Gustavo A. Rivas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gustavo A. Rivas has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- María D. Rubianes
INFIQC, Departamento de Físico Química, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina phone: +54-351-4334169/80; fax: +54-351-4334188
8 shared publications Marcela C. Rodríguez
INFIQC, Departamento de Físico Química, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina
4 shared publicationsNancy F. Ferreyra
INFIQC. Departamento de Físico Química. Facultad de Ciencias Químicas, Universidad Nacional de Córdoba. 5000, Córdoba, Argentina
3 shared publicationsPilar Herrasti
Departamento de Química Física Aplicada, Facultad de Ciencias, Universidad Autónoma de Madrid, SSIC, 28049, Cantoblanco, Madrid, España
3 shared publicationsFausto N. Comba
INFIQC, Departamento de Físico Química, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina
2 shared publications- Guillermina Leticia Luque
Department of Physical Chemistry, Faculty of Chemical Sciences, National University of Córdoba (UNC), Córdoba, Argentina
2 shared publications
Latest Publications
- 21 March 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (5) , 1135-1142
Adsorption and Electrooxidation of DNA at Glassy Carbon Electrodes Modified with Multiwall Carbon Nanotubes Dispersed in Glucose Oxidase
We are proposing for the first time the successful immobilization of DNA at glassy carbon electrodes (GCE) modified with carbon nanotubes (CNT) dispersed in glucose oxidase (GOx) (GCE/CNT‐GOx) either by direct adsorption or by layer‐by‐layer self‐assembling using polydiallyldimethylamine (PDDA). The presence of GOx allows an efficient dispersion of CNT and gives a most favorable environment that promotes the adsorption and makes possible a more sensitive electrooxidation of DNA. The PDDA incorporated in the self‐assembled architecture largely facilitates the adsorption and electrooxidation of dsDNA and the adsorbed layer can be successfully used for evaluating the interaction of DNA with methylene blue.
- 21 March 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (5) , 1135-1142
Adsorption and Electrooxidation of DNA at Glassy Carbon Electrodes Modified with Multiwall Carbon Nanotubes Dispersed in Glucose Oxidase
We are proposing for the first time the successful immobilization of DNA at glassy carbon electrodes (GCE) modified with carbon nanotubes (CNT) dispersed in glucose oxidase (GOx) (GCE/CNT‐GOx) either by direct adsorption or by layer‐by‐layer self‐assembling using polydiallyldimethylamine (PDDA). The presence of GOx allows an efficient dispersion of CNT and gives a most favorable environment that promotes the adsorption and makes possible a more sensitive electrooxidation of DNA. The PDDA incorporated in the self‐assembled architecture largely facilitates the adsorption and electrooxidation of dsDNA and the adsorbed layer can be successfully used for evaluating the interaction of DNA with methylene blue.
- 5 March 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (5) , 1116-1121
Adsorption and Electrooxidation of Nucleic Acids at Glassy Carbon Electrodes Modified with Multiwalled Carbon Nanotubes Dispersed In Polylysine
- 5 March 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (5) , 1116-1121
Adsorption and Electrooxidation of Nucleic Acids at Glassy Carbon Electrodes Modified with Multiwalled Carbon Nanotubes Dispersed In Polylysine
- 31 August 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (22) , 2650-2657
Quantification of Quercetin Using Glassy Carbon Electrodes Modified with Multiwalled Carbon Nanotubes Dispersed in Polyethylenimine and Polyacrylic Acid
This work reports the highly sensitive detection of quercetin using glassy carbon electrodes modified with multiwall carbon nanotubes (MWCNT) dispersed in polyethylenimine and poly(acrylic acid). The adsorptive stripping with square wave voltammetric transduction allowed the detection of 7.5 nM quercetin after 1.0 min accumulation at open circuit potential. The amperometric detection at 0.150 V is reported as an easier and simpler alternative to determine quercetin, with detection limits of 0.2 µM. The careful selection of the working conditions also made possible the detection of submicromolar levels of quercetin in the presence of excess of rutin. The proposed methodology was successfully used to quantify quercetin in onion samples.
- 31 August 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (22) , 2650-2657
Quantification of Quercetin Using Glassy Carbon Electrodes Modified with Multiwalled Carbon Nanotubes Dispersed in Polyethylenimine and Polyacrylic Acid
This work reports the highly sensitive detection of quercetin using glassy carbon electrodes modified with multiwall carbon nanotubes (MWCNT) dispersed in polyethylenimine and poly(acrylic acid). The adsorptive stripping with square wave voltammetric transduction allowed the detection of 7.5 nM quercetin after 1.0 min accumulation at open circuit potential. The amperometric detection at 0.150 V is reported as an easier and simpler alternative to determine quercetin, with detection limits of 0.2 µM. The careful selection of the working conditions also made possible the detection of submicromolar levels of quercetin in the presence of excess of rutin. The proposed methodology was successfully used to quantify quercetin in onion samples.
- 6 August 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 149 (1) , 306-309
Glucose biosensing at carbon paste electrodes containing iron nanoparticles
- 6 August 2010
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 149 (1) , 306-309
Glucose biosensing at carbon paste electrodes containing iron nanoparticles
- 9 July 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (14) , 1566-1572
Highly Sensitive and Selective Glucose Biosensing at Carbon Paste Electrodes Modified with Electrogenerated Magnetite Nanoparticles and Glucose Oxidase
This work reports the advantages of carbon paste electrodes modified with electrogenerated magnetite nanoparticles. The nanoparticles present catalytic activity towards hydrogen peroxide reduction. The incorporation of glucose oxidase (GOx) and magnetite in a carbon paste matrix have made possible the development of an efficient glucose biosensor. The effect of the amount of GOx and magnetite present in the composite on the response of the biosensor was critically evaluated. The biosensors demonstrated to be highly selective, with negligible interference of ascorbic acid and uric acid. The proposed biosensor was challenged with human blood serum demonstrating an excellent correlation with the spectrophotometric method.
- 9 July 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (14) , 1566-1572
Highly Sensitive and Selective Glucose Biosensing at Carbon Paste Electrodes Modified with Electrogenerated Magnetite Nanoparticles and Glucose Oxidase
This work reports the advantages of carbon paste electrodes modified with electrogenerated magnetite nanoparticles. The nanoparticles present catalytic activity towards hydrogen peroxide reduction. The incorporation of glucose oxidase (GOx) and magnetite in a carbon paste matrix have made possible the development of an efficient glucose biosensor. The effect of the amount of GOx and magnetite present in the composite on the response of the biosensor was critically evaluated. The biosensors demonstrated to be highly selective, with negligible interference of ascorbic acid and uric acid. The proposed biosensor was challenged with human blood serum demonstrating an excellent correlation with the spectrophotometric method.
- 23 December 2009
- Published by Wiley in Electroanalysis
- Vol. 22 (1) , 128-134
Amperometric Response of Hydrogen Peroxide at Carbon Nanotubes Paste Electrodes Modified with an Electrogenerated Poly(Fe(III)‐5‐amino‐phenantroline). Analytical Applications for Glucose Biosensing
This work reports the catalytic activity of a polymer electrogenerated from Fe(III)‐5‐amino‐1,10‐phenantroline solution at a carbon nanotubes paste electrode (CNTPE) towards the oxidation and mainly the reduction of hydrogen peroxide. The important role of carbon nanotubes on the generation of poly(Fe(III)‐5‐amino‐1,10‐phenantroline) is demonstrated through the comparison with the behavior of graphite paste electrode (CPE). The polymer electrogenerated at CNTPE largely improves the amperometric detection of hydrogen peroxide at −0.100 V. The analytical application of the resulting electrode is demonstrated in connection with the design of a glucose biosensor based on the deposition of GOx and diluted Nafion on the top of the polymer‐modified CNTPE. The quantification of glucose in human serum samples showed a good correlation with the values obtained by the spectrophotometric technique.
- 23 December 2009
- Published by Wiley in Electroanalysis
- Vol. 22 (1) , 128-134
Amperometric Response of Hydrogen Peroxide at Carbon Nanotubes Paste Electrodes Modified with an Electrogenerated Poly(Fe(III)‐5‐amino‐phenantroline). Analytical Applications for Glucose Biosensing
This work reports the catalytic activity of a polymer electrogenerated from Fe(III)‐5‐amino‐1,10‐phenantroline solution at a carbon nanotubes paste electrode (CNTPE) towards the oxidation and mainly the reduction of hydrogen peroxide. The important role of carbon nanotubes on the generation of poly(Fe(III)‐5‐amino‐1,10‐phenantroline) is demonstrated through the comparison with the behavior of graphite paste electrode (CPE). The polymer electrogenerated at CNTPE largely improves the amperometric detection of hydrogen peroxide at −0.100 V. The analytical application of the resulting electrode is demonstrated in connection with the design of a glucose biosensor based on the deposition of GOx and diluted Nafion on the top of the polymer‐modified CNTPE. The quantification of glucose in human serum samples showed a good correlation with the values obtained by the spectrophotometric technique.
- 23 July 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (15) , 1623-1631
Glassy Carbon Electrodes Modified with Multiwall Carbon Nanotubes Dispersed in Polylysine
We report the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multiwall carbon nanotubes (MWCNT) in polylysine (Plys) (GCE/MWCNT‐Plys). The resulting electrodes show an excellent electrocatalytic activity towards different bioanalytes like ascorbic acid, uric acid and hydrogen peroxide, with important decrease in their oxidation overvoltages. The dispersion of 1.0 mg/mL MWCNT in 1.0 mg/mL polylysine is highly stable, since after 2 weeks the sensitivity for hydrogen peroxide at GCE modified with this dispersion remained in a 90% of the original value. The MWCNT‐Plys layer immobilized on glassy carbon electrodes has been also used as a platform to build supramolecular architectures by self‐assembling of polyelectrolytes based on the polycationic nature of the polylysine used to disperse the nanotubes. The self‐assembling of glucose oxidase has allowed us to obtain a supramolecular multistructure for glucose biosensing. The influence of glucose oxidase concentration and adsorption time as well as the effect of using polylysine or MWCNT‐Plys as polycationic layers for further adsorption of GOx is also evaluated.
- 23 July 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (15) , 1623-1631
Glassy Carbon Electrodes Modified with Multiwall Carbon Nanotubes Dispersed in Polylysine
We report the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multiwall carbon nanotubes (MWCNT) in polylysine (Plys) (GCE/MWCNT‐Plys). The resulting electrodes show an excellent electrocatalytic activity towards different bioanalytes like ascorbic acid, uric acid and hydrogen peroxide, with important decrease in their oxidation overvoltages. The dispersion of 1.0 mg/mL MWCNT in 1.0 mg/mL polylysine is highly stable, since after 2 weeks the sensitivity for hydrogen peroxide at GCE modified with this dispersion remained in a 90% of the original value. The MWCNT‐Plys layer immobilized on glassy carbon electrodes has been also used as a platform to build supramolecular architectures by self‐assembling of polyelectrolytes based on the polycationic nature of the polylysine used to disperse the nanotubes. The self‐assembling of glucose oxidase has allowed us to obtain a supramolecular multistructure for glucose biosensing. The influence of glucose oxidase concentration and adsorption time as well as the effect of using polylysine or MWCNT‐Plys as polycationic layers for further adsorption of GOx is also evaluated.
- 12 April 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 833-840
Electrooxidation of DNA at Glassy Carbon Electrodes Modified with Multiwall Carbon Nanotubes Dispersed in Chitosan
We report on the analytical performance of glassy carbon (GCE) electrodes modified with a dispersion of multiwall carbon nanotubes (CNT) in chitosan (CHIT) for the quantification of DNA. The electroanalytical response of the resulting electrodes was evaluated using differential pulse voltammetry, while the electrochemical reactivity of the film surface was characterized using scanning electrochemical microscopy. Different treatments of the modified GCE were evaluated to improve the stability of the film and the accumulation of DNA. The guanine oxidation signal of double stranded calf‐thymus DNA after 3‐min accumulation was 20 times higher at GCE/CHIT‐CNT cross‐linked with glutaraldehyde (GTA) than at bare GCE, while the peak potential was around 45 mV less positive. The guanine oxidation signal demonstrated to be highly reproducible, with 3.4% RSD for 5 different electrodes. The treatment with sodium hydroxide demonstrated to be not effective since the resulting films were less stable and the guanine oxidation signal was ten times smaller compared to electrodes prepared with the GTA treated films. The effect of chitosan molecular weight used to prepare the dispersion and the amount of carbon nanotubes dispersed were evaluated. The response of single stranded DNA and oligo(dG)15 is also discussed.
- 12 April 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 833-840
Electrooxidation of DNA at Glassy Carbon Electrodes Modified with Multiwall Carbon Nanotubes Dispersed in Chitosan
We report on the analytical performance of glassy carbon (GCE) electrodes modified with a dispersion of multiwall carbon nanotubes (CNT) in chitosan (CHIT) for the quantification of DNA. The electroanalytical response of the resulting electrodes was evaluated using differential pulse voltammetry, while the electrochemical reactivity of the film surface was characterized using scanning electrochemical microscopy. Different treatments of the modified GCE were evaluated to improve the stability of the film and the accumulation of DNA. The guanine oxidation signal of double stranded calf‐thymus DNA after 3‐min accumulation was 20 times higher at GCE/CHIT‐CNT cross‐linked with glutaraldehyde (GTA) than at bare GCE, while the peak potential was around 45 mV less positive. The guanine oxidation signal demonstrated to be highly reproducible, with 3.4% RSD for 5 different electrodes. The treatment with sodium hydroxide demonstrated to be not effective since the resulting films were less stable and the guanine oxidation signal was ten times smaller compared to electrodes prepared with the GTA treated films. The effect of chitosan molecular weight used to prepare the dispersion and the amount of carbon nanotubes dispersed were evaluated. The response of single stranded DNA and oligo(dG)15 is also discussed.
- 12 April 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 823-831
Carbon Nanotubes Paste Electrodes. A New Alternative for the Development of Electrochemical Sensors
- 12 April 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 823-831
Carbon Nanotubes Paste Electrodes. A New Alternative for the Development of Electrochemical Sensors
- 1 May 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 115 (1) , 205-211
Glucose biosensors based on the immobilization of glucose oxidase and polytyramine on rodhinized glassy carbon and screen printed electrodes
- 1 May 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 115 (1) , 205-211
Glucose biosensors based on the immobilization of glucose oxidase and polytyramine on rodhinized glassy carbon and screen printed electrodes