42 ± 12 and 44 ± 10 bpm, respectively;P P
- 1 December 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 93 (6) , 1612-1617
The Efficacy of Simulated Intravascular Test Dose in Sedated Patients
Sedation usually decreases the reliability of subjectively detecting an intravascular test dose, but the efficacies of objective hemodynamic and T-wave criteria remain undetermined. Sixty healthy patients were randomly assigned to receive IV midazolam in 1-mg increments until they were lightly sedated, fentanyl 2 μg/kg followed by incremental midazolam until they were similarly sedated, or no sedative (n = 20 each). Then, normal saline 3 mL was administered IV, followed 4 min later by 1.5% lidocaine 3 mL plus epinephrine 15 μg (1:200,000) in all subjects. Heart rate (HR), systolic blood pressure (SBP) measured by a radial arterial catheter, and lead II of the electrocardiogram were continuously recorded for 4 min after the saline and test dose injections. An IV test dose produced significant increases in HR and SBP and decreases in T-wave amplitude in all subjects. However, the mean maximum increase in HR in patients sedated with midazolam plus fentanyl (31 ± 14 bpm [mean ± sd]) was significantly less than in those administered midazolam alone or no sedative (42 ± 12 and 44 ± 10 bpm, respectively;P P
- 1 November 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 93 (5) , 1332-1337
T-Wave Amplitude as an Indicator for Detecting Intravascular Injection of Epinephrine Test Dose in Awake and Anesthetized Elderly Patients
Aging is associated with reduced heart rate (HR) responsiveness to a simulated IV test dose containing epinephrine. We tested the hypothesis that a more contemporary T-wave criterion (positive if there was a ≥25% decrease in T-wave amplitude) was applicable in both awake and anesthetized older patients. Sixteen healthy patients ≥65 yr old first received 3 mL of normal saline IV, followed 4 min later by 1.5% lidocaine 3 mL containing 15 μg epinephrine (1:200,000) IV in the supine position when awake, and they were anesthetized with stable 2% end-tidal sevoflurane and 67% nitrous oxide. HR, systolic blood pressure (SBP) determined invasively, and lead II of the electrocardiogram were continuously recorded for 4 min after the IV injections of saline and the test dose. A sensitivity of 88% and a negative predictive value of 89% were obtained in awake patients on the basis of the conventional HR criterion (positive if there was a ≥20 bpm increase), whereas a sensitivity of 81% and a negative predictive value of 84% were obtained during sevoflurane anesthesia on the basis of the modified HR criterion (positive if there was a ≥10 bpm increase). However, sen-sitivities, specificities, and positive and negative predictive values were all 100% on the basis of the SBP (positive if a ≥15 mm Hg increase was recorded with an arterial line) and the T-wave criteria for both awake and anesthetized conditions. These results suggest that the SBP and T-wave criteria should be applied in awake and anesthetized elderly patients for detecting accidental intravascular injection of the epinephrine-containing test dose.
- 1 November 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 93 (5) , 1332-1337
T-Wave Amplitude as an Indicator for Detecting Intravascular Injection of Epinephrine Test Dose in Awake and Anesthetized Elderly Patients
Aging is associated with reduced heart rate (HR) responsiveness to a simulated IV test dose containing epinephrine. We tested the hypothesis that a more contemporary T-wave criterion (positive if there was a ≥25% decrease in T-wave amplitude) was applicable in both awake and anesthetized older patients. Sixteen healthy patients ≥65 yr old first received 3 mL of normal saline IV, followed 4 min later by 1.5% lidocaine 3 mL containing 15 μg epinephrine (1:200,000) IV in the supine position when awake, and they were anesthetized with stable 2% end-tidal sevoflurane and 67% nitrous oxide. HR, systolic blood pressure (SBP) determined invasively, and lead II of the electrocardiogram were continuously recorded for 4 min after the IV injections of saline and the test dose. A sensitivity of 88% and a negative predictive value of 89% were obtained in awake patients on the basis of the conventional HR criterion (positive if there was a ≥20 bpm increase), whereas a sensitivity of 81% and a negative predictive value of 84% were obtained during sevoflurane anesthesia on the basis of the modified HR criterion (positive if there was a ≥10 bpm increase). However, sen-sitivities, specificities, and positive and negative predictive values were all 100% on the basis of the SBP (positive if a ≥15 mm Hg increase was recorded with an arterial line) and the T-wave criteria for both awake and anesthetized conditions. These results suggest that the SBP and T-wave criteria should be applied in awake and anesthetized elderly patients for detecting accidental intravascular injection of the epinephrine-containing test dose.
- 1 July 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 95 (1) , 51-55
Moderate Hypothermia Depresses Arterial Baroreflex Control of Heart Rate during, and Delays Its Recovery after, General Anesthesia in Humans
Background: Effects of hypothermia on arterial baroreflex function during, and on its recovery after, general anesthesia were examined in humans. Methods: Twenty healthy volunteers were randomly assigned to a normothermic group (n = 10 each, active forced-air warming) or to a hypothermic group (no active warming) during anesthesia. Measurements of R-R intervals and systolic blood pressure were made at conscious baseline and at 20, 60, and 120 min after the induction and 20, 60, 120, and 180 min after emergence from general anesthesia with sevoflurane for 2 h. Ventilation was mechanically controlled, and end-tidal sevoflurane concentration was maintained at 2% during anesthesia. Baroreflex responses were triggered by bolus intravenous injections of phenylephrine and nitroprusside. The linear portions of the baroreflex curves relating R-R intervals and systolic blood pressure were determined to obtain baroslopes. Results: During anesthesia, the mean lowest tympanic temperature of the hypothermia group (33.9+/-0.5 degrees C [mean +/- SD]) was significantly lower than that of the normothermia group (36.1+/-0.7 degrees C, P < 0.001). The baroslopes of the pressor and depressor tests were decreased by 19-39% during and by 27-53% after general anesthesia in the hypothermia group, compared with the normothermia group (P < 0.05). The baroslopes of the normothermia group returned to the baseline values at 60 min after anesthesia, whereas the pressor test sensitivity of the hypothermia group was significantly less than that of the normothermia group for the entire course of recovery. Conclusions: The results indicate that moderate hypothermia enhances anesthesia-induced depression of baroreflex function in anesthetized humans and delays its recovery after general anesthesia.
- 1 July 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 95 (1) , 51-55
Moderate Hypothermia Depresses Arterial Baroreflex Control of Heart Rate during, and Delays Its Recovery after, General Anesthesia in Humans
Background: Effects of hypothermia on arterial baroreflex function during, and on its recovery after, general anesthesia were examined in humans. Methods: Twenty healthy volunteers were randomly assigned to a normothermic group (n = 10 each, active forced-air warming) or to a hypothermic group (no active warming) during anesthesia. Measurements of R-R intervals and systolic blood pressure were made at conscious baseline and at 20, 60, and 120 min after the induction and 20, 60, 120, and 180 min after emergence from general anesthesia with sevoflurane for 2 h. Ventilation was mechanically controlled, and end-tidal sevoflurane concentration was maintained at 2% during anesthesia. Baroreflex responses were triggered by bolus intravenous injections of phenylephrine and nitroprusside. The linear portions of the baroreflex curves relating R-R intervals and systolic blood pressure were determined to obtain baroslopes. Results: During anesthesia, the mean lowest tympanic temperature of the hypothermia group (33.9+/-0.5 degrees C [mean +/- SD]) was significantly lower than that of the normothermia group (36.1+/-0.7 degrees C, P < 0.001). The baroslopes of the pressor and depressor tests were decreased by 19-39% during and by 27-53% after general anesthesia in the hypothermia group, compared with the normothermia group (P < 0.05). The baroslopes of the normothermia group returned to the baseline values at 60 min after anesthesia, whereas the pressor test sensitivity of the hypothermia group was significantly less than that of the normothermia group for the entire course of recovery. Conclusions: The results indicate that moderate hypothermia enhances anesthesia-induced depression of baroreflex function in anesthetized humans and delays its recovery after general anesthesia.
- 1 April 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 92 (4) , 915-917
Increased T-Wave Amplitude After Accidental Intravascular Injection of Lidocaine Plus Bupivacaine Without Epinephrine in Sevoflurane-Anesthetized Child
- 1 April 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 92 (4) , 915-917
Increased T-Wave Amplitude After Accidental Intravascular Injection of Lidocaine Plus Bupivacaine Without Epinephrine in Sevoflurane-Anesthetized Child
- 1 February 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 94 (2) , 365-367
Decrease in T-wave Amplitude without Hemodynamic Changes after Intravascular Injection of an Epinephrine Test Dose
- 1 February 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 94 (2) , 365-367
Decrease in T-wave Amplitude without Hemodynamic Changes after Intravascular Injection of an Epinephrine Test Dose