SHShahid M. Hussain

Shahid M. Hussain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shahid M. Hussain has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cirrhosis and Lesion Characterization at MR Imaging

    by Shahid M. Hussain, Caroline Reinhold, Donald G. Mitchell

    Magnetic resonance (MR) imaging has emerged as an important imaging modality for the assessment of cirrhosis and its complications. Faster sequences now allow high-quality liver imaging with high intrinsic soft-tissue contrast. Automated contrast detection methods in combination with faster sequences allow reproducible capture of the arterial phase, which is essential for the detection and characterization of hepatocellular carcinoma. The lack of ionizing radiation permits routine use of gadolinium-enhanced three-dimensional (3D) fat-suppressed multiphasic imaging with high temporal and spatial resolution. In addition, MR imaging allows simultaneous evaluation of the background liver parenchyma and the liver lesions with the combined use of sequences that include T2-weighted sequences, T1-weighted sequences (including chemical shift imaging), echoplanar diffusion-weighted sequences, dynamic gadolinium-enhanced 3D multiphasic imaging, and liver-specific delayed phase sequences (if contrast agents with hepatobiliary excretion are used). The combination of findings from different sequences often helps pinpoint the nature of the liver abnormalities.


  • Magnetic Resonance Imaging of Liver Lesions: Exceptions and Atypical Lesions

    by Indra C. van Den Bos, Shahid M. Hussain, Robert A. de Man, Pieter E. Zondervan, Jan N.M. Ijzermans, A. Preda, Gabriel P. Krestin


  • Primary Hepatocellular Lesions: Imaging Findings on State-of-the-Art Magnetic Resonance Imaging, with Pathologic Correlation

    by Indra C. van Den Bos, Shahid M. Hussain, Robert A. de Man, Pieter E. Zondervan, Jan N.M. Ijzermans, Gabriel P. Krestin


  • MR Imaging of the Female Pelvis at 3T

    by Shahid M. Hussain, Indra C. van Den Bos, Jennifer M. Oliveto, Diego R. Martin


  • Open Access

    Focal nodular hyperplasia: Lesion characteristics on state‐of‐the‐art MRI including dynamic gadolinium‐enhanced and superparamagnetic iron‐oxide‐uptake sequences in a prospective study

    by Türkan Terkivatan, Indra C. van Den Bos, Shahid M. Hussain, Piotr A. Wielopolski, Rob A. de Man, Jan N.M. Ijzermans

    Purpose: To image a cohort of patients with pathology‐proven focal nodular hyperplasia (FNH) to assess which characteristics of state‐of‐the‐art magnetic resonance imaging (MRI) of the liver are the most useful for improving the detection and characterization of FNH.Materials and Methods: In 14 patients, pathology‐proven FNH (N = 33) were prospectively examined using gadolinium (Gd) and superparamagnetic iron‐oxide (SPIO) contrast media. All lesions were evaluated for signal intensity (SI), fatty infiltration, central scar, mode of enhancement with Gd, and uptake of SPIO. The percentage of dynamic contrast enhancement in the arterial, portal, and delayed phases was assessed. The contrast‐to‐noise ratio (CNR) before and after administration of SPIO contrast was calculated.Results: The SI of the lesions was low to isointense on T1‐weighted (T1W) images, and intermediate to isointense on T2W images. Fatty infiltration of the lesions was present in 6%. The percentages of enhancement in the liver and lesion were 110%, 115%, and 95%, and 151%, 182%, and 160%, respectively (P < 0.0001). All lesions showed uptake of SPIO with improved conspicuity of the central scar and septa. The CNR values precontrast and post‐Gd/SPIO were significantly different for T1 in‐ and opposed‐phase and black‐blood echo‐planar imaging (BBEPI).Conclusion: Combining dynamic Gd‐enhanced imaging with T1W and T2W sequences after administration of SPIO facilitates comprehensive evaluation of FNH. J. Magn. Reson. Imaging 2006.


  • Hepatocellular adenoma: findings at state-of-the-art magnetic resonance imaging, ultrasound, computed tomography and pathologic analysis

    by Shahid M. Hussain, Indra C. van Den Bos, Roy S. Dwarkasing, Jan-Willem Kuiper, Jan Den Hollander

    The purpose of this paper is to describe the most recent concepts and pertinent findings of hepatocellular adenomas, including clinical presentation, gross pathology and histology, pathogenesis and transformation into hepatocellular carcinoma (HCC), and imaging findings at ultrasound (US), computed tomography (CT), and magnetic resonance (MR) imaging.


  • Contrast-Enhanced MR Angiography and Digital Subtraction Angiography in Living Renal Donors: Diagnostic Agreement, Impact on Decision Making, and Costs

    by Marc C. J. M. Kock, Jan N. M. Ijzermans, Karen Visser, Shahid M. Hussain, Willem Weimar, Peter M. T. Pattynama, Gabriel P. Krestin, M. G. Myriam Hunink

    OBJECTIVE. The objective of our study was to evaluate the diagnostic agreement, the impact on decision making, and the costs of contrast-enhanced MR angiography and digital subtraction angiography in the workup of living renal donors. CONCLUSION. Contrast-enhanced MR angiography for the preoperative evaluation of renal donors is superior to digital subtraction angiography in revealing vascular anomalies and depicting parenchymal abnormalities and is less costly; furthermore, it does not lead to preoperative decisions that differ from those based on digital subtraction angiography. If contrast-enhanced MR angiography does not provide sufficient information to make a confident decision, an additional digital subtraction angiography examination should be performed.


  • Abdominal Magnetic Resonance Imaging at 3.0 T

    by Shahid M. Hussain, Piotr A. Wielopolski, Diego R. Martin

    The development of transmit-receive body coils and local and phased-array radiofrequency receive coils for 3.0-T magnetic resonance imaging (MRI) systems, and their recent approval in Europe and North America has promoted a move toward higher field, whole-body MRI. With approximately double the signal-noise ratio of a 1.5-T system, 3.0-T MR systems can substantially improve image quality and image acquisition speed; 3.0 T can potentially deliver square root(2) improvement in resolution in the same acquisition time of a comparable study at 1.5 T or one-half slice thickness with identical coverage or 4-fold speedup in scanning time for identical resolution settings. Parallel imaging, multiple coil elements, specific absorption rate, and altered MR physical properties at 3.0 T (T1 relaxation times, susceptibility, T2*) are important issues during optimization of sequences at high field. Possible future applications in the abdomen include high-resolution, contrast-enhanced imaging of the liver and pancreas; MR angiography; and MR spectroscopy. In this article, we will present our initial experience with optimization of sequences for abdominal MRI at 3.0 T and will include a short description of parallel imaging because of its importance for imaging at 3.0 T, general remarks comparing some of the physical properties of 1.5 T and 3.0 T, and some of the challenges during sequence optimization for the abdomen at 3.0 T with examples of abdominal MRI at 3.0 T with 4- and 8-channel coils.


  • MR Imaging: A “One-Stop Shop” Modality for Preoperative Evaluation of Potential Living Kidney Donors

    by Shahid M. Hussain, Marc C. J. M. Kock, Jan N. M. Ijzermans, Peter M. T. Pattynama, M. G. Myriam Hunink, Gabriel P. Krestin

    At many institutions, magnetic resonance (MR) angiography is the technique of choice for assessment of the renal arteries and renal parenchyma in potential living kidney donors. The renal arteries and renal veins have a varied anatomy and may consist of one or more vessels at several levels with variable calibers and levels of branching. These findings may play an important role in the surgeon’s decision about which kidney to harvest, especially if laparoscopic nephrectomy is used. A comprehensive MR imaging protocol is used at one hospital to assess the arteries, veins, parenchyma, and collecting system of the kidneys. The protocol includes T2-weighted single-shot fast spin-echo imaging, fat-saturated T2-weighted fast spin-echo imaging, three-dimensional MR angiography and MR venography, and delayed fat-saturated three-dimensional T1-weighted gradient-echo imaging. Meticulous assessment of the source images as well as images produced with various postprocessing methods, such as full maximum intensity projection, targeted maximum intensity projection, and axial and oblique reformation, allows detailed description of the vascular anatomy and its relationship to the collecting system and parenchyma to facilitate the surgeon’s decision making. The findings of MR imaging are comparable with those of other imaging modalities. © RSNA, 2003