Adriano Giacomo Crismani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adriano Giacomo Crismani has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Georg Watzek
Professor and chair, Department of Oral Surgery; Austrian Cluster for Tissue Regeneration, Vienna, Austria
3 shared publicationsThomas Bernhart
Associate professor, Department of Oral Surgery, Medical University of Vienna, Vienna, Austria
3 shared publicationsHans-Peter Bantleon
Professor and chair, Department of Orthodontics, Medical University of Vienna, Vienna, Austria
2 shared publications- Stefan Tangl
Karl Donath Laboratory for Hard Tissue and Biomaterial Research, University Clinic of Dentistry, Medical University of Vienna, 1090 Vienna, Austria
2 shared publications Aleš G. Čelar
Associate professor, Department of Orthodontics, Medical University of Vienna, Vienna, Austria
1 shared publicationAleš Gaetano Čelar
Department of Orthodontics, Medical University of Vienna, Vienna, Austria
1 shared publication
Latest Publications
- 1 May 2008
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 133 (5) , 743-747
Osseointegration of a subperiosteal anchoring device in the minipig mandible
- 1 May 2008
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 133 (5) , 743-747
Osseointegration of a subperiosteal anchoring device in the minipig mandible
- 6 June 2006
- Published by Wiley in Clinical Oral Implants Research
- Vol. 17 (4) , 445-450
Ninety percent success in palatal implants loaded 1 week after placement: a clinical evaluation by resonance frequency analysis
Purpose: To investigate the behaviour of early loaded palatal implants when observed with resonance frequency analysis (RFA).Subject, material and methods: Twenty patients (seven males and 13 females, mean age 26.4 years) received one palatal implant each (length: 4 mm, diameter: 3.3 mm; Orthosystem®) for maximum orthodontic anchorage. The implants' stability was observed by RFA. Measurements were carried out at the time of surgery, after first orthodontic loading and subsequently once a week over a period of 12 weeks.Results: Two palatal implants were lost. The other 18 remained stable. The average period from insertion to first loading was 6.7±0.8 days. The mean orthodontic force applied was 272.2±73.2 cN. The implant stability quotient (ISQ) value at the time of surgery averaged 69.4±3.9. The mean ISQ value 6.7 days after insertion was 69.8±3.6. Twelve weeks post‐surgery the mean ISQ value was 69.8±3.5. A statistically significant decrease in stability was observed after 2 and 3 weeks post‐surgery (P=0.005 and 0.04).Conclusion: The behaviour of early loaded palatal implants showed an initial decrease of the ISQ values. From 6 weeks post‐surgery onward the ISQ values increased. Within the limitations of this study, the results suggest that the healing time of palatal implants reported in the literature (12 weeks) should be discussed. An orthodontic loading of palatal implants 6 weeks post‐surgery with a force up to 400 cN seems to be justified. Yet further investigations are necessary to evaluate the behaviour of early loaded palatal implants considering observation periods of over 12 weeks.
- 6 June 2006
- Published by Wiley in Clinical Oral Implants Research
- Vol. 17 (4) , 445-450
Ninety percent success in palatal implants loaded 1 week after placement: a clinical evaluation by resonance frequency analysis
Purpose: To investigate the behaviour of early loaded palatal implants when observed with resonance frequency analysis (RFA).Subject, material and methods: Twenty patients (seven males and 13 females, mean age 26.4 years) received one palatal implant each (length: 4 mm, diameter: 3.3 mm; Orthosystem®) for maximum orthodontic anchorage. The implants' stability was observed by RFA. Measurements were carried out at the time of surgery, after first orthodontic loading and subsequently once a week over a period of 12 weeks.Results: Two palatal implants were lost. The other 18 remained stable. The average period from insertion to first loading was 6.7±0.8 days. The mean orthodontic force applied was 272.2±73.2 cN. The implant stability quotient (ISQ) value at the time of surgery averaged 69.4±3.9. The mean ISQ value 6.7 days after insertion was 69.8±3.6. Twelve weeks post‐surgery the mean ISQ value was 69.8±3.5. A statistically significant decrease in stability was observed after 2 and 3 weeks post‐surgery (P=0.005 and 0.04).Conclusion: The behaviour of early loaded palatal implants showed an initial decrease of the ISQ values. From 6 weeks post‐surgery onward the ISQ values increased. Within the limitations of this study, the results suggest that the healing time of palatal implants reported in the literature (12 weeks) should be discussed. An orthodontic loading of palatal implants 6 weeks post‐surgery with a force up to 400 cN seems to be justified. Yet further investigations are necessary to evaluate the behaviour of early loaded palatal implants considering observation periods of over 12 weeks.
- 21 April 2005
- Vol. 20 (2) , 267-73
Nasal cavity perforation by palatal implants: false-positive records on the lateral cephalogram.
Lateral cephalometric films were examined for their validity as a tool for the postoperative evaluation of palatal implant placement. Cephalometric and histometric data of 20 partially edentulous human cadaveric maxillae were compared. Lateral cephalograms of the specimens were made, and the palatal complex was pencil traced. In addition, low-dose dental computerized tomography (CT) scans were obtained from every specimen. Based on the CT data, palatal implants (Orthosystem; Institut Straumann, Waldenburg, Switzerland) were placed. Postimplantation, another lateral cephalometric film was recorded. The specimens were prepared for histologic examination. The preoperative tracings were superimposed on the postoperative cephalometric films. Of 20 implants placed, 12 were 4 mm long and 8 were 6 mm long. The distance between the cranial end of the implants and the nasal floor on microscopy ranged from 0.3 to 9.3 mm. Perforation of the nasal floor was absent throughout on intraoperative probing, while 2 implants projected beyond the nasal floor on histologic analysis of the specimens. An analysis of the superimposed pre- and postoperative cephalograms showed 5 implants projecting beyond the nasal floor. Histologically, only 1 of these projecting implants had actually caused perforation of the palatal complex. A comparison between the histometric and the cephalometric data showed that cephalometry, on average, imaged the palatal complex 0.8 mm below the actual anatomic site. Twenty percent of palatal implants projecting beyond the nasal floor were false-positive records on the postoperative lateral cephalograms. Despite CT scans, 10% of the implants placed caused fenestration of the nasal cavity by histologic evidence. If the palatal complex was perforated, intraoperative probing with a periodontal probe did not confirm the perforation. Bone perforations up to 1.3 mm did not necessarily result in frank perforation of the nasal mucosa. Two-dimensional images could not be related to actual penetrations into the nasal cavity.
- 21 April 2005
- Vol. 20 (2) , 267-73
Nasal cavity perforation by palatal implants: false-positive records on the lateral cephalogram.
Lateral cephalometric films were examined for their validity as a tool for the postoperative evaluation of palatal implant placement. Cephalometric and histometric data of 20 partially edentulous human cadaveric maxillae were compared. Lateral cephalograms of the specimens were made, and the palatal complex was pencil traced. In addition, low-dose dental computerized tomography (CT) scans were obtained from every specimen. Based on the CT data, palatal implants (Orthosystem; Institut Straumann, Waldenburg, Switzerland) were placed. Postimplantation, another lateral cephalometric film was recorded. The specimens were prepared for histologic examination. The preoperative tracings were superimposed on the postoperative cephalometric films. Of 20 implants placed, 12 were 4 mm long and 8 were 6 mm long. The distance between the cranial end of the implants and the nasal floor on microscopy ranged from 0.3 to 9.3 mm. Perforation of the nasal floor was absent throughout on intraoperative probing, while 2 implants projected beyond the nasal floor on histologic analysis of the specimens. An analysis of the superimposed pre- and postoperative cephalograms showed 5 implants projecting beyond the nasal floor. Histologically, only 1 of these projecting implants had actually caused perforation of the palatal complex. A comparison between the histometric and the cephalometric data showed that cephalometry, on average, imaged the palatal complex 0.8 mm below the actual anatomic site. Twenty percent of palatal implants projecting beyond the nasal floor were false-positive records on the postoperative lateral cephalograms. Despite CT scans, 10% of the implants placed caused fenestration of the nasal cavity by histologic evidence. If the palatal complex was perforated, intraoperative probing with a periodontal probe did not confirm the perforation. Bone perforations up to 1.3 mm did not necessarily result in frank perforation of the nasal mucosa. Two-dimensional images could not be related to actual penetrations into the nasal cavity.